{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T05:21:31Z","timestamp":1791177691319,"version":"4.1.0"},"reference-count":71,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2021,7,29]],"date-time":"2021-07-29T00:00:00Z","timestamp":1627516800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clinical Exper Ophthalmology"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Cataract surgery for the subluxated crystalline lens is challenging. A thorough preoperative evaluation is important to determine the appropriate surgical approach for lens removal and the subsequent technique of intraocular lens placement. Important considerations include the extent and location of zonular weakness, and whether the zonular deficiency is caused by a static or progressive disease. The capsular bag should be preserved where possible. Creating a good\u2010sized and centred continuous curvilinear capsulorhexis is crucial to facilitate the use of capsular retractors and capsular tension devices, which provide capsular stability. Nucleus sculpting and rotation should be minimised to reduce zonular stress. Being cognisant of the possible intraoperative complications that may occur at each stage of the surgery and knowing how to reduce the risk of these complications occurring will enable surgeons to perform safe cataract surgery in these complex cases.<\/jats:p>","DOI":"10.1111\/ceo.13975","type":"journal-article","created":{"date-parts":[[2021,7,15]],"date-time":"2021-07-15T11:00:49Z","timestamp":1626346849000},"page":"1091-1101","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":36,"title":["Management of the subluxated crystalline lens: A review"],"prefix":"10.1111","volume":"49","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6308-5721","authenticated-orcid":false,"given":"Soon\u2010Phaik","family":"Chee","sequence":"first","affiliation":[{"name":"Singapore National Eye Centre  Singapore"},{"name":"Singapore Eye Research Institute  Singapore"},{"name":"Ophthalmology and Visual Sciences Duke\u2010National University of Singapore Graduate Medical School  Singapore"},{"name":"Department of Ophthalmology Yong Loo Lin School of Medicine, National University of Singapore  Singapore"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seng\u2010Ei","family":"Ti","sequence":"additional","affiliation":[{"name":"Singapore National Eye Centre  Singapore"},{"name":"Singapore Eye Research Institute  Singapore"},{"name":"Ophthalmology and Visual Sciences Duke\u2010National University of Singapore Graduate Medical School  Singapore"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicole Shu\u2010Wen","family":"Chan","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology National University Hospital  Singapore"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2021,7,29]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9394(73)91149-5"},{"key":"e_1_2_10_3_1","first-page":"42","article-title":"Homocystinuria \u2013 its ocular manifestations","volume":"3","author":"Spaeth GL","year":"1966","journal-title":"J Pediatr Ophthalmol"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9394(74)90685-0"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/0039-6257(82)90069-8"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1967.00980030291006"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1038\/eye.1998.271"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1995.01100090017008"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1988.01060140184009"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1080\/02713683.2018.1548130"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0b013e318241b85b"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaapos.2006.01.218"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.09.005"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2019.08.001"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-016-3297-y"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.01.026"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.01.030"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.02.035"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.10.070"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.4103\/0301-4738.103801"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1038\/eye.2017.160"},{"key":"e_1_2_10_22_1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1159\/000507120","article-title":"Use of techniques for scleral and iris fixation in secondary implantation of intraocular lenses","volume":"64","author":"Castaldelli GB","year":"2021","journal-title":"Ophthalmic Res"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.05.010"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.05.029"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.06.031"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.advms.2018.08.005"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.12.060"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.08.008"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2015-306839"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2018-311868"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2020.03.021"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.07.013"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2014-306579"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_960_16"},{"key":"e_1_2_10_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2017.03.036"},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(87)80131-1"},{"key":"e_1_2_10_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00344-4"},{"key":"e_1_2_10_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.10.017"},{"key":"e_1_2_10_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2016.09.021"},{"key":"e_1_2_10_40_1","first-page":"507","article-title":"Capsular tension rings: update on endocapsular support devices","volume":"19","author":"Hasanee K","year":"2006","journal-title":"Ophthalmol Clin North Am"},{"key":"e_1_2_10_41_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2019.08.046"},{"key":"e_1_2_10_42_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.02.048"},{"key":"e_1_2_10_43_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2010.10.035"},{"key":"e_1_2_10_44_1","first-page":"3733","article-title":"Capsular tension ring implantation after lens extraction for management of subluxated cataracts","volume":"7","author":"Ma X","year":"2014","journal-title":"Int J Clin Exp Pathol"},{"key":"e_1_2_10_45_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(98)80218-6"},{"key":"e_1_2_10_46_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2016.04.002"},{"key":"e_1_2_10_47_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.06.015"},{"key":"e_1_2_10_48_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.10.009"},{"key":"e_1_2_10_49_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.03.016"},{"key":"e_1_2_10_50_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2003.12.002"},{"key":"e_1_2_10_51_1","doi-asserted-by":"publisher","DOI":"10.1590\/S0004-27492006000100021"},{"key":"e_1_2_10_52_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2016.10.012"},{"key":"e_1_2_10_53_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.03.011"},{"key":"e_1_2_10_54_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mehy.2020.110402"},{"key":"e_1_2_10_55_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.03.038"},{"key":"e_1_2_10_56_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.09.029"},{"key":"e_1_2_10_57_1","doi-asserted-by":"publisher","DOI":"10.3928\/0191-3913-19991101-05"},{"key":"e_1_2_10_58_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaapos.2007.03.012"},{"key":"e_1_2_10_59_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.05.001"},{"key":"e_1_2_10_60_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.08.032"},{"key":"e_1_2_10_61_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2013.07.057"},{"key":"e_1_2_10_62_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.01.014"},{"key":"e_1_2_10_63_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2017.09.003"},{"key":"e_1_2_10_64_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.05.027"},{"key":"e_1_2_10_65_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.01.003"},{"key":"e_1_2_10_66_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.04.036"},{"key":"e_1_2_10_67_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2011.11.012"},{"key":"e_1_2_10_68_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2011.02612.x"},{"key":"e_1_2_10_69_1","doi-asserted-by":"publisher","DOI":"10.5301\/ejo.5000366"},{"key":"e_1_2_10_70_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2007.06.009"},{"key":"e_1_2_10_71_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcjo.2017.07.015"},{"key":"e_1_2_10_72_1","doi-asserted-by":"publisher","DOI":"10.1097\/IAE.0000000000002268"}],"container-title":["Clinical &amp; Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ceo.13975","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/ceo.13975","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ceo.13975","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T07:23:38Z","timestamp":1693207418000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/ceo.13975"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,29]]},"references-count":71,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["10.1111\/ceo.13975"],"URL":"https:\/\/doi.org\/10.1111\/ceo.13975","archive":["Portico"],"relation":{},"ISSN":["1442-6404","1442-9071"],"issn-type":[{"value":"1442-6404","type":"print"},{"value":"1442-9071","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,7,29]]},"assertion":[{"value":"2021-06-29","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-07-13","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-07-29","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}