{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,20]],"date-time":"2026-09-20T06:30:35Z","timestamp":1789885835208,"version":"4.0.1"},"reference-count":43,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2013,5,7]],"date-time":"2013-05-07T00:00:00Z","timestamp":1367884800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Acta Ophthalmologica"],"published-print":{"date-parts":[[2014,3]]},"abstract":"<jats:title>Abstract.<\/jats:title><jats:p><jats:bold>Purpose:\u2002<\/jats:bold> Fanconi anaemia (FA) is a multisystemic disorder with ocular implications. This study aims to describe visual function, ocular characteristics and visual processing skills in patients with FA after haematopoietic stem cell transplantation.<\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold> Ten patients with FA, ages 8\u201317\u2003years, underwent ophthalmological examinations, corneal, periocular and fundus photography, visual evoked potentials (VEPs), visual fields and ocular motor and visual processing information tests.<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold> Best\u2010corrected decimal visual acuity was \u22650.65 in all 20 eyes. Microcornea was present in 18 of 18 eyes, short axial lengths in six of six eyes, steep corneal curvatures in four of six eyes, ptosis in 14 of 16 eyes, short palpebral fissures in 15 of 16 eyes and hypotelorism in three of seven patients. Optic disc areas were smaller in patients with FA compared to controls (p\u2003=\u20030.0003 right, p\u2003=\u20030.0003 left eye). Visual fields were abnormal in 4 of 18 eyes, while VEP was abnormal in 1 of 20 eyes. Eight patients had ocular motor dysfunction, while nine of 10 patients showed delay in visual processing skills.<\/jats:p><jats:p><jats:bold>Conclusion:\u2002<\/jats:bold> Patients with FA can present with microcornea, microphthalmia, ptosis, steep corneal curvatures, small optic discs, ptosis and delay in visual processing skills. Detailed ophthalmological and visual processing skills assessments and developmental investigations are important to detect impairments and facilitate appropriate support.<\/jats:p>","DOI":"10.1111\/aos.12132","type":"journal-article","created":{"date-parts":[[2013,5,7]],"date-time":"2013-05-07T07:16:47Z","timestamp":1367911007000},"page":"171-178","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Ocular manifestations and visual functions in patients with Fanconi anaemia"],"prefix":"10.1111","volume":"92","author":[{"given":"Alba Lucia","family":"T\u00f6rnquist","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lene","family":"Martin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacek","family":"Winiarski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kristina Te\u00e4r","family":"Fahnehjelm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2013,5,7]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1002\/ajh.20232"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006982-200509000-00023"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2007.01146.x"},{"key":"e_1_2_6_5_1","volume-title":"BEERY VMI (the Beery \u2013 Buktenika developmental test of visual \u2013 motor integration)","author":"Beery KE","year":"2004"},{"key":"e_1_2_6_6_1","first-page":"73","volume-title":"Walsh & Hoyt\u2019s clincial neuroophthalmology","author":"Brodsky M","year":"2008"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1182\/blood-2004-07-2588"},{"key":"e_1_2_6_8_1","first-page":"E\u2010Abstract ARVO","article-title":"Axial length, anterior chamber depth, lens thickness and horizontal corneal diameter in normal children","volume":"46","author":"Costa A","year":"2005","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1053\/crad.2000.0445"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.04.036"},{"key":"e_1_2_6_11_1","first-page":"1","article-title":"Normal values for selected physical parameters: an aid to syndrome delineation","volume":"10","author":"Feingold M","year":"1974","journal-title":"Birth Defects Orig Artic Ser"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(02)00102-5"},{"key":"e_1_2_6_13_1","volume-title":"The reversal frequency test","author":"Gardner R","year":"1986"},{"key":"e_1_2_6_14_1","volume-title":"Test of visual\u2010perceptual skills (non\u2010motor) revised manual","author":"Gardner M","year":"1996"},{"key":"e_1_2_6_15_1","volume-title":"Test of visual\u2010perceptual skills (non\u2010motor) (upper level) revised manual","author":"Gardner M","year":"1997"},{"key":"e_1_2_6_16_1","first-page":"124","article-title":"A new visual\u2010verbal saccade test: the development eye movement test (DEM)","volume":"61","author":"Garzia RP","year":"1990","journal-title":"J Am Optom Assoc"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.91.6.1116"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1096-8628(19970110)68:1<58::AID-AJMG11>3.0.CO;2-N"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-0004.1995.tb03971.x"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1136\/jmg.19.6.412"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1985.01050060045020"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1007\/b97845"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.2005.00615.x"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/cncr.10627"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2008.01365.x"},{"key":"e_1_2_6_26_1","first-page":"42","article-title":"Useful age\u2010amplitude formula","volume":"38","author":"Hoffstedt H","year":"1950","journal-title":"Optom World"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1038\/sj.eye.6702960"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1080\/10245330512331390096"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.1971.tb05939.x"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1590\/S0004-27492011000300004"},{"key":"e_1_2_6_31_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.2005.00569.x"},{"key":"e_1_2_6_32_1","doi-asserted-by":"publisher","DOI":"10.1076\/opge.23.4.253.13880"},{"key":"e_1_2_6_33_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10633-009-9195-4"},{"key":"e_1_2_6_34_1","doi-asserted-by":"crossref","first-page":"337","DOI":"10.3928\/0191-3913-19991101-09","article-title":"Maldevelopment of neural crest cells in patients with typical uveal coloboma","volume":"36","author":"Ozeki H","year":"1999","journal-title":"J Pediatr Ophthalmol Strabismus"},{"key":"e_1_2_6_35_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2007.132746"},{"key":"e_1_2_6_36_1","doi-asserted-by":"publisher","DOI":"10.1002\/ajmg.1320280531"},{"key":"e_1_2_6_37_1","doi-asserted-by":"publisher","DOI":"10.1002\/1097-0177(2000)9999:9999<::AID-DVDY1030>3.0.CO;2-S"},{"key":"e_1_2_6_38_1","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.091402398"},{"key":"e_1_2_6_39_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2141.2004.05023.x"},{"key":"e_1_2_6_40_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2009.08.023"},{"key":"e_1_2_6_41_1","first-page":"61","article-title":"Accuracy of intraocular lens power calculations using the Zeiss IOL master. A prospective study","volume":"281","author":"Verhulst E","year":"2001","journal-title":"Bull Soc Belge Ophtalmol"},{"key":"e_1_2_6_42_1","doi-asserted-by":"publisher","DOI":"10.1038\/ng0693-202"},{"key":"e_1_2_6_43_1","doi-asserted-by":"publisher","DOI":"10.3129\/i06-078"},{"key":"e_1_2_6_44_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.75.9.538"}],"container-title":["Acta Ophthalmologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Faos.12132","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/aos.12132","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,24]],"date-time":"2023-09-24T10:16:58Z","timestamp":1695550618000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/aos.12132"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,5,7]]},"references-count":43,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2014,3]]}},"alternative-id":["10.1111\/aos.12132"],"URL":"https:\/\/doi.org\/10.1111\/aos.12132","archive":["Portico"],"relation":{},"ISSN":["1755-375X","1755-3768"],"issn-type":[{"value":"1755-375X","type":"print"},{"value":"1755-3768","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,5,7]]},"assertion":[{"value":"2013-05-07","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}