{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T23:05:21Z","timestamp":1790723121234,"version":"4.1.0"},"reference-count":142,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2022,6,27]],"date-time":"2022-06-27T00:00:00Z","timestamp":1656288000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100011697","name":"R\u00e9gion Bretagne","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100011697","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clinical Exper Ophthalmology"],"published-print":{"date-parts":[[2022,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Dry eye disease (DED) is a common eye condition worldwide and a primary reason for visits to the ophthalmologist. DED diagnosis is performed through a combination of tests, some of which are unfortunately invasive, non\u2010reproducible and lack accuracy. The following review describes methods that diagnose and measure the extent of eye dryness, enabling clinicians to quantify its severity. Our aim with this paper is to review classical methods as well as those that incorporate automation. For only four ways of quantifying DED, we take a deeper look into what main elements can benefit from automation and the different ways studies have incorporated it. Like numerous medical fields, Artificial Intelligence (AI) appears to be the path towards quality DED diagnosis. This review categorises diagnostic methods into the following: classical, semi\u2010automated and promising AI\u2010based automated methods.<\/jats:p>","DOI":"10.1111\/ceo.14119","type":"journal-article","created":{"date-parts":[[2022,6,3]],"date-time":"2022-06-03T06:33:42Z","timestamp":1654238022000},"page":"653-666","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Automation of dry eye disease quantitative assessment: A review"],"prefix":"10.1111","volume":"50","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6394-7179","authenticated-orcid":false,"given":"Ikram","family":"Brahim","sequence":"first","affiliation":[{"name":"Inserm, UMR 1101  Brest France"},{"name":"Inserm, UMR 1227  Brest France"},{"name":"Universit\u00e9 Bretagne Occidentale  Brest France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6309-6156","authenticated-orcid":false,"given":"Mathieu","family":"Lamard","sequence":"additional","affiliation":[{"name":"Inserm, UMR 1101  Brest France"},{"name":"Universit\u00e9 Bretagne Occidentale  Brest France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6829-9086","authenticated-orcid":false,"given":"Anas\u2010Alexis","family":"Benyoussef","sequence":"additional","affiliation":[{"name":"Service d'Ophtalmologie CHRU Brest  Brest France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1669-7140","authenticated-orcid":false,"given":"Gwenol\u00e9","family":"Quellec","sequence":"additional","affiliation":[{"name":"Inserm, UMR 1101  Brest France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2022,6,27]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.07-0337"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1542-0124(12)70081-2"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-13125"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2016.17216"},{"issue":"7","key":"e_1_2_10_6_1","first-page":"1647","article-title":"Using artificial intelligence to detect glaucoma and age related macula degeneration","volume":"61","author":"Lay B","year":"2020","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2017.04.012"},{"key":"e_1_2_10_8_1","first-page":"bjophthalmol\u201020","article-title":"Artificial intelligence and deep learning in ophthalmology","volume":"103","author":"Ting D","year":"2018","journal-title":"Br J Ophthalmol"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.preteyeres.2019.04.003"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtos.2017.08.003"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1542-0124(12)70139-8"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.exer.2013.07.027"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1136\/annrheumdis\u20102018\u2010eular.4455"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtos.2019.01.004"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1080\/17434440.2018.1435271"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S45444"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S1496"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12177-008-9006-2"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e318181ae36"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.exer.2013.08.010"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1969.00990020012003"},{"issue":"3","key":"e_1_2_10_22_1","first-page":"264","article-title":"Promising artificial intelligence\u2010machine learning\u2010deep learning algorithms in ophthalmology","volume":"8","author":"Balyen L","year":"2019","journal-title":"Asia\u2010Pac J Ophthalmol"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/s40123-018-0153-7"},{"key":"e_1_2_10_24_1","first-page":"53","article-title":"Deep learning in ophthalmology: a review","volume":"1","author":"Grewal P","year":"2018","journal-title":"Can J Ophthalmol"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2018.01.023"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0000000000000470"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2017.10.031"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.artmed.2019.101758"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.3390\/ijms20246132"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF01946264"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199302000-00011"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1983.01040020385009"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1097\/00004397-197301310-00015"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9394(61)91827-X"},{"key":"e_1_2_10_35_1","doi-asserted-by":"publisher","DOI":"10.1001\/archotol.1975.00780340025005"},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.1985.tb01583.x"},{"key":"e_1_2_10_37_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-198503000-00006"},{"key":"e_1_2_10_38_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.1982.tb05783.x"},{"key":"e_1_2_10_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9394(79)90678-0"},{"key":"e_1_2_10_40_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1962.00960020564008"},{"key":"e_1_2_10_41_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003226-199801000-00007"},{"key":"e_1_2_10_42_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.82.6.666"},{"key":"e_1_2_10_43_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.05-0802"},{"key":"e_1_2_10_44_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1995.01100010086025"},{"key":"e_1_2_10_45_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1367-0484(98)80035-0"},{"key":"e_1_2_10_46_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2007.04.006"},{"key":"e_1_2_10_47_1","doi-asserted-by":"publisher","DOI":"10.1177\/112067211002000502"},{"key":"e_1_2_10_48_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000192352.78935.e0"},{"key":"e_1_2_10_49_1","doi-asserted-by":"publisher","DOI":"10.3928\/1542-8877-20060301-06"},{"issue":"5","key":"e_1_2_10_50_1","first-page":"NC01","article-title":"Anterior segment optical coherence tomography for tear meniscus evaluation and its correlation with other tear variables in healthy individuals","volume":"10","author":"Raj A","year":"2016","journal-title":"J Clin Diagn Res"},{"key":"e_1_2_10_51_1","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000000575"},{"key":"e_1_2_10_52_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2014-306453"},{"key":"e_1_2_10_53_1","doi-asserted-by":"publisher","DOI":"10.1111\/aos.13559"},{"key":"e_1_2_10_54_1","doi-asserted-by":"publisher","DOI":"10.1109\/ISBI.2010.5490143"},{"key":"e_1_2_10_55_1","doi-asserted-by":"publisher","DOI":"10.1109\/IECBES.2012.6498078"},{"key":"e_1_2_10_56_1","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.10.002744"},{"key":"e_1_2_10_57_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.14-15318"},{"key":"e_1_2_10_58_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1950.02920180008004"},{"key":"e_1_2_10_59_1","first-page":"69","article-title":"Zur Ernahrung der Cornea","volume":"20","author":"Pfluger","year":"1882","journal-title":"Klin Monatsbl Augenheilkd"},{"key":"e_1_2_10_60_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.preteyeres.2014.10.001"},{"key":"e_1_2_10_61_1","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S178113"},{"issue":"13","key":"e_1_2_10_62_1","first-page":"2809","article-title":"An image\u2010based method for quantitative determination of corneal staining in dry eye patients","volume":"49","author":"Ornberg RL","year":"2008","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_10_63_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.17-21831"},{"key":"e_1_2_10_64_1","doi-asserted-by":"publisher","DOI":"10.1001\/jamaophthalmol.2017.3346"},{"key":"e_1_2_10_65_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.14-15618"},{"key":"e_1_2_10_66_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10916-018-1086-3"},{"key":"e_1_2_10_67_1","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.8.6.34"},{"key":"e_1_2_10_68_1","doi-asserted-by":"publisher","DOI":"10.1109\/JSEN.2019.2948576"},{"key":"e_1_2_10_69_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.1969.tb03711.x"},{"key":"e_1_2_10_70_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1977.04450030087010"},{"key":"e_1_2_10_71_1","doi-asserted-by":"publisher","DOI":"10.1038\/eye.2000.156"},{"key":"e_1_2_10_72_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-94568-9"},{"key":"e_1_2_10_73_1","doi-asserted-by":"publisher","DOI":"10.1038\/eye.1995.149"},{"key":"e_1_2_10_74_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.80.1.29"},{"key":"e_1_2_10_75_1","doi-asserted-by":"publisher","DOI":"10.3109\/02713688508999960"},{"key":"e_1_2_10_76_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.1989.tb00833.x"},{"key":"e_1_2_10_77_1","doi-asserted-by":"publisher","DOI":"10.1016\/0141-7037(93)80022-6"},{"key":"e_1_2_10_78_1","doi-asserted-by":"publisher","DOI":"10.1111\/cxo.12546"},{"key":"e_1_2_10_79_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.83.7.774"},{"key":"e_1_2_10_80_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(02)02221-3"},{"key":"e_1_2_10_81_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.ico.0000136667.63870.51"},{"key":"e_1_2_10_82_1","first-page":"395","volume-title":"Contact Lens Complications E\u2010Book","author":"Efron N","year":"2018"},{"key":"e_1_2_10_83_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(93)31704-5"},{"key":"e_1_2_10_84_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.03-0712"},{"key":"e_1_2_10_85_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000195569.36185.fd"},{"key":"e_1_2_10_86_1","doi-asserted-by":"publisher","DOI":"10.1117\/12.678421"},{"key":"e_1_2_10_87_1","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e31816f630e"},{"key":"e_1_2_10_88_1","doi-asserted-by":"publisher","DOI":"10.1117\/1.3598837"},{"key":"e_1_2_10_89_1","doi-asserted-by":"publisher","DOI":"10.1109\/CBMS.2014.54"},{"issue":"1","key":"e_1_2_10_90_1","first-page":"1","article-title":"Comparison of invasive & non\u2010invasive tear break up time measurement techniques in contact lens users","volume":"19","author":"Khan HA","year":"2018","journal-title":"Trends Ophthalmol Open Access J"},{"issue":"1","key":"e_1_2_10_91_1","first-page":"63","article-title":"Noninvasive tear film break\u2010up time assessment using handheld lipid layer examination instrument","volume":"58","author":"Vidas Pauk S","year":"2019","journal-title":"Acta Clin Croat"},{"key":"e_1_2_10_92_1","doi-asserted-by":"publisher","DOI":"10.1007\/978\u20103\u2010540\u201075757\u20103_96"},{"key":"e_1_2_10_93_1","doi-asserted-by":"publisher","DOI":"10.1109\/DICTA.2008.70"},{"key":"e_1_2_10_94_1","doi-asserted-by":"publisher","DOI":"10.1145\/2093698.2093821"},{"key":"e_1_2_10_95_1","doi-asserted-by":"publisher","DOI":"10.1117\/1.3562964"},{"key":"e_1_2_10_96_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00138-008-0155-x"},{"key":"e_1_2_10_97_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-21498-1_9"},{"key":"e_1_2_10_98_1","doi-asserted-by":"publisher","DOI":"10.1109\/ICTAI.2012.56"},{"key":"e_1_2_10_99_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10044-014-0402-x"},{"key":"e_1_2_10_100_1","first-page":"33","article-title":"Analysis of a Random Forests Model","volume":"13","author":"Biau G","year":"2012","journal-title":"J Mach Learn Res"},{"key":"e_1_2_10_101_1","doi-asserted-by":"publisher","DOI":"10.1023\/A:1010933404324"},{"key":"e_1_2_10_102_1","doi-asserted-by":"publisher","DOI":"10.1023\/A:1009715923555"},{"key":"e_1_2_10_103_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.infrared.2015.04.007"},{"key":"e_1_2_10_104_1","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1007\/978-3-662-44440-5_11","volume-title":"Agents and Artificial Intelligence","author":"M\u00e9ndez R","year":"2014"},{"key":"e_1_2_10_105_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11517-016-1534-5"},{"key":"e_1_2_10_106_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2013.04.007"},{"key":"e_1_2_10_107_1","doi-asserted-by":"publisher","DOI":"10.1109\/JSEN.2018.2850940"},{"key":"e_1_2_10_108_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.10-6997a"},{"issue":"244","key":"e_1_2_10_109_1","first-page":"s224","article-title":"Pathological alterations in Meibomian gland dysfunction as an important factor in ocular surface disease","volume":"87","author":"Barabino S","year":"2009","journal-title":"Acta Ophthalmol"},{"issue":"4","key":"e_1_2_10_110_1","first-page":"522","article-title":"Meibomian gland studies: comparison of steer and human lipids","volume":"20","author":"Nicolaides N","year":"1981","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_10_111_1","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2019.00291"},{"key":"e_1_2_10_112_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.1995.9500071k.x"},{"key":"e_1_2_10_113_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.1990.tb00968.x"},{"key":"e_1_2_10_114_1","doi-asserted-by":"publisher","DOI":"10.1007\/s40135-014-0041-9"},{"key":"e_1_2_10_115_1","doi-asserted-by":"publisher","DOI":"10.1038\/eye.1991.65"},{"key":"e_1_2_10_116_1","first-page":"169","article-title":"Development of definitive and reliable grading scales for meibomian gland dysfunction","volume":"1","author":"Arita R","year":"2016","journal-title":"Am J Ophthalmol"},{"key":"e_1_2_10_117_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2007.06.031"},{"issue":"210","key":"e_1_2_10_118_1","first-page":"637","article-title":"Biomicroscopic study of the glands of meibomius","volume":"210","author":"Tapie R","year":"1977","journal-title":"Ann Ocul"},{"key":"e_1_2_10_119_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(85)33848-4"},{"issue":"14","key":"e_1_2_10_120_1","first-page":"588","article-title":"An Assement of subjective and objective grading of meibography images","volume":"53","author":"Pult H","year":"2012","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_10_121_1","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.9.9.34"},{"key":"e_1_2_10_122_1","doi-asserted-by":"publisher","DOI":"10.1109\/ISSPIT47144.2019.9001823"},{"key":"e_1_2_10_123_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jfo.2015.07.015"},{"key":"e_1_2_10_124_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-018-0307-9"},{"key":"e_1_2_10_125_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.18-25571"},{"key":"e_1_2_10_126_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.18-24497"},{"key":"e_1_2_10_127_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1463-5224.2008.00660.x"},{"key":"e_1_2_10_128_1","doi-asserted-by":"publisher","DOI":"10.3109\/02713689308999470"},{"key":"e_1_2_10_129_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.117.6.723"},{"key":"e_1_2_10_130_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0165558"},{"issue":"38","key":"e_1_2_10_131_1","first-page":"1","article-title":"Novel application software for the semi\u2010automated analysis of infrared meibography images","volume":"1","author":"Shehzad D","year":"2019","journal-title":"Cornea"},{"key":"e_1_2_10_132_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-020-05034-7"},{"key":"e_1_2_10_133_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtos.2020.09.001"},{"key":"e_1_2_10_134_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.optom.2013.09.001"},{"key":"e_1_2_10_135_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2012-303014"},{"key":"e_1_2_10_136_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12938-017-0426-8"},{"key":"e_1_2_10_137_1","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.8.6.37"},{"key":"e_1_2_10_138_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bspc.2019.101776"},{"key":"e_1_2_10_139_1","doi-asserted-by":"publisher","DOI":"10.21037\/qims-20-611"},{"key":"e_1_2_10_140_1","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000002279"},{"issue":"7","key":"e_1_2_10_141_1","first-page":"2634","article-title":"Meibomian gland morphology and ghost prediction with deep learning","volume":"61","author":"Wang J","year":"2020","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_10_142_1","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2021.3056234"},{"key":"e_1_2_10_143_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmjophth-2020-000436"}],"container-title":["Clinical &amp; Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ceo.14119","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/ceo.14119","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ceo.14119","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,23]],"date-time":"2023-08-23T10:40:53Z","timestamp":1692787253000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/ceo.14119"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,27]]},"references-count":142,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2022,8]]}},"alternative-id":["10.1111\/ceo.14119"],"URL":"https:\/\/doi.org\/10.1111\/ceo.14119","archive":["Portico"],"relation":{},"ISSN":["1442-6404","1442-9071"],"issn-type":[{"value":"1442-6404","type":"print"},{"value":"1442-9071","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,27]]},"assertion":[{"value":"2021-11-16","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-05-14","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-06-27","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}