{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T19:54:06Z","timestamp":1784058846686,"version":"3.55.0"},"reference-count":23,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2019,2,7]],"date-time":"2019-02-07T00:00:00Z","timestamp":1549497600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Acta Ophthalmologica"],"published-print":{"date-parts":[[2019,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose<\/jats:title><jats:p>To evaluate the efficacy and safety of iris suture fixation of out\u2010of\u2010the\u2010bag dislocated three\u2010piece intraocular lenses (IOL).<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>In a retrospective interventional consecutive case series, a chart review was performed in two groups of patients: fourteen patients with a dislocated out\u2010of\u2010the\u2010bag three\u2010piece <jats:styled-content style=\"fixed-case\">IOL<\/jats:styled-content> that underwent <jats:styled-content style=\"fixed-case\">IOL<\/jats:styled-content> fixation to the iris using the Siepser sliding knot technique (Iris group) and 18 patients with in\u2010the\u2010bag dislocation that underwent <jats:styled-content style=\"fixed-case\">IOL<\/jats:styled-content> exchange with a new scleral\u2010sutured <jats:styled-content style=\"fixed-case\">IOL<\/jats:styled-content> (Exchange group). The Iris and Exchange groups were compared regarding surgical safety and efficacy. The median follow\u2010up time was 13.5\u00a0months [interquartile range (<jats:styled-content style=\"fixed-case\">IQR<\/jats:styled-content>), 10\u201320] in the Iris group and 12.5 (<jats:styled-content style=\"fixed-case\">IQR<\/jats:styled-content>, 10\u201314) in the Exchange group.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The best corrected visual acuity (BCVA) improved significantly in both groups (p\u00a0=\u00a00.005 and 0.00006, respectively). No difference in final <jats:styled-content style=\"fixed-case\">BCVA<\/jats:styled-content> was seen between the groups. Significantly less surgically induced astigmatism (p\u00a0=\u00a00.03) and a lower number of postoperative visits (p\u00a0=\u00a00.0006) was noted in the Iris group. Considering the type of surgery, there were few complications in the present material.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>In the study, suturing dislocated three\u2010piece <jats:styled-content style=\"fixed-case\">IOL<\/jats:styled-content>s to the iris appeared to be an acceptable surgical management with less surgically induced corneal astigmatism and fewer postoperative visits than <jats:styled-content style=\"fixed-case\">IOL<\/jats:styled-content> exchange. A larger study with a longer follow\u2010up time would be desirable to confirm the results.<\/jats:p><\/jats:sec>","DOI":"10.1111\/aos.14059","type":"journal-article","created":{"date-parts":[[2019,2,8]],"date-time":"2019-02-08T07:41:23Z","timestamp":1549611683000},"page":"583-588","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Iris suture fixation of out\u2010of\u2010the\u2010bag dislocated three\u2010piece intraocular lenses"],"prefix":"10.1111","volume":"97","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7601-3460","authenticated-orcid":false,"given":"Laura","family":"Armonaite","sequence":"first","affiliation":[{"name":"Department of Clinical Neuroscience Division of Ophthalmology and Vision St. Erik Eye Hospital Karolinska Institutet Stockholm Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"L\u00f6fgren","sequence":"additional","affiliation":[{"name":"Department of Clinical Neuroscience Division of Ophthalmology and Vision St. Erik Eye Hospital Karolinska Institutet Stockholm Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anders","family":"Behndig","sequence":"additional","affiliation":[{"name":"Department of Clinical Sciences\/Ophthalmology Ume\u00e5 University Hospital Ume\u00e5 Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2019,2,7]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.01.044"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.04.027"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2007.04.018"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.5301\/ejo.5000823"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2016.09.011"},{"key":"e_1_2_5_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.09.017"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1989.01070020501017"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.06.023"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2015.06.010"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)80019-4"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2016.10.024"},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-012-2057-x"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2009.08.022"},{"key":"e_1_2_5_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2008.01287.x"},{"key":"e_1_2_5_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2013.01.029"},{"key":"e_1_2_5_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-014-9964-2"},{"key":"e_1_2_5_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)81021-8"},{"key":"e_1_2_5_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.10.043"},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80612-8"},{"key":"e_1_2_5_21_1","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000006342"},{"key":"e_1_2_5_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.09.019"},{"key":"e_1_2_5_23_1","first-page":"1608","article-title":"Comparison of iris\u2010fixated foldable lens and scleral\u2010fixated foldable lens implantation in eyes with insufficient capsular support","volume":"9","author":"Zhang H","year":"2016","journal-title":"Int J Ophthalmol"},{"key":"e_1_2_5_24_1","first-page":"2562","article-title":"Out\u2010of\u2010the\u2010bag intraocular lens dislocation: outcomes of posterior chamber intraocular lens exchange, risk factors, and prevention","volume":"123","author":"Zheng DY","year":"2010","journal-title":"Chin Med J (Engl)"}],"container-title":["Acta Ophthalmologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Faos.14059","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/aos.14059","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/aos.14059","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/aos.14059","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,8]],"date-time":"2023-09-08T18:12:01Z","timestamp":1694196721000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/aos.14059"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,7]]},"references-count":23,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2019,9]]}},"alternative-id":["10.1111\/aos.14059"],"URL":"https:\/\/doi.org\/10.1111\/aos.14059","archive":["Portico"],"relation":{},"ISSN":["1755-375X","1755-3768"],"issn-type":[{"value":"1755-375X","type":"print"},{"value":"1755-3768","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,7]]},"assertion":[{"value":"2018-11-22","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-01-20","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-02-07","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}