{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T18:50:17Z","timestamp":1783363817149,"version":"3.54.6"},"reference-count":35,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2019,8,20]],"date-time":"2019-08-20T00:00:00Z","timestamp":1566259200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clinical Oral Implants Res"],"published-print":{"date-parts":[[2019,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Objectives<\/jats:title><jats:p>To compare the three\u2010dimensional changes in quantity and morphology following clinical adjustment of a posterior single implant crown between chairside digital workflow (test) and hybrid digital workflow (control).<\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and Methods<\/jats:title><jats:p>A total of 33 participants were included for single\u2010tooth replacement with screw\u2010retained crowns in posterior sites of either the maxillary or mandible. A total of 17 participants were carried to a chairside digital workflow, receiving monolithic lithium disilicate (LS2)\u2010crowns (test), while the remaining 16 participants were fitted with CAD\/CAM\u2010fabricated zirconia superstructures and hand\u2010layered ceramic veneering crowns (control). As each crown underwent intraoral scanning (3Shape TRIOS Color, 3Shape), 3D digital models were rendered. These scans were taken both before and after try\u2010in. Clinical adjustment dimensional changes were measured by superimposing the optical scans of models within a reverse software (Geomagic Control 2014). Adjustment counts and amounts (from vertical dimension) between two workflows were assessed and compared. Time consumption was recorded for efficiency analysis.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>All patients were successfully treated in both groups. The median maximum vertical adjustment (taking both occlusal and interproximal surfaces into consideration) was 237\u00a0\u03bcm\u00a0\u00b1\u00a0112 in the test group and 485\u00a0\u03bcm\u00a0\u00b1\u00a0195 in the control group (<jats:italic>p<\/jats:italic>\u00a0&lt;\u00a0.0001), respectively. The median adjustment count was 2.00\u00a0\u00b1\u00a01.09 in test group and 3.00\u00a0\u00b1\u00a01.05 in control group (<jats:italic>p<\/jats:italic>\u00a0=\u00a0.001), respectively. The total active working time\/ total time for two workflows was 92.3\/113.7\u00a0min for the test group and 146.3\/676.3\u00a0min for the control group, respectively.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The test group showed fewer adjustments and apparent precision on the occlusal surface compared with the control group with only a fifth of the consumption of a hybrid workflow.<\/jats:p><\/jats:sec>","DOI":"10.1111\/clr.13519","type":"journal-article","created":{"date-parts":[[2019,7,29]],"date-time":"2019-07-29T22:31:34Z","timestamp":1564439494000},"page":"1059-1066","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":46,"title":["Quantitative clinical adjustment analysis of posterior single implant crown in a chairside digital workflow: A randomized controlled trial"],"prefix":"10.1111","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0701-3771","authenticated-orcid":false,"given":"Yifan","family":"Zhang","sequence":"first","affiliation":[{"name":"Department of Oral Implantology Peking University School and Hospital of Stomatology &amp; National Clinical Research Center for Oral Disease &amp; National Engineering Laboratory for Digital and Material Technology of Stomatology &amp; Beijing Key Laboratory of Digital Stomatology Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiehua","family":"Tian","sequence":"additional","affiliation":[{"name":"Department of Oral Implantology Peking University School and Hospital of Stomatology &amp; National Clinical Research Center for Oral Disease &amp; National Engineering Laboratory for Digital and Material Technology of Stomatology &amp; Beijing Key Laboratory of Digital Stomatology Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4844-0860","authenticated-orcid":false,"given":"Donghao","family":"Wei","sequence":"additional","affiliation":[{"name":"Department of Oral Implantology Peking University School and Hospital of Stomatology &amp; National Clinical Research Center for Oral Disease &amp; National Engineering Laboratory for Digital and Material Technology of Stomatology &amp; Beijing Key Laboratory of Digital Stomatology Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ping","family":"Di","sequence":"additional","affiliation":[{"name":"Department of Oral Implantology Peking University School and Hospital of Stomatology &amp; National Clinical Research Center for Oral Disease &amp; National Engineering Laboratory for Digital and Material Technology of Stomatology &amp; Beijing Key Laboratory of Digital Stomatology Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ye","family":"Lin","sequence":"additional","affiliation":[{"name":"Department of Oral Implantology Peking University School and Hospital of Stomatology &amp; National Clinical Research Center for Oral Disease &amp; National Engineering Laboratory for Digital and Material Technology of Stomatology &amp; Beijing Key Laboratory of Digital Stomatology Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2019,8,20]]},"reference":[{"issue":"2","key":"e_1_2_9_2_1","first-page":"29","article-title":"The dimensional accuracy of four impression techniques with the use of addition silicone impression materials","volume":"18","author":"Al\u2010Bakri I. A.","year":"2007","journal-title":"The Journal of Clinical Dentistry"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00784-017-2198-8"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.11607\/ijp.5938"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2015.09.011"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(13)60028-1"},{"issue":"86","key":"e_1_2_9_7_1","first-page":"e51374","article-title":"Accuracy in dental medicine, a new way to measure trueness and precision","author":"Ender A.","year":"2014","journal-title":"Journal of Visualized Experiments"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00784-015-1641-y"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0158800"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00784-012-0795-0"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12270"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12476"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.3963"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12600"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12753"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.12472"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12955"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13360"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.12377"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2012.02547.x"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.2014suppl.g2.3"},{"issue":"3","key":"e_1_2_9_22_1","first-page":"257","article-title":"Final restoration of implants with a hybrid ceramic superstructure","volume":"19","author":"Kurbad A.","year":"2016","journal-title":"International Journal of Computerized Dentistry"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1563\/AAID-JOI-D-13-00132"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12375"},{"issue":"2","key":"e_1_2_9_25_1","first-page":"394","article-title":"Prospective clinical evaluation of 307 single\u2010tooth Morse taper\u2010connection implants: A multicenter study","volume":"25","author":"Mangano C.","year":"2010","journal-title":"International Journal of Oral and Maxillofacial Implants"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1155\/2018\/5325032"},{"issue":"1","key":"e_1_2_9_27_1","first-page":"11","article-title":"Accuracy testing of a new intraoral 3D camera","volume":"12","author":"Mehl A.","year":"2009","journal-title":"International Journal of Computerized Dentistry"},{"issue":"1","key":"e_1_2_9_28_1","first-page":"23","article-title":"3D monitoring and quality control using intraoral optical camera systems","volume":"16","author":"Mehl A.","year":"2013","journal-title":"International Journal of Computerized Dentistry"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13300"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2015.04.003"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.12508"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1038\/sj.bdj.2013.1146"},{"key":"e_1_2_9_33_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2007.01382.x"},{"key":"e_1_2_9_34_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.2013.g2"},{"key":"e_1_2_9_35_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12234"},{"issue":"2","key":"e_1_2_9_36_1","first-page":"123","article-title":"Chairside systems: A current review","volume":"20","author":"Zaruba M.","year":"2017","journal-title":"International Journal of Computerized Dentistry"}],"container-title":["Clinical Oral Implants Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fclr.13519","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/clr.13519","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/clr.13519","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/clr.13519","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,9]],"date-time":"2023-09-09T03:55:45Z","timestamp":1694231745000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/clr.13519"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,20]]},"references-count":35,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2019,11]]}},"alternative-id":["10.1111\/clr.13519"],"URL":"https:\/\/doi.org\/10.1111\/clr.13519","archive":["Portico"],"relation":{},"ISSN":["0905-7161","1600-0501"],"issn-type":[{"value":"0905-7161","type":"print"},{"value":"1600-0501","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8,20]]},"assertion":[{"value":"2019-04-26","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-07-08","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-08-20","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}