{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T16:10:54Z","timestamp":1790093454394,"version":"4.0.1"},"reference-count":27,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2024,9,14]],"date-time":"2024-09-14T00:00:00Z","timestamp":1726272000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2024,9,14]],"date-time":"2024-09-14T00:00:00Z","timestamp":1726272000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["31900944"],"award-info":[{"award-number":["31900944"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Artificial Organs"],"published-print":{"date-parts":[[2025,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The artificial anal sphincter is a device used to treat patients with fecal incontinence who are unable to control their bowel movements on their own. Long\u2010term morphological changes in the tissue surrounding the artificial anal sphincter can cause biomechanical compatibility problems, which seriously affect the clinical application of the artificial anal sphincter.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In this paper, the superelasticity of shape memory alloys was utilized to design and fabricate a biomechanically compatible constant force clamping artificial anal sphincter. An in\u00a0vitro simulation system was constructed to verify the effectiveness, safety, and constant force characteristics of the artificial anal sphincter.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The experimental results demonstrated that the artificial anal sphincter could be effectively closed with no leakage of the liquid\u2010like intestinal contents, which are most likely to leak. The pressure of the artificial anal sphincter on the intestinal tube gradually increased and eventually became constant during closure, and the pressure value was always less than the intestinal blood supply pressure threshold.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In this paper, we designed an artificial anal sphincter based on biomechanical compatibility and the corresponding in\u00a0vitro simulation experimental program and preliminarily verified the effectiveness, safety, and constant force characteristics of the artificial anal sphincter.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/aor.14863","type":"journal-article","created":{"date-parts":[[2024,9,14]],"date-time":"2024-09-14T04:30:18Z","timestamp":1726288218000},"page":"74-84","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Experimental evaluation of an artificial anal sphincter based on biomechanical compatibility"],"prefix":"10.1111","volume":"49","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2957-3211","authenticated-orcid":false,"given":"Minghui","family":"Wang","sequence":"first","affiliation":[{"name":"Institute of Rehabilitation Engineering and Technology, School of Health Science and Engineering University of Shanghai for Science and Technology  Shanghai China"},{"name":"Shanghai Engineering Research Center of Assistive Devices  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Zhou","sequence":"additional","affiliation":[{"name":"Institute of Rehabilitation Engineering and Technology, School of Health Science and Engineering University of Shanghai for Science and Technology  Shanghai China"},{"name":"Shanghai Engineering Research Center of Assistive Devices  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yunlong","family":"Liu","sequence":"additional","affiliation":[{"name":"Institute of Rehabilitation Engineering and Technology, School of Health Science and Engineering University of Shanghai for Science and Technology  Shanghai China"},{"name":"Shanghai Engineering Research Center of Assistive Devices  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongliu","family":"Yu","sequence":"additional","affiliation":[{"name":"Institute of Rehabilitation Engineering and Technology, School of Health Science and Engineering University of Shanghai for Science and Technology  Shanghai China"},{"name":"Shanghai Engineering Research Center of Assistive Devices  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2024,9,14]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00053-023-00684-7"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.3390\/s22176704"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10151-021-02544-2"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-020-02581-2"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1080\/003655202760230865"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10350-007-9009-2"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1136\/gut.50.4.480"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0040-1714285"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1089\/gyn.2023.0002"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10151-023-02778-2"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.12771\/emj.2022.e9"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.3389\/fped.2022.1077346"},{"key":"e_1_2_8_14_1","first-page":"13","article-title":"Prevalence of depression and its potential contributing factors in patients with enterostomy: a meta\u2010analytical review. Front","volume":"13","author":"Tang WSW","year":"2022","journal-title":"Psychiatry"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-015-1468-3"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-016-1572-z"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/aor.14434"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/aor.13645"},{"key":"e_1_2_8_19_1","doi-asserted-by":"crossref","unstructured":"HanD YanGZ WangZW JiangPP WangYB.A novel artificial puborectalis anal sphincter system based on transcutaneous energy transfer with rectal perception remodelling. Proceedings of 2019 14th IEEE international conference on electronic measurement & instruments (Icemi). 2019:1643\u20131649.","DOI":"10.1109\/ICEMI46757.2019.9101804"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1093\/ibd\/izx109"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-018-02149-1"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.5301\/ijao.5000312"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.2514\/1.J060791"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1088\/0964-1726\/25\/4\/045003"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/aor.14517"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1097\/MPG.0000000000003186"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.3233\/JAE-171065"},{"key":"e_1_2_8_28_1","doi-asserted-by":"crossref","unstructured":"ZanP DingQ YangBH LiTX ZhangYF IranK.Design of an actuator for artificial anal sphincter based on finite element analysis. 2020 12th international conference on advanced computational intelligence (Icaci). 2020:98\u2013101.","DOI":"10.1109\/ICACI49185.2020.9177706"}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/aor.14863","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/aor.14863","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/aor.14863","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,8]],"date-time":"2026-03-08T23:30:05Z","timestamp":1773012605000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/aor.14863"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,14]]},"references-count":27,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,1]]}},"alternative-id":["10.1111\/aor.14863"],"URL":"https:\/\/doi.org\/10.1111\/aor.14863","archive":["Portico"],"relation":{},"ISSN":["0160-564X","1525-1594"],"issn-type":[{"value":"0160-564X","type":"print"},{"value":"1525-1594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9,14]]},"assertion":[{"value":"2024-06-21","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-08-30","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-09-14","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}