{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T05:22:12Z","timestamp":1791436932231,"version":"4.3.3"},"reference-count":35,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2016,5,10]],"date-time":"2016-05-10T00:00:00Z","timestamp":1462838400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clinical Exper Ophthalmology"],"published-print":{"date-parts":[[2016,11]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>To evaluate the biometric factors associated with the accuracy of intraocular lens power predictions for cataract surgery in primary angle\u2010closure (PAC) or primary angle\u2010closure glaucoma (PACG) eyes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design<\/jats:title>\n                    <jats:p>Cross\u2010sectional study<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Participants<\/jats:title>\n                    <jats:p>This study included 103 PAC or PACG patients who had undergone cataract surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>All participants underwent anterior\u2010segment optical coherence tomography preoperatively. Two novel biometric factors \u2013 the relative lens vault (the ratio of lens vault to anterior vault) and the anterior vault (the sum of lens vault and anterior chamber depth) \u2013 were measured using customized software. The powers of the implanted intraocular lens and the actual postoperative refractive errors were compared. The mean refractive error and the median absolute error were calculated and compared using repeated measures ANOVA and Wilcoxon matched\u2010pairs signed\u2010rank test. The biometric factors associated with the postoperative refractive error were investigated by multivariate regression analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Main Outcome Measures<\/jats:title>\n                    <jats:p>Preoperative anterior\u2010segment biometric factors, difference between predicted and actual postoperative refraction.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The Haigis, Hoffer Q and SRK\/T formulas all showed a slight tendency toward resultant hyperopia, respectively (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u20090.001,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.05,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.003). The Hoffer Q formula had the least prediction error (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u20090.001). In the multivariate regression analysis, the relative lens vault was the only independent factor predicting postoperative refractive error (\n                      <jats:italic>\u03b2<\/jats:italic>\n                      \u2009=\u20090.392,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.011).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Intraocular lens power predictions for cataract surgery in PAC or PACG patients can be inaccurate. Such results might be associated with anterior\u2010segment biometric factors. Preoperative relative lens vault appears to be a significant factor predicting refractive outcome after cataract surgery in patients with PAC or PACG.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/ceo.12762","type":"journal-article","created":{"date-parts":[[2016,4,15]],"date-time":"2016-04-15T19:47:17Z","timestamp":1460749637000},"page":"693-700","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":25,"title":["Factors affecting refractive outcome after cataract surgery in primary angle\u2010closure glaucoma"],"prefix":"10.1111","volume":"44","author":[{"given":"Sam","family":"Seo","sequence":"first","affiliation":[{"name":"Department of Ophthalmology Cheil Eye Hospital  Daegu Korea"},{"name":"Department of Ophthalmology Seoul National University Hospital, Seoul National University College of Medicine  Seoul Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chong Eun","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Keimyung University Dongsan Medical Center  Daegu Korea"},{"name":"Department of Ophthalmology Seoul National University Hospital, Seoul National University College of Medicine  Seoul Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Young Kook","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Seoul National University Hospital, Seoul National University College of Medicine  Seoul Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sang Yoon","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Jeju National University Hospital  Jeju Korea"},{"name":"Department of Ophthalmology Seoul National University Hospital, Seoul National University College of Medicine  Seoul Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin Wook","family":"Jeoung","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Seoul National University Hospital, Seoul National University College of Medicine  Seoul Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ki Ho","family":"Park","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Seoul National University Hospital, Seoul National University College of Medicine  Seoul Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2016,5,10]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9394(53)90561-3"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.54.3.161"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.87.4.399"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.ijg.0000196619.34368.0a"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2005.11.018"},{"key":"e_1_2_5_7_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1442-9071.2000.00324.x"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2008.12.002"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.06.036"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2012.02805.x"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.05.073"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.06.037"},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.86.2.238"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80705-5"},{"key":"e_1_2_5_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80819-X"},{"key":"e_1_2_5_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2012.05.002"},{"key":"e_1_2_5_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-012-2013-9"},{"key":"e_1_2_5_18_1","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2415-14-93"},{"key":"e_1_2_5_19_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2004.043950"},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0146-2776(84)80044-0"},{"key":"e_1_2_5_21_1","doi-asserted-by":"publisher","DOI":"10.3341\/kjo.2011.25.6.375"},{"key":"e_1_2_5_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80338-0"},{"key":"e_1_2_5_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00376-X"},{"key":"e_1_2_5_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.07.032"},{"key":"e_1_2_5_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80676-1"},{"key":"e_1_2_5_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.08.054"},{"key":"e_1_2_5_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(98)91132-0"},{"key":"e_1_2_5_28_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.57.7.475"},{"key":"e_1_2_5_29_1","first-page":"12","article-title":"Ultrasonic evaluation of the lens thickness to axial length factor in primary closure angle glaucoma","volume":"9","author":"Qi Y","year":"1993","journal-title":"Yan Ke Xue Bao"},{"key":"e_1_2_5_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2005.10.006"},{"key":"e_1_2_5_31_1","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0b013e318064c803"},{"key":"e_1_2_5_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2014.02.006"},{"key":"e_1_2_5_33_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10384-013-0285-1"},{"key":"e_1_2_5_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2010.07.025"},{"key":"e_1_2_5_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2012.01.019"},{"key":"e_1_2_5_36_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-11630"}],"container-title":["Clinical &amp; Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fceo.12762","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fceo.12762","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ceo.12762","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,3]],"date-time":"2023-10-03T02:59:51Z","timestamp":1696301991000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/ceo.12762"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,5,10]]},"references-count":35,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2016,11]]}},"alternative-id":["10.1111\/ceo.12762"],"URL":"https:\/\/doi.org\/10.1111\/ceo.12762","archive":["Portico"],"relation":{},"ISSN":["1442-6404","1442-9071"],"issn-type":[{"value":"1442-6404","type":"print"},{"value":"1442-9071","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,5,10]]},"assertion":[{"value":"2015-12-18","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2016-04-08","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2016-05-10","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}