{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,24]],"date-time":"2026-07-24T17:35:13Z","timestamp":1784914513154,"version":"3.55.0"},"reference-count":37,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2022,8,31]],"date-time":"2022-08-31T00:00:00Z","timestamp":1661904000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82071151"],"award-info":[{"award-number":["82071151"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005047","name":"Natural Science Foundation of Liaoning Province","doi-asserted-by":"publisher","award":["2020\u2010MS\u2010168"],"award-info":[{"award-number":["2020\u2010MS\u2010168"]}],"id":[{"id":"10.13039\/501100005047","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005047","name":"Natural Science Foundation of Liaoning Province","doi-asserted-by":"publisher","award":["2021\u2010MS\u20101760"],"award-info":[{"award-number":["2021\u2010MS\u20101760"]}],"id":[{"id":"10.13039\/501100005047","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clin Implant Dent Rel Res"],"published-print":{"date-parts":[[2022,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Introduction<\/jats:title><jats:p>Dental implant abutments play an important role in the health and aesthetics of soft and hard tissues around implants.<\/jats:p><\/jats:sec><jats:sec><jats:title>Purpose<\/jats:title><jats:p>To compare mechanical properties and marginal fit of prefabricated and customized dental implant abutments and provide references to evaluate the relationship between abutment choice and clinical indications.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Titanium abutments were randomly divided into prefabricated and customized abutments. Static and dynamic loads were applied according to ISO14801:2016. Mechanical properties, including fracture strength, fatigue strength, rotational torque value, and torque loss rate, were measured. The biological properties of the implant abutments were assessed using an internal marginal fit. The samples were sliced, and the internal marginal fit was examined using a scanning electron microscope before and after cyclic loading. The length of the tight contact was calculated at the level of the conical connection, lower internal connection, and screw threads. Microleakage was evaluated by immersing the samples in 1% methylene blue and measuring the absorbance.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The fracture strengths of the prefabricated abutments were greater than those of the customized abutments before and after cyclic loading. The average fatigue strengths of the prefabricated and customized abutments were 350 and 300\u2009N, respectively. The removal torque loss of the customized abutments was significantly greater than that of the prefabricated abutments. Significant differences were found in conical connection before loading, while the screw threads showed substantial differences between the two groups after loading. Microleakage in the customized abutments was significantly higher than that in the prefabricated abutments before and after loading.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Prefabricated abutments showed superior mechanical and biological properties compared with customized abutments in vitro, suggesting a greater risk of mechanical and biological complications occurring with the use of customized abutments. This study provides a reference for the clinical selection of implant abutments.<\/jats:p><\/jats:sec>","DOI":"10.1111\/cid.13130","type":"journal-article","created":{"date-parts":[[2022,8,31]],"date-time":"2022-08-31T11:54:55Z","timestamp":1661946895000},"page":"720-729","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Mechanical properties and marginal fit of prefabricated versus customized dental implant abutments: A comparative study"],"prefix":"10.1111","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2610-7781","authenticated-orcid":false,"given":"Mingchen","family":"Ma","sequence":"first","affiliation":[{"name":"Department of Oral Implantology School and Hospital of Stomatology, China Medical University  Shenyang Liaoning China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0892-4887","authenticated-orcid":false,"given":"Xuejing","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Oral Implantology School and Hospital of Stomatology, China Medical University  Shenyang Liaoning China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5945-7986","authenticated-orcid":false,"given":"Liyan","family":"Zou","sequence":"additional","affiliation":[{"name":"Department of Oral Implantology School and Hospital of Stomatology, China Medical University  Shenyang Liaoning China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2435-6194","authenticated-orcid":false,"given":"Jing","family":"He","sequence":"additional","affiliation":[{"name":"Department of Oral Implantology School and Hospital of Stomatology, China Medical University  Shenyang Liaoning China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6661-0552","authenticated-orcid":false,"given":"Baohong","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Oral Implantology School and Hospital of Stomatology, China Medical University  Shenyang Liaoning China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2022,8,31]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.7365"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12260"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2012.02547.x"},{"issue":"2","key":"e_1_2_9_5_1","first-page":"103","article-title":"Esthetic outcome of an immediately placed maxillary anterior single\u2010tooth implant restored with a custom\u2010made zirconia\u2010ceramic abutment and crown: a staged treatment","volume":"42","author":"Traini T","year":"2011","journal-title":"Quintessence Int."},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2019.12.023"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.11607\/prd.3184"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.12440"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.12982"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2012.00479.x"},{"issue":"3","key":"e_1_2_9_11_1","first-page":"620","article-title":"2010 Guidelines of the Academy of Osseointegration for the provision of dental implants and associated patient care","volume":"25","author":"Academy of Osseointegration","year":"2010","journal-title":"Int J Oral Maxillofac Implants."},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40729-017-0101-7"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2018.04.005"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1097\/ID.0000000000000481"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.5005\/jp-journals-10024-1952"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.22.10.107002"},{"issue":"3","key":"e_1_2_9_17_1","first-page":"537","article-title":"Marginal accuracy of three implant\u2010ceramic abutment configurations","volume":"27","author":"Baldassarri M","year":"2012","journal-title":"Int J Oral Maxillofac Implants."},{"issue":"3","key":"e_1_2_9_18_1","first-page":"455","article-title":"Microgap between zirconia abutments and titanium implants","volume":"25","author":"Baixe S","year":"2010","journal-title":"Int J Oral Maxillofac Implants."},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1563\/1548-1336(2003)029<0242:ISMATS>2.3.CO;2"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2010.02063.x"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-849X.2006.00078.x"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.5295"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2018.05.007"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2015.04.012"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2019.04.005"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1177\/00220345990780010301"},{"issue":"2","key":"e_1_2_9_27_1","first-page":"92","article-title":"Bite force and dentofacial morphology in men with severe dental attrition","volume":"102","author":"Waltimo A","year":"1994","journal-title":"Scand J Dent Res."},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1111\/joor.12817"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.1111\/jerd.12494"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2019.07.026"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-849X.2011.00756.x"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40729-021-00378-z"},{"key":"e_1_2_9_33_1","doi-asserted-by":"publisher","DOI":"10.2186\/jpr.JPR_D_20_00066"},{"key":"e_1_2_9_34_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13390"},{"key":"e_1_2_9_35_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13021"},{"key":"e_1_2_9_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2018.02.015"},{"key":"e_1_2_9_37_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12578"},{"key":"e_1_2_9_38_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.12651"}],"container-title":["Clinical Implant Dentistry and Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/cid.13130","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/cid.13130","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/cid.13130","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,19]],"date-time":"2023-08-19T16:17:23Z","timestamp":1692461843000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/cid.13130"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,31]]},"references-count":37,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,10]]}},"alternative-id":["10.1111\/cid.13130"],"URL":"https:\/\/doi.org\/10.1111\/cid.13130","archive":["Portico"],"relation":{},"ISSN":["1523-0899","1708-8208"],"issn-type":[{"value":"1523-0899","type":"print"},{"value":"1708-8208","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,31]]},"assertion":[{"value":"2022-06-21","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-08-20","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-08-31","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}