{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,20]],"date-time":"2026-06-20T14:01:20Z","timestamp":1781964080968,"version":"3.54.5"},"reference-count":14,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2013,12,26]],"date-time":"2013-12-26T00:00:00Z","timestamp":1388016000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Acta Ophthalmologica"],"published-print":{"date-parts":[[2014,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose<\/jats:title><jats:p>To present the outcomes of laser\u2010assisted <jats:italic>in situ<\/jats:italic> keratomileusis (<jats:styled-content style=\"fixed-case\">LASIK<\/jats:styled-content>) operations performed with the new three\u2010dimensional, transportable <jats:styled-content style=\"fixed-case\">FEMTO LDV<\/jats:styled-content> Z6 I femtosecond laser (Ziemer Ophthalmic Systems, Port, Switzerland) and the Allegretto Wave Concerto 500\u00a0Hz excimer laser (Wavelight <jats:styled-content style=\"fixed-case\">AG<\/jats:styled-content>, Erlangen, Germany) in terms of accuracy, reproducibility and safety of flap creation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This is a retrospective study of 309 consecutive eyes of 160 patients treated with the <jats:styled-content style=\"fixed-case\">FEMTO LDV<\/jats:styled-content> Z6 I for corneal flap creation. The target flap thickness was 90\u00a0<jats:italic>\u03bc<\/jats:italic>m. The size of the suction ring varied from 9.5 to 10.0\u00a0mm and target flap diameter from 9.3 to 9.6\u00a0mm, respectively. The target hinge length was 4.0\u00a0mm.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The <jats:styled-content style=\"fixed-case\">FEMTO LDV<\/jats:styled-content> Z6 I produced the 90\u2010<jats:italic>\u03bc<\/jats:italic>m targeted flaps very consistently (mean 90.1\u00a0\u00b1\u00a02.7\u00a0<jats:italic>\u03bc<\/jats:italic>m, range 78\u2013100). Mean flap diameter with the 9.3\u2010mm target flap diameter was 9.3\u00a0\u00b1\u00a00.1\u00a0mm (range 9.0\u20139.6) and with the 9.6\u2010mm target flap diameter 9.6\u00a0\u00b1\u00a00.1\u00a0mm (range 9.0\u20139.8). Mean hinge length was 3.9\u00a0\u00b1\u00a00.1\u00a0mm (range 3.3\u20134.2). Minor complications were reported in 15 (5%) eyes, but none of them prevented refractive laser treatment. The most common complications were bubbles in the conjunctiva (<jats:italic>n<\/jats:italic>\u00a0=\u00a07, 2%) and an opaque bubble layer inside the flap margin (<jats:italic>n<\/jats:italic>\u00a0=\u00a06, 2%). None of the eyes lost two Snellen lines of corrected distance visual acuity during 1\u2010month follow\u2010up.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>In the hands of an experienced surgeon, the transfer from the Classic <jats:styled-content style=\"fixed-case\">FEMTO LDV<\/jats:styled-content> to Z6 I was a safe and straight forward process yielding accurate and reproducible flaps.<\/jats:p><\/jats:sec>","DOI":"10.1111\/aos.12333","type":"journal-article","created":{"date-parts":[[2013,12,26]],"date-time":"2013-12-26T12:24:12Z","timestamp":1388060652000},"page":"650-655","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Laser\u2010assisted <i>in situ<\/i> keratomileusis flap creation with the three\u2010dimensional, transportable <scp>Z<\/scp>iemer <scp>FEMTO LDV<\/scp> model <scp>Z<\/scp>6 I femtosecond laser"],"prefix":"10.1111","volume":"92","author":[{"given":"Juhani","family":"Pietil\u00e4","sequence":"first","affiliation":[{"name":"Department of Ophthalmology Mehil\u00e4inen Hospital Tampere and Helsinki Finland"},{"name":"SILK Department of Ophthalmology School of Medicine University of Tampere Tampere Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anne","family":"Huhtala","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Mehil\u00e4inen Hospital Tampere and Helsinki Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Petri","family":"M\u00e4kinen","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Mehil\u00e4inen Hospital Tampere and Helsinki Finland"},{"name":"SILK Department of Ophthalmology School of Medicine University of Tampere Tampere Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kalle","family":"Salmenhaara","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Mehil\u00e4inen Hospital Tampere and Helsinki Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hannu","family":"Uusitalo","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Mehil\u00e4inen Hospital Tampere and Helsinki Finland"},{"name":"SILK Department of Ophthalmology School of Medicine University of Tampere Tampere Finland"},{"name":"TAUH Eye Center Tampere University Hospital Tampere Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2013,12,26]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.08.042"},{"key":"e_1_2_5_3_1","doi-asserted-by":"crossref","first-page":"12","DOI":"10.3928\/1081597X-20080101-03","article-title":"Very high\u2010frequency digital ultrasound measurement of the LASIK flap thickness profile using the IntraLase femtosecond laser and M2 and Carriazo\u2010Pendular microkeratomes","volume":"24","author":"Alio JL","year":"2008","journal-title":"J Refract Surg"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.04.044"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00578-9"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.02.043"},{"key":"e_1_2_5_7_1","first-page":"81","volume-title":"Flap creation in laser\u2010assisted in situ keratomileusis: From microkeratome to femtosecond lasers","author":"Pietil\u00e4 J","year":"2012"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20101215-02"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2012.02452.x"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-012-2110-9"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.1038\/eye.2013.244"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20081001-06"},{"key":"e_1_2_5_13_1","doi-asserted-by":"crossref","first-page":"556","DOI":"10.3928\/1081-597X-20060601-07","article-title":"Reproducibility of flap thickness with IntraLase FS and Moria LSK\u20101 and M2 microkeratomes","volume":"22","author":"Talamo JH","year":"2006","journal-title":"J Refract Surg"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2012.02406.x"},{"key":"e_1_2_5_15_1","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20120208-01"}],"container-title":["Acta Ophthalmologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Faos.12333","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Faos.12333","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/aos.12333","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T18:52:26Z","timestamp":1695495146000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/aos.12333"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,12,26]]},"references-count":14,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2014,11]]}},"alternative-id":["10.1111\/aos.12333"],"URL":"https:\/\/doi.org\/10.1111\/aos.12333","archive":["Portico"],"relation":{},"ISSN":["1755-375X","1755-3768"],"issn-type":[{"value":"1755-375X","type":"print"},{"value":"1755-3768","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,12,26]]},"assertion":[{"value":"2013-06-12","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2013-11-04","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2013-12-26","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}