{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T03:41:40Z","timestamp":1792381300820,"version":"4.4.0"},"reference-count":43,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2025,2,7]],"date-time":"2025-02-07T00:00:00Z","timestamp":1738886400000},"content-version":"vor","delay-in-days":6,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clin Implant Dent Rel Res"],"published-print":{"date-parts":[[2025,2]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>To ensure long\u2010term implant success, it is crucial to understand the force transmission from the implant to the surrounding bone. In dentistry, bioengineering methods are applied to investigate these processes. The aim of this study was to analyze the influence of different implant geometries on the surface strain behavior of porcine mandibles under load using a 3D optical camera system in combination with digital image correlation. Four different implant types were subjected to a force of 200\u2009N in three different loading directions (axial, non\u2010axial 15\u00b0, and non\u2010axial 30\u00b0). Under axial loading, parallel\u2010walled implants exhibited lower surface strain values on the peri\u2010implant bone compared with tapered implants. However, when subjected to non\u2010axial loading, these parallel\u2010walled implants showed a substantial relative increase in strain by approximately a factor of 2.96 compared with axial conditions. At a 30\u00b0 non\u2010axial angle, long, tapered implants with a smaller diameter (BLX 3.75) produced lower peri\u2010implant bone strains than implants with larger diameters and shorter lengths, while short, tapered implants (BLT) demonstrated a lower relative increase in strain (factor ~1.49) from axial to non\u2010axial loading. Under non\u2010axial loading, long, tapered implants with a small diameter resulted in lower strains in the peri\u2010implant bone compared with implants with a larger diameter and shorter length. It was found that non\u2010axial loads lead to higher strains than axial loads. Therefore, the success of implantation could be significantly influenced by selecting an appropriate implant geometry and the correct angulation of the implant.<\/jats:p>","DOI":"10.1111\/cid.70003","type":"journal-article","created":{"date-parts":[[2025,2,7]],"date-time":"2025-02-07T06:49:56Z","timestamp":1738910996000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Influence of Implant Geometry on the Surface Strain Behavior of Peri\u2010Implant Bone: A\n                    <scp>3D<\/scp>\n                    Analysis"],"prefix":"10.1111","volume":"27","author":[{"given":"Moritz","family":"L\u00f6hlein","sequence":"first","affiliation":[{"name":"Dental Clinic 2, Department of Prosthodontics Universit\u00e4tsklinikum Erlangen  Erlangen Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Constantin","family":"Motel","sequence":"additional","affiliation":[{"name":"Dental Clinic 2, Department of Prosthodontics Universit\u00e4tsklinikum Erlangen  Erlangen Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manfred","family":"Wichmann","sequence":"additional","affiliation":[{"name":"Dental Clinic 2, Department of Prosthodontics Universit\u00e4tsklinikum Erlangen  Erlangen Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5900-1273","authenticated-orcid":false,"given":"Ragai Edward","family":"Matta","sequence":"additional","affiliation":[{"name":"Dental Clinic 2, Department of Prosthodontics Universit\u00e4tsklinikum Erlangen  Erlangen Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,2,7]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1177\/0022034518792567"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.3109\/02844316909036699"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/prd.12185"},{"issue":"1","key":"e_1_2_10_5_1","first-page":"3","article-title":"A 2003 Update of Bone Physiology and Wolff's Law for Clinicians","volume":"74","author":"Frost H. M.","year":"2009","journal-title":"Angle Orthodontist"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2018.10.014"},{"issue":"4","key":"e_1_2_10_7_1","first-page":"279","article-title":"Analysis of the Causes of Dental Implant Fracture: A Retrospective Clinical Study","volume":"49","author":"Stoichkov B.","year":"2018","journal-title":"Quintessence International"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.0909\u20108836..t01\u20102\u2010.x"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.2041\u20101626.2012.00162.x"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/ID.0b013e3182096c94"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.3390\/ijerph17134738"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0300-9785(81)80077-4"},{"issue":"2","key":"e_1_2_10_13_1","first-page":"69","article-title":"Integration of Screw Implants in the Rabbit: A 1\u2010Year Follow\u2010Up of Removal Torque of Titanium Implants","volume":"2","author":"Johansson C.","year":"1987","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2014.10.019"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2018.03.012"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.4797"},{"issue":"2","key":"e_1_2_10_17_1","first-page":"383","article-title":"Dental Implant Thread Pitch and Its Influence on the Osseointegration Process: An In\u00a0Vivo Comparison Study","volume":"27","author":"Orsini E.","year":"2012","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/ID.0b013e318065aa81"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1146\/annurev\u2010bioeng\u2010062117\u2010121139"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/joor.12345"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0033-1346682"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(90)90325-7"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1563\/1548-1336(1998)024<0080:EPOODI>2.3.CO;2"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11838\u2010013\u20100202\u2010y"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11838\u2010013\u20100206\u20107"},{"key":"e_1_2_10_26_1","volume-title":"Zahn\u00e4rztliche Prop\u00e4deutik","author":"Hellwig E.","year":"2005"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1067\/mpr.2001.115251"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2005.01132.x"},{"issue":"4","key":"e_1_2_10_29_1","first-page":"551","article-title":"Comparison of Implant Body Designs and Threaded Designs of Dental Implants: A 3\u2010Dimensional Finite Element Analysis","volume":"22","author":"Huang H.\u2010L.","year":"2007","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.simpat.2008.05.009"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2006.01360.x"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.2001.012003207.x"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12059"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.3390\/ma17092161"},{"key":"e_1_2_10_35_1","unstructured":"\u201cStraumann Dental Implant System\u2014Basisinformationen \u201d 2019 https:\/\/www.straumann.com\/content\/dam\/media\u2010center\/straumann\/de\u2010de\/documents\/brochure\/technical\u2010information\/straumann_de151754_dental_implant_system.pdf."},{"key":"e_1_2_10_36_1","unstructured":"\u201cStraumann BLX Implantatsystem\u2014Basisinformationen \u201d 2022 https:\/\/www.straumann.com\/content\/dam\/media\u2010center\/straumann\/de\/documents\/brochure\/technical\u2010information\/702115\u2010de_low.pdf."},{"key":"e_1_2_10_37_1","volume-title":"49th International Scientific Conference","author":"Jan\u00ed\u010dek P.","year":"2011"},{"key":"e_1_2_10_38_1","unstructured":"B.Gorny \u201cEinsatzm\u00f6glichkeiten und Anwendungsgrenzen der Digitalen Bildkorrelation zur Fr\u00fchdetektion Struktureller und Funktioneller Sch\u00e4digungen und Versagensvorhersage in Metallischen Werkstoffen Werkstoffverbunden und Verbundwerkstoffen\u201d (Diss. Universit\u00e4t Paderborn Paderborn 2013)."},{"key":"e_1_2_10_39_1","doi-asserted-by":"publisher","DOI":"10.1080\/10255840600837074"},{"key":"e_1_2_10_40_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.heliyon.2024.e26876"},{"key":"e_1_2_10_41_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365\u20102842.2002.00891.x"},{"key":"e_1_2_10_42_1","first-page":"207","article-title":"Die Knochenresorption an der Eintrittstelle Osseointegrierter Implantate\u2014Ein Biomechanisches Ph\u00e4nomen. Eine Finite\u2010Element\u2010Studie","volume":"86","author":"Mailath G.","year":"1989","journal-title":"Z Stomatol"},{"issue":"4","key":"e_1_2_10_43_1","first-page":"333","article-title":"Numerical Investigations of the Influence of Implant Shape on Stress Distribution in the Jaw Bone","volume":"4","author":"Siegele D.","year":"1989","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_10_44_1","doi-asserted-by":"publisher","DOI":"10.3390\/prosthesis2030019"}],"container-title":["Clinical Implant Dentistry and Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/cid.70003","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/cid.70003","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/cid.70003","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T03:23:43Z","timestamp":1792380223000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/cid.70003"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2]]},"references-count":43,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,2]]}},"alternative-id":["10.1111\/cid.70003"],"URL":"https:\/\/doi.org\/10.1111\/cid.70003","archive":["Portico"],"relation":{},"ISSN":["1523-0899","1708-8208"],"issn-type":[{"value":"1523-0899","type":"print"},{"value":"1708-8208","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2]]},"assertion":[{"value":"2024-11-04","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-14","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-02-07","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70003"}}