{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T03:00:31Z","timestamp":1789959631580,"version":"4.0.1"},"reference-count":21,"publisher":"Wiley","license":[{"start":{"date-parts":[[2026,9,20]],"date-time":"2026-09-20T00:00:00Z","timestamp":1789862400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,9,20]],"date-time":"2026-09-20T00:00:00Z","timestamp":1789862400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Artificial Organs"],"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Impella support alters left ventricular pressure\u2010volume (PV) relations, but disease\u2010specific unloading responses across the full support range remain incompletely characterized. We developed a three\u2010dimensional pressure\u2010volume\u2010flow landscape (3D\u2010PVL) framework to quantify and compare ventricular unloading in acute myocardial infarction (AMI), dilated cardiomyopathy (DCM), and DCM with mitral regurgitation (DCM\u2009+\u2009MR).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>PV loops were simulated using a closed\u2010loop cardiovascular model at 51 Impella\u2010flow levels from 0 to 5.0\u2009L\/min. Loop\u2010centroid displacement and stroke work were normalized to their respective 0\u2010L\/min values, and their unscaled direction\u2010sensitive derivatives were combined into a composite response. The response index (RI) quantified integrated response magnitude, while interior peak\u2010response flow (Qpeak) identified the flow level of maximal incremental response among interior flow points. Pressure\u2010volume area (PVA) provided energetic validation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Unloading trajectories differed among disease states despite baseline normalization. Integrated response magnitudes were similar across the three disease models (RI: 1.33, 1.37, and 1.35 for AMI, DCM, and DCM\u2009+\u2009MR, respectively), whereas interior Qpeak differed at 3.40, 2.90, and 2.70\u2009L\/min. DCM\u2009+\u2009MR showed a renewed response increase at high flow, with its overall maximum occurring at the 5.0\u2010L\/min boundary. PVA\u2010based analysis preserved the higher\u2010flow response peak in AMI (3.60 vs. 3.10 and 2.90\u2009L\/min in DCM and DCM\u2009+\u2009MR).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The underlying disease substrate influenced the distribution of ventricular unloading across the Impella\u2010flow range despite similar integrated response magnitudes. The 3D\u2010PVL framework provides quantitative descriptors of disease\u2010specific unloading trajectories rather than clinically validated therapeutic targets.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/aor.70248","type":"journal-article","created":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T02:04:43Z","timestamp":1789956283000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Disease\u2010Specific Ventricular Unloading Responses to Impella Support Revealed by Three\u2010Dimensional Pressure\u2010Volume\u2010Flow Landscape Analysis"],"prefix":"10.1111","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5594-8072","authenticated-orcid":false,"given":"Hisato","family":"Takagi","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Surgery Shizuoka Medical Center  Shizuoka Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,9,20]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1253\/circj.CJ\u201023\u20100698"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2022.856870"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcha.2022.101007"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1177\/02676591241268389"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2013.05.049"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehz552"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.123.031401"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2018.12.084"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1093\/ehjqcco\/qcae109"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.3390\/biomedicines11030834"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/ejhf.2522"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/HCO.0000000000000770"},{"key":"e_1_2_10_14_1","first-page":"45","article-title":"CVSim: An Open\u2010Source Cardiovascular Simulator for Teaching and Research","volume":"3","author":"Heldt T.","year":"2010","journal-title":"Open Pacing, Electrophysiology & Therapy Journal"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2005.06.016"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.res.35.1.117"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.res.32.3.314"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.res.46.2.256"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1152\/ajpheart.01240.2005"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12265\u2010019\u201009876\u20103"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.118.038269"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.RES.53.3.306"}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/aor.70248","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/aor.70248","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/aor.70248","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T02:04:44Z","timestamp":1789956284000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/aor.70248"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,20]]},"references-count":21,"alternative-id":["10.1111\/aor.70248"],"URL":"https:\/\/doi.org\/10.1111\/aor.70248","archive":["Portico"],"relation":{},"ISSN":["0160-564X","1525-1594"],"issn-type":[{"value":"0160-564X","type":"print"},{"value":"1525-1594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,20]]},"assertion":[{"value":"2026-07-04","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-09-11","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-09-20","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"aor.70248"}}