{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T18:09:17Z","timestamp":1757614157977,"version":"3.44.0"},"reference-count":40,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2025,8,20]],"date-time":"2025-08-20T00:00:00Z","timestamp":1755648000000},"content-version":"vor","delay-in-days":19,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clin Implant Dent Rel Res"],"published-print":{"date-parts":[[2025,8]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:sec><jats:title>Statement of Problem<\/jats:title><jats:p>Due to its biomechanical advantages, the Novaloc attachment system with angulated abutments has gained popularity in two\u2010implant\u2010supported mandibular overdentures. However, limited data are available on how implant position, angulation, and arch form affect stress and strain distribution within the attachment system. Understanding these factors is essential for optimizing prosthetic longevity and clinical outcomes.<\/jats:p><\/jats:sec><jats:sec><jats:title>Purpose<\/jats:title><jats:p>This finite element analysis (FEA) study aimed to evaluate the impact of implant position, angulation, and mandibular arch form on stress and strain distribution in Novaloc overdenture attachment systems.<\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and Methods<\/jats:title><jats:p>A computed tomography (CT) scan of an edentulous mandible was segmented using 3D Slicer software, and three mandibular arch forms (ovoid, tapered, square) were modeled in a three\u2010dimensional FEA environment (ANSYS Workbench, ANSYS Inc.). Implants and the Novaloc attachment system were designed and integrated using ANSYS SpaceClaim software. Finite element models were generated with implant angulations of 0\u00b0, 15\u00b0, 40\u00b0, and 60\u00b0, positioned at three locations: lateral incisor region, midpoint between lateral incisor and canine, and canine region. Vertical and oblique loads were applied in the first molar region to simulate masticatory forces. Von Mises stress distribution and dislocation forces were recorded and analyzed.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The highest stresses were observed in canine\u2010positioned implants within tapered arches under 30\u00b0 oblique loading. Stresses in Novaloc abutments (36.85\u201340.27\u2009MPa) and inserts (13.89\u201315.31\u2009MPa) approached their mechanical limits. Increasing implant angulation up to a total of 60\u00b0 between implants increased stresses on the abutments while reducing stresses and displacement in the inserts. Oblique forces (30\u00b0) generated higher stresses compared to vertical and 45\u00b0 oblique forces. Among mandibular arch forms, stress distribution followed the pattern: tapered\u2009&gt;\u2009ovoid\u2009&gt;\u2009square.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Anterior implant positioning in two\u2010implant\u2010supported overdentures resulted in more favorable stress distribution within the Novaloc attachment system. Implant angulations up to 60\u00b0 had a minimal effect on stress patterns, suggesting that angulated abutments may be a viable alternative in cases with anatomical limitations. These findings provide biomechanical insights that may aid in optimizing implant placement and attachment selection in clinical practice.<\/jats:p><\/jats:sec>","DOI":"10.1111\/cid.70082","type":"journal-article","created":{"date-parts":[[2025,8,20]],"date-time":"2025-08-20T14:12:27Z","timestamp":1755699147000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Finite Element Analysis of Novaloc Attachments at Extreme Angulations and Arch Forms: A Specification Study"],"prefix":"10.1111","volume":"27","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-4149-2061","authenticated-orcid":false,"given":"Sultan Merve","family":"U\u00e7ar","sequence":"first","affiliation":[{"name":"Department of Prosthodontics, Faculty of Dentistry Istanbul Biruni University  Istanbul Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9321-1031","authenticated-orcid":false,"given":"Rafat","family":"Sasany","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Faculty of Dentistry Istanbul Biruni University  Istanbul Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-3368-8712","authenticated-orcid":false,"given":"Hanan","family":"Al\u2010Johani","sequence":"additional","affiliation":[{"name":"Department of Restorative Dentistry, Faculty of Dentistry King Abdulaziz University  Jeddah Saudi Arabia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,8,20]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpor.2017.06.004"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1177\/154405910608500613"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1741-2358.2002.00003.x"},{"key":"e_1_2_8_5_1","first-page":"310","article-title":"Mandibular Overdentures Retained by Two Implants: 10\u2010Year Results From a Crossover Clinical Trial Comparing Ball\u2010Socket and Bar\u2010Clip Attachments","volume":"23","author":"Cune M.","year":"2010","journal-title":"International Journal of Prosthodontics"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2022.08.004"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1038\/sj.bdj.2009.728"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.24815\/jds.v5i1.18426"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/ID.0b013e3181fa4267"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(03)00158-6"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1177\/154411130401500406"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2010.08.002"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(96)90249-8"},{"volume-title":"Dental Implant Prosthetics\u2010E\u2010Book","year":"2004","author":"Misch C. E.","key":"e_1_2_8_14_1"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2016.10.037"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.3390\/ma15093248"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1177\/23800844221124083"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2842.2004.01407.x"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1067\/mpr.2000.109378"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2009.00154.x"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12643"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13567"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.6023"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2017.07.016"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.34172\/joddd.2023.40483"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.4322\/bds.2022.e3355"},{"key":"e_1_2_8_27_1","first-page":"132","article-title":"Stress Distribution in Peri\u2010Implant Bone in the Replacement of Molars With One or Two Implants: A Finite Element Analysis","volume":"24","author":"Mozaffari A.","year":"2023","journal-title":"Journal of Dentistry"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-023-03016-9"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2021.07.025"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2003.10.011"},{"key":"e_1_2_8_31_1","first-page":"e69","article-title":"Effect of Implant Position, Angulation, and Attachment Height on Peri\u2010Implant Bone Stress Associated With Mandibular Two\u2010Implant Overdentures: A Finite Element Analysis","volume":"27","author":"Hong H. R.","year":"2012","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_8_32_1","doi-asserted-by":"publisher","DOI":"10.15212\/bioi-2021-0012"},{"key":"e_1_2_8_33_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40510-018-0233-1"},{"key":"e_1_2_8_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajodo.2010.11.004"},{"key":"e_1_2_8_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2022.06.007"},{"key":"e_1_2_8_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.sdentj.2015.03.001"},{"key":"e_1_2_8_37_1","doi-asserted-by":"publisher","DOI":"10.4103\/1735-3327.245234"},{"key":"e_1_2_8_38_1","doi-asserted-by":"publisher","DOI":"10.3889\/oamjms.2017.047"},{"key":"e_1_2_8_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.identj.2025.01.014"},{"key":"e_1_2_8_40_1","doi-asserted-by":"publisher","DOI":"10.11607\/ijp.4995"},{"key":"e_1_2_8_41_1","doi-asserted-by":"publisher","DOI":"10.4103\/jips.jips_110_17"}],"container-title":["Clinical Implant Dentistry and Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/cid.70082","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,5]],"date-time":"2025-09-05T04:32:04Z","timestamp":1757046724000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/cid.70082"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8]]},"references-count":40,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,8]]}},"alternative-id":["10.1111\/cid.70082"],"URL":"https:\/\/doi.org\/10.1111\/cid.70082","archive":["Portico"],"relation":{},"ISSN":["1523-0899","1708-8208"],"issn-type":[{"type":"print","value":"1523-0899"},{"type":"electronic","value":"1708-8208"}],"subject":[],"published":{"date-parts":[[2025,8]]},"assertion":[{"value":"2025-04-20","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-08-04","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-08-20","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70082"}}