{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T14:06:02Z","timestamp":1777989962681,"version":"3.51.4"},"reference-count":23,"publisher":"Computers, Materials and Continua (Tech Science Press)","issue":"6","license":[{"start":{"date-parts":[[2015,9,1]],"date-time":"2015-09-01T00:00:00Z","timestamp":1441065600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Congenital Heart Disease"],"published-print":{"date-parts":[[2016,12]]},"DOI":"10.1111\/chd.12356","type":"journal-article","created":{"date-parts":[[2016,4,15]],"date-time":"2016-04-15T03:48:49Z","timestamp":1460692129000},"page":"637-646","source":"Crossref","is-referenced-by-count":28,"title":["Radiation Protocol for Three-Dimensional Rotational Angiography to Limit Procedural Radiation Exposure in the Pediatric Cardiac Catheterization Lab"],"prefix":"10.32604","volume":"11","author":[{"given":"Lauren","family":"Haddad","sequence":"first","affiliation":[{"name":"Pediatric Cardiology Associates; Baton Rouge La USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B. Rush","family":"Waller","sequence":"additional","affiliation":[{"name":"Department of Pediatrics; Division of Pediatric Cardiology; Memphis Tenn USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jason","family":"Johnson","sequence":"additional","affiliation":[{"name":"Department of Pediatrics; Division of Pediatric Cardiology; Memphis Tenn USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Asim","family":"Choudhri","sequence":"additional","affiliation":[{"name":"Department of Radiology; University of Tennessee Health Science Center, Le Bonheur Children's Hospital; Memphis Tenn USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vera","family":"McGhee","sequence":"additional","affiliation":[{"name":"College of Medicine; University of Tennessee Health Science Center; Memphis Tenn USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Zurakowski","sequence":"additional","affiliation":[{"name":"Department of Biostatistics; Harvard Medical School, Associate Professor of Anesthesia and Biostatistics, Boston Children's Hospital; Boston Mass USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew","family":"Kuhls-Gilcrist","sequence":"additional","affiliation":[{"name":"Toshiba America Medical Systems, Toshiba Education Center; Irvine Calif USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shyam","family":"Sathanandam","sequence":"additional","affiliation":[{"name":"Department of Pediatrics; Division of Pediatric Cardiology; Memphis Tenn USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"17807","published-online":{"date-parts":[[2016,4,14]]},"reference":[{"key":"10.1111\/chd.12356-BIB0001|chd12356-cit-0001","first-page":"571","article-title":"Three-dimensional digital angiography: new tool for simultaneous three-dimensional rendering of vascular and osseous information during rotational angiography","volume":"25","author":"Gailloud","year":"2004","journal-title":"Am J Neuroradiol."},{"key":"10.1111\/chd.12356-BIB0002|chd12356-cit-0002","first-page":"686","article-title":"Clinical benefits of rotational 3D angiography in endovascular treatment of ruptured cerebral aneurysm","volume":"23","author":"Abe","year":"2002","journal-title":"Am J Neuroradiol."},{"key":"10.1111\/chd.12356-BIB0003|chd12356-cit-0003","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1016\/j.jvir.2007.07.006","article-title":"Effect of C-arm angiographic CT on transcatheter arterial chemoembolization of liver tumors","volume":"18","author":"Virmani","year":"2007","journal-title":"J Vasc Interv Radiol."},{"key":"10.1111\/chd.12356-BIB0004|chd12356-cit-0004","doi-asserted-by":"crossref","first-page":"1627","DOI":"10.1007\/s10554-011-9993-0","article-title":"Assessment of three dimensional quantitative coronary analysis by using rotational angiography for measurement of vessel length and diameter","volume":"28","author":"Lee","year":"2012","journal-title":"Int J Cardiovasc Imaging."},{"key":"10.1111\/chd.12356-BIB0005|chd12356-cit-0005","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/s10840-009-9397-4","article-title":"Rapid ventricular pacing to optimize rotational angiography in atrial fibrillation ablation","volume":"26","author":"Gerds-Li","year":"2011","journal-title":"J Interv Card Electrophysiol."},{"key":"10.1111\/chd.12356-BIB0006|chd12356-cit-0006","first-page":"1","article-title":"The emerging use of 3-dimensional rotational angiography in congenital heart disease","volume":"9","author":"Zahn","year":"2011","journal-title":"Congenital Cardiol Today"},{"key":"10.1111\/chd.12356-BIB0007|chd12356-cit-0007","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.1016\/j.jcmg.2010.09.011","article-title":"Use of angiographic CT imaging in the cardiac catheterization laboratory for congenital heart disease","volume":"3","author":"Glatz","year":"2010","journal-title":"JACC Cardiovasc Imaging."},{"key":"10.1111\/chd.12356-BIB0008|chd12356-cit-0008","doi-asserted-by":"crossref","first-page":"1718","DOI":"10.1093\/europace\/eut140","article-title":"Cardiac three-dimensional rotational angiography can be performed with low radiation dose while preserving image quality","volume":"15","author":"Buck","year":"2013","journal-title":"Europace."},{"key":"10.1111\/chd.12356-BIB0009|chd12356-cit-0009","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1093\/europace\/eup394","article-title":"Three-dimensional cardiac rotational angiography: effective radiation dose and image quality implications","volume":"12","author":"Wielandts","year":"2010","journal-title":"Europace."},{"key":"10.1111\/chd.12356-BIB0010|chd12356-cit-0010","doi-asserted-by":"crossref","first-page":"625","DOI":"10.3109\/02841851003698206","article-title":"Automatic exposure control in computed tomography-an evaluation of systems from different manufacturers","volume":"51","author":"S\u00f6derberg","year":"2010","journal-title":"Acta Radiol."},{"key":"10.1111\/chd.12356-BIB0011|chd12356-cit-0011","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/s10840-009-9397-4","article-title":"Rapid ventricular pacing to optimize rotational angiography in atrial fibrillation ablation","volume":"26","author":"Gerds-Li","year":"2009","journal-title":"J Interv Card Electrophysiol."},{"key":"10.1111\/chd.12356-BIB0012|chd12356-cit-0012","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1016\/j.jpeds.2013.10.074","article-title":"Cumulative exposure to medical radiation for children requiring surgery for congenital heart disease","volume":"164","author":"Glatz","year":"2014","journal-title":"J Pediatr."},{"key":"10.1111\/chd.12356-BIB0013|chd12356-cit-0013","first-page":"1","article-title":"Recommendations of the International Commission on Radiologic Protection","volume":"26","author":"Lindell","year":"1991","journal-title":"Ann ICRP."},{"key":"10.1111\/chd.12356-BIB0014|chd12356-cit-0014","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1161\/01.CIR.0000151098.52656.3A","article-title":"Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization","volume":"111","author":"Bacher","year":"2005","journal-title":"Circulation."},{"key":"10.1111\/chd.12356-BIB0015|chd12356-cit-0015","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1007\/s00246-011-0064-z","article-title":"Radiation exposure in children during the current era of pediatric cardiac intervention","volume":"33","author":"El Sayed","year":"2012","journal-title":"Pediatr Cardiol."},{"key":"10.1111\/chd.12356-BIB0016|chd12356-cit-0016","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1259\/bjr\/19929794","article-title":"Diagnostic reference levels and effective dose in paediatric cardiac catheterization","volume":"80","author":"Onnasch","year":"2007","journal-title":"Br J Radiol."},{"key":"10.1111\/chd.12356-BIB0017|chd12356-cit-0017","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1007\/s00247-006-0194-2","article-title":"The ALARA concept in pediatric cardiac catheterization: techniques and tactics for managing radiation dose","volume":"36","author":"Justino","year":"2006","journal-title":"Pediatr Radiol."},{"key":"10.1111\/chd.12356-BIB0018|chd12356-cit-0018","doi-asserted-by":"crossref","first-page":"801","DOI":"10.1002\/ccd.25533","article-title":"Radiation reduction in pediatric and adult congenital patients during cardiac catheterization","volume":"84","author":"Mauriello","year":"2014","journal-title":"Catheter Cardiovasc Interv."},{"key":"10.1111\/chd.12356-BIB0019|chd12356-cit-0019","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1001\/jama.2009.54","article-title":"Estimated radiation dose associated with cardiac CT angiography","volume":"301","author":"Hausleiter","year":"2009","journal-title":"J Am Med Assoc."},{"key":"10.1111\/chd.12356-BIB0020|chd12356-cit-0020","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1542\/peds.2007-1910","article-title":"Radiation risk to children from computed tomography","volume":"120","author":"Brody","year":"2007","journal-title":"Pediatrics."},{"key":"10.1111\/chd.12356-BIB0021|chd12356-cit-0021","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1259\/bjr\/57217783","article-title":"Effective dose conversion factors in paediatric interventional cardiology","volume":"82","author":"Karambatsakidou","year":"2009","journal-title":"Br J Radiol."},{"key":"10.1111\/chd.12356-BIB0022|chd12356-cit-0022","volume-title":"Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2","author":"National Research Council","year":"2006"},{"key":"10.1111\/chd.12356-BIB0023|chd12356-cit-0023","doi-asserted-by":"crossref","first-page":"922","DOI":"10.1002\/ccd.23461","article-title":"The use of three-dimensional rotational angiography to assess the pulmonary circulation following cavo-pulmonary connection in patients with single ventricle","volume":"80","author":"Berman","year":"2012","journal-title":"Catheter Cardiovasc Interv."}],"container-title":["Congenital Heart Disease"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fchd.12356","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fchd.12356","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/onlinelibrary.wiley.com\/wol1\/doi\/10.1111\/chd.12356\/fullpdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,4,27]],"date-time":"2020-04-27T22:01:40Z","timestamp":1588024900000},"score":1,"resource":{"primary":{"URL":"http:\/\/doi.wiley.com\/10.1111\/chd.12356"}},"subtitle":["Radiation Protocol for Rotational Angiography"],"short-title":[],"issued":{"date-parts":[[2016,4,14]]},"references-count":23,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2016,12]]}},"URL":"https:\/\/doi.org\/10.1111\/chd.12356","archive":["Portico"],"relation":{},"ISSN":["1747-079X"],"issn-type":[{"value":"1747-079X","type":"print"}],"subject":[],"published":{"date-parts":[[2016,4,14]]}}}