{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T22:32:13Z","timestamp":1792794733593,"version":"4.5.0"},"reference-count":27,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2015,2,1]],"date-time":"2015-02-01T00:00:00Z","timestamp":1422748800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81271052"],"award-info":[{"award-number":["81271052"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Acta Ophthalmologica"],"published-print":{"date-parts":[[2016,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose<\/jats:title><jats:p>To evaluate the biomechanical properties of the cornea using Corneal Visualization Scheimpflug Technology (CorVis <jats:styled-content style=\"fixed-case\">ST<\/jats:styled-content>, Oculus) in eyes with primary open\u2010angle glaucoma (<jats:styled-content style=\"fixed-case\">POAG<\/jats:styled-content>) and normal control eyes.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>A comparative cross\u2010sectional study that included 42 patients with <jats:styled-content style=\"fixed-case\">POAG<\/jats:styled-content> and 60 normal control subjects matched for intraocular pressure (<jats:styled-content style=\"fixed-case\">IOP<\/jats:styled-content>) and central corneal thickness (<jats:styled-content style=\"fixed-case\">CCT<\/jats:styled-content>). <jats:styled-content style=\"fixed-case\">IOP<\/jats:styled-content> was measured with a Goldmann applanation tonometer (<jats:styled-content style=\"fixed-case\">GAT<\/jats:styled-content>). Corneal tomography and biomechanical parameters were measured with Pentacam (Oculus) and CorVis <jats:styled-content style=\"fixed-case\">ST<\/jats:styled-content>, respectively. Corneal biomechanical properties were compared between groups, and the associations between corneal biomechanical parameters and ocular characteristics were evaluated. Receiver operating characteristic (<jats:styled-content style=\"fixed-case\">ROC<\/jats:styled-content>) curves were used to establish a cut\u2010off value for the biomechanical parameters.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The following parameters of the CorVis <jats:styled-content style=\"fixed-case\">ST<\/jats:styled-content> showed a significant difference between eyes with <jats:styled-content style=\"fixed-case\">POAG<\/jats:styled-content> and normal eyes: first applanation velocity (V<jats:sub>in<\/jats:sub>), second applanation time (A\u2010time<jats:sub>2<\/jats:sub>), peak distance (<jats:styled-content style=\"fixed-case\">PD<\/jats:styled-content>) and deformation amplitude (<jats:styled-content style=\"fixed-case\">DA<\/jats:styled-content>). In the univariate analysis, <jats:styled-content style=\"fixed-case\">DA<\/jats:styled-content> was negatively correlated with <jats:styled-content style=\"fixed-case\">IOP<\/jats:styled-content> in both groups. For all biomechanical parameters, the areas under the <jats:styled-content style=\"fixed-case\">ROC<\/jats:styled-content> curve were &lt;0.80 and thus did not reach a good level of predictive accuracy for detecting <jats:styled-content style=\"fixed-case\">POAG<\/jats:styled-content>.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>CorVis <jats:styled-content style=\"fixed-case\">ST<\/jats:styled-content> offers an alternative method for measuring corneal biomechanical properties. Eyes with <jats:styled-content style=\"fixed-case\">POAG<\/jats:styled-content> exhibit a faster V<jats:sub>in<\/jats:sub>, longer A\u2010time<jats:sub>2<\/jats:sub>, lower <jats:styled-content style=\"fixed-case\">DA<\/jats:styled-content> and longer <jats:styled-content style=\"fixed-case\">PD<\/jats:styled-content> than do <jats:styled-content style=\"fixed-case\">IOP<\/jats:styled-content>\u2010 and <jats:styled-content style=\"fixed-case\">CCT<\/jats:styled-content>\u2010matched normal control eyes. The biomechanical parameters of the CorVis <jats:styled-content style=\"fixed-case\">ST<\/jats:styled-content> cannot readily be used for diagnosis of <jats:styled-content style=\"fixed-case\">POAG<\/jats:styled-content> in the individual patient.<\/jats:p><\/jats:sec>","DOI":"10.1111\/aos.12672","type":"journal-article","created":{"date-parts":[[2015,2,2]],"date-time":"2015-02-02T02:19:00Z","timestamp":1422843540000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":68,"title":["Corneal biomechanical characteristics measured by the CorVis Scheimpflug technology in eyes with primary open\u2010angle glaucoma and normal eyes"],"prefix":"10.1111","volume":"94","author":[{"given":"Lei","family":"Tian","sequence":"first","affiliation":[{"name":"Beijing Ophthalmology and Visual Sciences Key Laboratory Beijing Tongren Eye Center Beijing Tongren Hospital Capital Medical University Beijing China"},{"name":"Department of Ophthalmology Chinese PLA General Hospital Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dajiang","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Chinese PLA General Hospital Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ying","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Chinese PLA General Hospital Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoli","family":"Meng","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Chinese PLA General Hospital Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bing","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Chinese PLA General Hospital Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mei","family":"Ge","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Chinese PLA General Hospital Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yifei","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Chinese PLA General Hospital Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2015,2]]},"reference":[{"key":"e_1_2_5_2_1","unstructured":"Ambr\u00f3sioRJr CaldasD RamosI SantosR&BelinM(2011):Corneal Biomechanical Assessment Using Dynamic Ultra High\u2010Speed Scheimpflug Technology Non\u2010contact Tonometry (UHS\u2010ST NCT): Preliminary Results American Society of Cataract and Refractive Surgery\u2010American Society of Ophthalmic Administrators (ASCRS\u2010ASOA) Symposium and Congress. San Diego CA."},{"key":"e_1_2_5_3_1","first-page":"99","article-title":"Dynamic ultra high speed Scheimpflug imaging for assessing corneal biomechanical properties","volume":"72","author":"Ambr\u00f3sio R.","year":"2013","journal-title":"Braz J Ophthalmol"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.10-5580"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.1971.tb08231.x"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.122.4.477"},{"key":"e_1_2_5_7_1","first-page":"644","article-title":"Collagen fibrils in the human corneal stroma: structure and aging","volume":"39","author":"Daxer A","year":"1998","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.3.000473"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1080\/02713680601077145"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.exer.2008.02.006"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2012.02519.x"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0b013e318220daf0"},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2009.06.042"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e318279eb87"},{"key":"e_1_2_5_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(00)00658-9"},{"key":"e_1_2_5_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2007.08.004"},{"key":"e_1_2_5_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2007.03.016"},{"key":"e_1_2_5_18_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.12-11563"},{"key":"e_1_2_5_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.10.044"},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(89)32708-4"},{"key":"e_1_2_5_21_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e31821ffbd4"},{"key":"e_1_2_5_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2010.01.010"},{"key":"e_1_2_5_23_1","doi-asserted-by":"publisher","DOI":"10.1097\/00055735-199004000-00003"},{"key":"e_1_2_5_24_1","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1016\/j.ophtha.2010.12.001","article-title":"Determinants of corneal biomechanical properties in an adult Chinese population","volume":"118","author":"Narayanaswamy A","year":"2011","journal-title":"Ophthalmology"},{"key":"e_1_2_5_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/aos.12530"},{"key":"e_1_2_5_26_1","article-title":"Corneal deformation parameters provided by the Corvis\u2010ST Pachy\u2010Tonometer in healthy subjects and glaucoma patients","author":"Salvetat ML","year":"2014","journal-title":"J Glaucoma"},{"key":"e_1_2_5_27_1","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/147516"},{"key":"e_1_2_5_28_1","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20140521-01"}],"container-title":["Acta Ophthalmologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Faos.12672","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/aos.12672","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T12:59:13Z","timestamp":1695473953000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/aos.12672"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,2]]},"references-count":27,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2016,8]]}},"alternative-id":["10.1111\/aos.12672"],"URL":"https:\/\/doi.org\/10.1111\/aos.12672","archive":["Portico"],"relation":{},"ISSN":["1755-375X","1755-3768"],"issn-type":[{"value":"1755-375X","type":"print"},{"value":"1755-3768","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,2]]},"assertion":[{"value":"2014-08-22","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2015-01-01","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2015-02-01","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}