{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T21:43:19Z","timestamp":1794692599343,"version":"4.9.1"},"reference-count":35,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2023,8,21]],"date-time":"2023-08-21T00:00:00Z","timestamp":1692576000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Artificial Organs"],"published-print":{"date-parts":[[2023,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>Short\u2010term continuous flow (STCF) ventricular assist devices (VADs) are utilized in adults with cardiogenic shock; however, mortality remains high. Previous studies have found that high pre\u2010operative MELD\u2010XI scores in durable VAD patients are associated with mortality. The use of the MELD\u2010XI score to predict outcomes in STCF\u2010VAD patients has not been explored. We sought to determine the relationship between MELD\u2010XI and outcomes in adults with STCF\u2010VADs.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This was a retrospective review of adults implanted with STCF\u2010VADs between 2009 and 2019. Receiver operating characteristic (ROC) analysis was performed to predict outcomes and Kaplan\u2013Meier analysis was done to assess survival.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Seventy\u2010nine patients were included with a median MELD\u2010XI score of 21.2 (IQR 13.5, 27.0). Patients with an unsuccessful wean from support (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001) or major post\u2010operative bleeding (<jats:italic>p<\/jats:italic>\u2009=\u20090.03) had significantly higher pre\u2010implant MELD\u2010XI scores. The optimal MELD\u2010XI cut\u2010point for mortality was 24.9 with 27.8 for major bleeding. Survival was worse among patients in the high\u2010risk MELD\u2010XI group, however, not statistically significant (<jats:italic>p<\/jats:italic>\u2009=\u20090.09). Prior ECMO support, but not MELD\u2010XI, was an independent predictor of unsuccessful wean (<jats:italic>p<\/jats:italic>\u2009=\u20090.03).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Pre\u2010operative MELD\u2010XI score was a moderate predictor of unsuccessful wean with limited utility in predicting bleeding in patients on STCF\u2010VAD support. This scoring system may be useful in the clinical setting for pre\u2010implant risk stratification and counseling among patients and outcomes.<\/jats:p><\/jats:sec>","DOI":"10.1111\/aor.14617","type":"journal-article","created":{"date-parts":[[2023,7,21]],"date-time":"2023-07-21T08:20:28Z","timestamp":1689927628000},"page":"1752-1761","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Predicting outcomes following short\u2010term ventricular assist device implant with the <scp>MELD\u2010XI<\/scp> score"],"prefix":"10.1111","volume":"47","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9471-8966","authenticated-orcid":false,"given":"Tara","family":"Pidborochynski","sequence":"first","affiliation":[{"name":"Department of Pediatric Cardiology University of Alberta  Edmonton Alberta Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sabin J.","family":"Bozso","sequence":"additional","affiliation":[{"name":"Division of Cardiac Surgery University of Alberta  Edmonton Alberta Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Holger","family":"Buchholz","sequence":"additional","affiliation":[{"name":"Division of Cardiac Surgery University of Alberta  Edmonton Alberta Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Darren H.","family":"Freed","sequence":"additional","affiliation":[{"name":"Division of Cardiac Surgery University of Alberta  Edmonton Alberta Canada"},{"name":"Division of Pediatric Cardiac Surgery Stollery Children's Hospital  Edmonton Alberta Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roderick","family":"MacArthur","sequence":"additional","affiliation":[{"name":"Division of Cardiac Surgery University of Alberta  Edmonton Alberta Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jennifer","family":"Conway","sequence":"additional","affiliation":[{"name":"Department of Pediatric Cardiology University of Alberta  Edmonton Alberta Canada"},{"name":"Division of Pediatric Cardiology Stollery Children's Hospital  Edmonton Alberta Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2023,8,21]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCHEARTFAILURE.113.000271"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12055-020-01060-6"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.5301\/ijao.5000488"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2010.03.046"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2011.12.016"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0b013e31821f2116"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2008.01.027"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5223(03)00727-X"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2006.02.056"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2005.08.019"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0000000000000902"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1053\/he.2000.5852"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1053\/jhep.2001.22172"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2012.12.056"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2012.02.008"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.108.838656"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2012.02.008"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/lt.20906"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0170987"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2018.02.082"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1177\/2048872615610865"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2012.02.027"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbi.2008.08.010"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbi.2019.103208"},{"key":"e_1_2_8_26_1","volume-title":"MELD\/PELD calculator documentation","author":"United Network for Organ Sharing (UNOS)","year":"2009"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2017.07.005"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.143.1.7063747"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.105.594929"},{"issue":"4","key":"e_1_2_8_30_1","first-page":"203","article-title":"Measures of diagnostic accuracy: basic definitions","volume":"19","author":"Simundic A\u2010M","year":"2009","journal-title":"EJIFCC"},{"issue":"10","key":"e_1_2_8_31_1","first-page":"YE01","article-title":"Requirements for minimum sample size for sensitivity and specificity analysis","volume":"10","author":"Bujang MA","year":"2016","journal-title":"J Clin Diagn Res"},{"key":"e_1_2_8_32_1","doi-asserted-by":"publisher","DOI":"10.1186\/s41512-020-00082-3"},{"key":"e_1_2_8_33_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0000000000000893"},{"key":"e_1_2_8_34_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-020-05939-1"},{"key":"e_1_2_8_35_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCHEARTFAILURE.119.006387"},{"key":"e_1_2_8_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2015.07.026"}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/aor.14617","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,14]],"date-time":"2023-11-14T13:43:34Z","timestamp":1699969414000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/aor.14617"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,21]]},"references-count":35,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2023,11]]}},"alternative-id":["10.1111\/aor.14617"],"URL":"https:\/\/doi.org\/10.1111\/aor.14617","archive":["Portico"],"relation":{},"ISSN":["0160-564X","1525-1594"],"issn-type":[{"value":"0160-564X","type":"print"},{"value":"1525-1594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,21]]},"assertion":[{"value":"2023-02-09","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-07-14","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-08-21","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}