{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T12:14:53Z","timestamp":1790424893901,"version":"4.1.0"},"reference-count":31,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2024,5,29]],"date-time":"2024-05-29T00:00:00Z","timestamp":1716940800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clin Implant Dent Rel Res"],"published-print":{"date-parts":[[2024,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Introduction<\/jats:title><jats:p>Surgical guides are commonly used to assist with dental implant placement. This study investigated the effects of five sterilization and disinfection methods on the accuracy of implant guides.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Thirty surgical guides (five in each group) were designed and printed (with digital light processing technology) using different sterilization or disinfection methods categorized into six groups: hydrogen peroxide sterilization (group one); glutaraldehyde sterilization (group two); autoclaving (group three); plasma sterilization (group four); iodophor disinfection (group five); and blank group (group six). Verification was determined using three methods: distance and angle between the cross\u2010shaped marks, deformation after superimposing the guides, and displacement and axial changes in the virtual implant.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>After disinfection and sterilization, the guides in the autoclaving and iodophor groups showed a more pronounced color change and the guide\u00a0in the autoclaving group had visible cracks. More significant changes were observed in the H<jats:sub>2<\/jats:sub>O<jats:sub>2<\/jats:sub>, glutaraldehyde, autoclaving, and iodophor groups regarding deformation after superimposing the guides and the distance and angle between the cross\u2010shaped marks. The average labial deformation values (mm) of the first through fifth groups of guides were 0.283, 0.172, 0.289, 0.153, and 0.188, respectively. All groups were statistically different from the blank group for displacement and axial changes of the virtual implant (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.05).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The sizes of almost all surgical guides changed after sterilization and disinfection treatments, with between\u2010group differences. Plasma sterilization was more suitable for surgical guide sterilization because of the smaller deformations after treatment.<\/jats:p><\/jats:sec>","DOI":"10.1111\/cid.13350","type":"journal-article","created":{"date-parts":[[2024,5,29]],"date-time":"2024-05-29T11:58:31Z","timestamp":1716983911000},"page":"889-898","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Effects of sterilization and disinfection methods on digitally designed surgical implant guide accuracy: An in vitro study"],"prefix":"10.1111","volume":"26","author":[{"given":"Ruikun","family":"Li","sequence":"first","affiliation":[{"name":"Department of Implant Dentistry, West China Hospital of Stomatology Sichuan University  Chengdu China"},{"name":"State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University  Chengdu China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jie","family":"Zhu","sequence":"additional","affiliation":[{"name":"Department of Implant Dentistry, West China Hospital of Stomatology Sichuan University  Chengdu China"},{"name":"State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University  Chengdu China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuo","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Implant Dentistry, West China Hospital of Stomatology Sichuan University  Chengdu China"},{"name":"State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University  Chengdu China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xueyuan","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology the General Hospital of Western Theater Command  Chengdu China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Songhang","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Implant Dentistry, West China Hospital of Stomatology Sichuan University  Chengdu China"},{"name":"State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University  Chengdu China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2024,5,29]]},"reference":[{"key":"e_1_2_11_2_1","doi-asserted-by":"publisher","DOI":"10.18063\/ijb.v9i2.655"},{"key":"e_1_2_11_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2012.02484.x"},{"key":"e_1_2_11_4_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.5556"},{"key":"e_1_2_11_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.addma.2018.05.012"},{"key":"e_1_2_11_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joms.2005.05.156"},{"key":"e_1_2_11_7_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.2014suppl.g1.2"},{"issue":"2","key":"e_1_2_11_8_1","first-page":"298","article-title":"Effect of flapless surgery on pain experienced in implant placement using an image\u2010guided system","volume":"21","author":"Fortin T","year":"2006","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_11_9_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-017-0441-y"},{"key":"e_1_2_11_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2010.00275.x"},{"key":"e_1_2_11_11_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2012.02545.x"},{"key":"e_1_2_11_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2019.05.027"},{"key":"e_1_2_11_13_1","doi-asserted-by":"publisher","DOI":"10.1902\/jop.2011.110115"},{"issue":"6","key":"e_1_2_11_14_1","first-page":"8442","article-title":"Accuracy of different types of computer\u2010aided design\/computer\u2010aided manufacturing surgical guides for dental implant placement","volume":"8","author":"Geng W","year":"2015","journal-title":"Int J Clin Exp Med"},{"key":"e_1_2_11_15_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-020-1005-0"},{"key":"e_1_2_11_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00103-012-1548-6"},{"key":"e_1_2_11_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-031-22091-3_11"},{"issue":"2","key":"e_1_2_11_18_1","first-page":"274","article-title":"Microbial contamination and the sterilization\/disinfection of surgical guides used in the placement of endosteal implants","volume":"26","author":"Smith PN","year":"2011","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_11_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00784-007-0153-9"},{"key":"e_1_2_11_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/9781118928547.ch10"},{"key":"e_1_2_11_21_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00784-019-02926-9"},{"key":"e_1_2_11_22_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-022-02671-8"},{"key":"e_1_2_11_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2014.01.001"},{"key":"e_1_2_11_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jebdp.2012.10.001"},{"key":"e_1_2_11_25_1","doi-asserted-by":"publisher","DOI":"10.4103\/0975-7406.113306"},{"key":"e_1_2_11_26_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13799"},{"key":"e_1_2_11_27_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00784-012-0886-y"},{"key":"e_1_2_11_28_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.14158"},{"key":"e_1_2_11_29_1","doi-asserted-by":"publisher","DOI":"10.3390\/ma16155305"},{"key":"e_1_2_11_30_1","doi-asserted-by":"publisher","DOI":"10.2174\/1874210601812010072"},{"key":"e_1_2_11_31_1","doi-asserted-by":"publisher","DOI":"10.1097\/ID.0000000000000908"},{"key":"e_1_2_11_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joms.2011.04.013"}],"container-title":["Clinical Implant Dentistry and Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/cid.13350","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,17]],"date-time":"2025-01-17T07:57:10Z","timestamp":1737100630000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/cid.13350"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,29]]},"references-count":31,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2024,10]]}},"alternative-id":["10.1111\/cid.13350"],"URL":"https:\/\/doi.org\/10.1111\/cid.13350","archive":["Portico"],"relation":{},"ISSN":["1523-0899","1708-8208"],"issn-type":[{"value":"1523-0899","type":"print"},{"value":"1708-8208","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,29]]},"assertion":[{"value":"2024-01-16","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-05-16","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-05-29","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}