{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T11:09:34Z","timestamp":1785841774824,"version":"3.56.0"},"reference-count":42,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2023,6,20]],"date-time":"2023-06-20T00:00:00Z","timestamp":1687219200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Artificial Organs"],"published-print":{"date-parts":[[2023,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>While cardiovascular system and mechanical circulatory support devices are efficiently model the effect of disease and assistance, they can also lend valuable insights into clinical procedures. This study demonstrates the use of a CVS\u2010VAD model for an invasive procedure; hemodynamic ramp testing, in\u2010silico.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The CVS model is developed using validated models in literature, using Simscape\u2122. An analytically derived pump model is calibrated for the HeartWare VAD. Dilated cardiomyopathy is used as an illustrative example of heart failure, and heart failure patients are created virtually by calibrating the model with requisite disease parameters obtained from published patient data. A clinically applied ramp study protocol is adopted whereby speed optimization is performed following clinically accepted hemodynamic normalization criteria. Trends in hemodynamic variables in response to pump speed increments are obtained. Optimal speed ranges are obtained for the three virtual patients based on target values of central venous pressure (CVP), pulmonary capillary wedge pressure (PCWP), cardiac output (CO), and mean arterial pressure (MAP) for hemodynamic stabilization.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Appreciable speed changes in the mild case (300\u2009rpm), slight changes in the moderate case (100\u2009rpm), and no changes in the simulated severe case are possible.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The study demonstrates a novel application of cardiovascular modeling using an open\u2010source acausal model, which can be potentially beneficial for medical education and research.<\/jats:p><\/jats:sec>","DOI":"10.1111\/aor.14597","type":"journal-article","created":{"date-parts":[[2023,6,12]],"date-time":"2023-06-12T09:45:24Z","timestamp":1686563124000},"page":"1452-1463","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["In\u2010silico hemodynamic ramp testing of ventricular assist device implanted patients using acausal cardiovascular\u2010VAD modeling"],"prefix":"10.1111","volume":"47","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5969-3823","authenticated-orcid":false,"given":"Khunsha","family":"Mehmood","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering Ko\u00e7 University  Istanbul Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Munam","family":"Arshad","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering Ko\u00e7 University  Istanbul Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8316-9623","authenticated-orcid":false,"given":"Ismail","family":"Lazoglu","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering Ko\u00e7 University  Istanbul Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deniz S\u00fcha","family":"K\u00fc\u00e7\u00fckaksu","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery Ba\u015fkent University Istanbul Health Application and Research Center  Istanbul Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vedat","family":"Bakuy","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery Ba\u015fkent University Istanbul Health Application and Research Center  Istanbul Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2023,6,20]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1186\/1475\u2010925X\u201010\u201033"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bbe.2017.03.003"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/aor.14220"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/aor.13569"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cma.2022.115473"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2016.07.008"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCHEARTFAILURE.119.006067"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2013.01.007"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1002\/adts.202000216"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/0010\u20104825(86)90002\u20108"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/0020\u20107101(88)90006\u20102"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525\u20101594.2006.00326.x"},{"key":"e_1_2_10_14_1","volume-title":"Cardiac contraction and the pressure\u2010volume relationship","author":"Sagawa K","year":"1988"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1152\/ajpheart.1982.243.1.H99"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jchf.2015.10.001"},{"key":"e_1_2_10_17_1","first-page":"33","volume-title":"Cardiovascular and pulmonary artificial organs: educational training simulators","author":"Capoccia M","year":"2017"},{"key":"e_1_2_10_18_1","volume-title":"Modeling and control of left ventricular assist system","author":"Choi S","year":"1998"},{"issue":"3","key":"e_1_2_10_19_1","first-page":"M252","article-title":"Computer simulation of the circulatory system during support with a rotary blood pump","volume":"36","author":"Schima H","year":"1990","journal-title":"ASAIO Trans"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2017.12.012"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/aor.12593"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598\u2010021\u201082567\u20109"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/0010\u20104825(93)90092\u2010f"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.94.1.52"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/0735\u20101097(94)90428\u20106"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(99)00362-9"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0114153"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1172\/jci115058"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002\u20109149(87)90376\u20106"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002\u20109149(85)90778\u20107"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.eurheartj.a061690"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1155\/2013\/235194"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1990.69.1.112"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1388\u20109842(03)00100\u20104"},{"key":"e_1_2_10_35_1","doi-asserted-by":"publisher","DOI":"10.1253\/circj.cj\u201009\u20100046"},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.1152\/ajpheart.1998.274.2.H500"},{"key":"e_1_2_10_37_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.13\u20101510"},{"key":"e_1_2_10_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2009.11.020"},{"key":"e_1_2_10_39_1","doi-asserted-by":"publisher","DOI":"10.1111\/jocs.15564"},{"key":"e_1_2_10_40_1","doi-asserted-by":"publisher","DOI":"10.1161\/HHF.0000000000000074"},{"key":"e_1_2_10_41_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.case.2020.05.015"},{"key":"e_1_2_10_42_1","doi-asserted-by":"publisher","DOI":"10.1097\/mat.0000000000000033"},{"key":"e_1_2_10_43_1","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.118.010232"}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/aor.14597","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,26]],"date-time":"2023-09-26T13:41:45Z","timestamp":1695735705000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/aor.14597"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,20]]},"references-count":42,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2023,9]]}},"alternative-id":["10.1111\/aor.14597"],"URL":"https:\/\/doi.org\/10.1111\/aor.14597","archive":["Portico"],"relation":{},"ISSN":["0160-564X","1525-1594"],"issn-type":[{"value":"0160-564X","type":"print"},{"value":"1525-1594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6,20]]},"assertion":[{"value":"2023-04-06","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-06-08","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-06-20","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}