{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T15:35:41Z","timestamp":1789659341736,"version":"4.0.1"},"reference-count":26,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2015,12,30]],"date-time":"2015-12-30T00:00:00Z","timestamp":1451433600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clinical Oral Implants Res"],"published-print":{"date-parts":[[2016,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Objectives<\/jats:title><jats:p>To evaluate the adjustment of structures designed from a digital impression of implants obtained by cone\u2010beam computerized tomography (<jats:styled-content style=\"fixed-case\">CBCT<\/jats:styled-content>).<\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and methods<\/jats:title><jats:p>Thirty implants were placed in five edentulous mandibles of fresh cadaver heads, six per mandible. Special scan bodies were screwed in the implants and a <jats:styled-content style=\"fixed-case\">CBCT<\/jats:styled-content> was taken. <jats:styled-content style=\"fixed-case\">DICOM<\/jats:styled-content> images were converted to <jats:styled-content style=\"fixed-case\">STL<\/jats:styled-content> and digitally processed to obtain a digital model of the implants. A Cr\u2010Co structure was designed and milled for each mandible, and the adjustment was assessed as in a real clinical situation: passivity while screwing, radiographic fitting, optical fitting, and probing.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Good adjustment was found in three of the structures, and only slight discrepancies were found in the other two.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Cone\u2010beam computerized tomography might be a valid impression\u2010taking method in full\u2010mouth rehabilitations with implants. Further evaluations are needed with more implant and <jats:styled-content style=\"fixed-case\">CBCT<\/jats:styled-content> systems. The radiation dose might be considered when deciding to use this impression system. The types of patients appropriate for this treatment option should also be determined to fulfill the principles of the <jats:styled-content style=\"fixed-case\">ALARA<\/jats:styled-content> law.<\/jats:p><\/jats:sec>","DOI":"10.1111\/clr.12754","type":"journal-article","created":{"date-parts":[[2015,12,30]],"date-time":"2015-12-30T09:14:41Z","timestamp":1451466881000},"page":"1407-1413","source":"Crossref","is-referenced-by-count":13,"title":["Digital implant impressions by cone\u2010beam computerized tomography: a pilot study"],"prefix":"10.1111","volume":"27","author":[{"given":"Cristina","family":"Corominas\u2010Delgado","sequence":"first","affiliation":[{"name":"Department of Restorative Dentistry School of Dentistry Universitat Internacional de Catalunya Barcelona Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9","family":"Espona","sequence":"additional","affiliation":[{"name":"Department of Periodontology School of Dentistry Universitat Internacional de Catalunya Barcelona Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marian","family":"Lorente\u2010Gasc\u00f3n","sequence":"additional","affiliation":[{"name":"Department of Anatomy School of Medicine Universitat Internacional de Catalunya Barcelona Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco","family":"Real\u2010Voltas","sequence":"additional","affiliation":[{"name":"Department of Restorative Dentistry School of Dentistry Universitat Internacional de Catalunya Barcelona Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miguel","family":"Roig","sequence":"additional","affiliation":[{"name":"Department of Restorative Dentistry School of Dentistry Universitat Internacional de Catalunya Barcelona Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Santiago","family":"Costa\u2010Palau","sequence":"additional","affiliation":[{"name":"Department of Restorative Dentistry School of Dentistry Universitat Internacional de Catalunya Barcelona Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2015,12,30]]},"reference":[{"key":"e_1_2_6_2_1","first-page":"506","article-title":"Assessing the fit of implant fixed prostheses: a critical review","volume":"25","author":"Abduo J.","year":"2010","journal-title":"The International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-849X.2011.00709.x"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1177\/154405910308200316"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(98)70108-8"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1002\/cncr.26625"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijom.2009.02.028"},{"key":"e_1_2_6_8_1","first-page":"226","article-title":"Accuracy of impression and pouring techniques for an implant\u2010supported prosthesis","volume":"23","author":"Del'Acqua M.A.","year":"2008","journal-title":"The International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_6_9_1","first-page":"920","article-title":"Volumetric determination of the amount of misfit in CAD\/CAM and cast implant frameworks: a multicenter laboratory study","volume":"25","author":"Drago C.","year":"2010","journal-title":"The International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.12124"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2842.1998.00261.x"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2012.02441.x"},{"key":"e_1_2_6_13_1","first-page":"749","article-title":"CBCT technology for diagnosis and treatment planning: what general practitioners should consider","volume":"35","author":"Jansen C.E.","year":"2014","journal-title":"Compendium of Continuing Education in Dentistry"},{"key":"e_1_2_6_14_1","first-page":"527","article-title":"Microbial leakage and marginal fit of the implant\u2010abutment interface","volume":"12","author":"Jansen V.K.","year":"1997","journal-title":"The International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(99)70229-5"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1902\/jop.2002.73.10.1111"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2012.02430.x"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.4047\/jap.2010.2.1.25"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(08)60208-5"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2008.06.002"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/16770531"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/26310390"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1097\/00008505-200104000-00003"},{"issue":"1","key":"e_1_2_6_24_1","first-page":"e63","article-title":"Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in\u00a0vitro comparative study","volume":"12","author":"Sorrentino R.","year":"2010","journal-title":"Clinical Implant Dentistry & Related Research"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.oooo.2012.03.005"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.1995.060103.x"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12234"}],"container-title":["Clinical Oral Implants Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fclr.12754","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fclr.12754","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/clr.12754","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T17:58:59Z","timestamp":1695491939000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/clr.12754"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,12,30]]},"references-count":26,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2016,11]]}},"alternative-id":["10.1111\/clr.12754"],"URL":"https:\/\/doi.org\/10.1111\/clr.12754","archive":["Portico"],"relation":{},"ISSN":["0905-7161","1600-0501"],"issn-type":[{"value":"0905-7161","type":"print"},{"value":"1600-0501","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,12,30]]}}}