{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,28]],"date-time":"2026-01-28T06:11:26Z","timestamp":1769580686886,"version":"3.49.0"},"reference-count":9,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2023,11,23]],"date-time":"2023-11-23T00:00:00Z","timestamp":1700697600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Artificial Organs"],"published-print":{"date-parts":[[2024,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Introduction<\/jats:title><jats:p>Extracorporeal membrane oxygenation (ECMO) is increasingly used for circulatory or pulmonary support not only in\u2010hospital but also out\u2010of\u2010hospital. Small dimensions and a lightweight design are important, especially for out\u2010of\u2010hospital use but also for intra\u2010hospital transportation of patients who require ECMO support. We share our first experience with the new Colibr\u00ec ECMO system.<\/jats:p><\/jats:sec><jats:sec><jats:title>Patients and Methods<\/jats:title><jats:p>From December 2022 to January 2023, we used the new Colibr\u00ec extracorporeal circulation (ECC) system in six patients with cardiac or pulmonary failure.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The Colibr\u00ec system was used in\u2010hospital in six patients with post\u2010cardiac surgery low output syndrome, respiratory failure due to influenza or acute respiratory distress syndrome, cardiogenic shock, pulmonary embolism, and failed weaning from cardiopulmonary bypass. The system was implanted in venovenous (VV) and venoarterial (VA) fashion in 3 patients, respectively. In one patient, the configuration was switched from VA to VV after cardiac recovery. One patient received left\u2010ventricular unloading using the IMPELLA\u00ae5.5. ECMO run time was 1 to 13\u2009days. We did not notice any ECC system\u2010associated complications. No ECMO system changes were required.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Our case series concludes that the new Colibr\u00ec system is safe and effective for in\u2010hospital ECMO indications. The small dimensions and lightweight design are very beneficial for the transportation of patients. It might be especially helpful for out\u2010of\u2010hospital situations.<\/jats:p><\/jats:sec>","DOI":"10.1111\/aor.14671","type":"journal-article","created":{"date-parts":[[2023,11,23]],"date-time":"2023-11-23T19:10:48Z","timestamp":1700766648000},"page":"103-109","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["First experience with the new extracorporeal membrane oxygenation system Colibr\u00ec"],"prefix":"10.1111","volume":"48","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1516-3286","authenticated-orcid":false,"given":"Lars","family":"Saemann","sequence":"first","affiliation":[{"name":"Department of Cardiac Surgery University Hospital Halle  Halle (Saale) Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Markus","family":"Stiller","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery University Hospital Halle  Halle (Saale) Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan","family":"Willsch","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery University Hospital Halle  Halle (Saale) Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Schultze","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery University Hospital Halle  Halle (Saale) Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Meradjoddin","family":"Matin","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery University Hospital Halle  Halle (Saale) Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G\u00e1bor","family":"Veres","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery University Hospital Halle  Halle (Saale) Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G\u00e1bor","family":"Szab\u00f3","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery University Hospital Halle  Halle (Saale) Germany"},{"name":"Department of Cardiac Surgery Heidelberg University Hospital  Heidelberg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2023,11,23]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1051\/ject\/202254191"},{"key":"e_1_2_9_3_1","article-title":"Extracorporeal membrane oxygenation in intoxication and overdoses: a systematic review","author":"Maier S","year":"2022","journal-title":"Thorac Cardiovasc Surg"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1510\/icvts.2010.264630"},{"key":"e_1_2_9_5_1","unstructured":"Eurosets.Colibr\u00ed system\u2014instructions for use. EU11042_ENG Rev.03.2022."},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13019-021-01637-1"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2012.01514.x"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.21037\/jtd.2019.04.05"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.xjon.2021.10.006"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-78709-0"}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/aor.14671","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,21]],"date-time":"2024-01-21T11:56:52Z","timestamp":1705838212000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/aor.14671"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,23]]},"references-count":9,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,1]]}},"alternative-id":["10.1111\/aor.14671"],"URL":"https:\/\/doi.org\/10.1111\/aor.14671","archive":["Portico"],"relation":{},"ISSN":["0160-564X","1525-1594"],"issn-type":[{"value":"0160-564X","type":"print"},{"value":"1525-1594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,23]]},"assertion":[{"value":"2023-06-19","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-10-12","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-11-23","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}