{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T06:01:55Z","timestamp":1763704915503},"reference-count":21,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2014,1,30]],"date-time":"2014-01-30T00:00:00Z","timestamp":1391040000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Acta Ophthalmologica"],"published-print":{"date-parts":[[2014,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose<\/jats:title><jats:p>To compare the ocular wave\u2010front of eyes with silicone Intraocular lens (<jats:styled-content style=\"fixed-case\">IOL<\/jats:styled-content>s) with aspheric and spherical optics after cataract surgery, taking into account the patient's pupil size under reading conditions and after pupil dilatation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>In this institutional prospective, randomized, controlled, patient and examiner masked, bilateral trial with intra\u2010individual comparison, 60 eyes of 30 patients with bilateral age\u2010related cataract were included. Each patient received a spherical <jats:styled-content style=\"fixed-case\">IOL<\/jats:styled-content> (CeeOn Edge, 911A, <jats:styled-content style=\"fixed-case\">AMO<\/jats:styled-content>, Santa Ana, CA, USA) in one eye and an aspheric <jats:styled-content style=\"fixed-case\">IOL<\/jats:styled-content> (Tecnis, Z9000, <jats:styled-content style=\"fixed-case\">AMO<\/jats:styled-content>) in the contra\u2010lateral eye. Exclusion criteria were other ocular pathologies, capsular changes or zonular weakness. The main outcome variable was spherical aberration of the ocular wave\u2010front under mesopic pupil conditions measured 2\u00a0years after surgery. Additional outcome variables were visual acuity and photopic and mesopic contrast sensitivity.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>There was no significant difference in visual acuity between the two <jats:styled-content style=\"fixed-case\">IOL<\/jats:styled-content> types under physiological pupil conditions and also not after pupil dilation. However, spherical aberrations were significantly lower with the aspheric <jats:styled-content style=\"fixed-case\">IOL<\/jats:styled-content> (<jats:styled-content style=\"fixed-case\">SA<\/jats:styled-content>: spherical 0.38\u00a0<jats:italic>\u03bc<\/jats:italic>m, <jats:styled-content style=\"fixed-case\">SD<\/jats:styled-content>: 0.11\u00a0<jats:italic>\u03bc<\/jats:italic>m; aspheric 0.10\u00a0<jats:italic>\u03bc<\/jats:italic>m, <jats:styled-content style=\"fixed-case\">SD<\/jats:styled-content>: 0.13\u00a0<jats:italic>\u03bc<\/jats:italic>m; p\u00a0&lt;\u00a00.01), and there was a significant difference in contrast sensitivity at 12 cycles\/degree.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>This is the first randomized and masked trial on visual function and ocular wave\u2010front after implantation with this silicone aspheric <jats:styled-content style=\"fixed-case\">IOL<\/jats:styled-content>, taking the patients' own pupil size into account. The effect on visual function was detectable for mesopic contrast sensitivity, but there was no difference in visual acuity. The <jats:styled-content style=\"fixed-case\">SA<\/jats:styled-content> was found to be significantly lower under physiological pupil conditions as well as when recalculated for the rhexis size and under pharmacological dilatation.<\/jats:p><\/jats:sec>","DOI":"10.1111\/aos.12344","type":"journal-article","created":{"date-parts":[[2014,1,30]],"date-time":"2014-01-30T12:50:53Z","timestamp":1391086253000},"update-policy":"http:\/\/dx.doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Effect of an aspheric intraocular lens on the ocular wave\u2010front adjusted for pupil size and capsulorhexis size"],"prefix":"10.1111","volume":"92","author":[{"given":"Alja","family":"Crnej","sequence":"first","affiliation":[{"name":"Moorfields Eye Hospital NHS Foundation Trust London UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wolf","family":"Buehl","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Medical University of Vienna Vienna Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roman","family":"Greslechner","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Medical University of Vienna Vienna Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nino","family":"Hirnschall","sequence":"additional","affiliation":[{"name":"Moorfields Eye Hospital NHS Foundation Trust London UK"},{"name":"Department of Ophthalmology VIROS \u2013 Vienna Institute for Research in Ocular Surgery (VIROS) a Karl Landsteiner Institute Vienna Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oliver","family":"Findl","sequence":"additional","affiliation":[{"name":"Moorfields Eye Hospital NHS Foundation Trust London UK"},{"name":"Department of Ophthalmology VIROS \u2013 Vienna Institute for Research in Ocular Surgery (VIROS) a Karl Landsteiner Institute Vienna Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2014,1,30]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"crossref","first-page":"619","DOI":"10.3928\/1081597X-20080601-12","article-title":"Contrast sensitivity and higher order aberrations in eyes implanted with Acrysof IQ SN60WF and Acrysof SN60AT intraocular lenses","volume":"24","author":"Awwad ST","year":"2008","journal-title":"J Refract Surg"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.10.068"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.08.049"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.02-1042"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.04.028"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.10.035"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01509-2"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(97)00102-8"},{"key":"e_1_2_6_10_1","doi-asserted-by":"crossref","first-page":"1143","DOI":"10.1001\/archopht.120.9.1143","article-title":"Corneal optical aberrations and retinal image quality in patients in whom monofocal intraocular lenses were implanted","volume":"120","author":"Guirao A","year":"2002","journal-title":"Arch Ophthalmol"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.20.001155"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.11.018"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01983-1"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.09.017"},{"key":"e_1_2_6_15_1","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1016\/j.jcrs.2006.02.055","article-title":"Spherical aberration and contrast sensitivity after cataract surgery with the Tecnis Z9000 intraocular lens","volume":"32","author":"Mu\u00f1oz G","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2008.12.037"},{"key":"e_1_2_6_17_1","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1097\/00055735-200402000-00011","article-title":"Wave\u2010front technology in cataract surgery","volume":"15","author":"Packer M","year":"2004","journal-title":"Curr Opin Ophthalmol"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.06.031"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(00)00206-6"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.06-0444"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.08-2111"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.04.039"}],"container-title":["Acta Ophthalmologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Faos.12344","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Faos.12344","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/aos.12344","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T13:41:13Z","timestamp":1695476473000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/aos.12344"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,1,30]]},"references-count":21,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2014,8]]}},"alternative-id":["10.1111\/aos.12344"],"URL":"https:\/\/doi.org\/10.1111\/aos.12344","archive":["Portico"],"relation":{},"ISSN":["1755-375X","1755-3768"],"issn-type":[{"value":"1755-375X","type":"print"},{"value":"1755-3768","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,1,30]]},"assertion":[{"value":"2013-04-24","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2013-12-10","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2014-01-30","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}