{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T12:11:25Z","timestamp":1791807085711,"version":"4.3.4"},"reference-count":41,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2021,8,11]],"date-time":"2021-08-11T00:00:00Z","timestamp":1628640000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clinical Oral Implants Res"],"published-print":{"date-parts":[[2021,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Objective<\/jats:title><jats:p>To evaluate the influence of artificial aging on the transformation propagation and fracture resistance of zirconia implants.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>One\u2010piece (with integrated implant abutment, 1P; regular diameter [4.1mm]; <jats:italic>n\u00a0=<\/jats:italic>\u00a016) and two\u2010piece (with separate implant abutment, 2P; wide diameter [5\u00a0mm]; <jats:italic>n\u00a0=<\/jats:italic>\u00a016) zirconia implants were embedded according to ISO 14801. A two\u2010piece titanium\u2013zirconium implant (Ti\u2010Zr; 4.1\u00a0mm diameter) served as a control (<jats:italic>n\u00a0=<\/jats:italic>\u00a016). One subgroup (<jats:italic>n\u00a0=<\/jats:italic>\u00a08) of each system was simultaneously dynamically loaded (10<jats:sup>7<\/jats:sup> cycles; 98N) and hydrothermally aged (85\u00b0C, 58\u00a0days), while the other subgroup (<jats:italic>n\u00a0=<\/jats:italic>\u00a08) remained untreated. Finally, specimens were statically loaded to fracture. Potential crystal phase transformation was examined at cross sections using scanning electron microscopy (SEM). A multivariate linear regression model was applied for statistical analyses.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The fracture resistance of 1P (1,117 [SD = 38] <jats:italic>N<\/jats:italic>; loaded\/aged: 1,009 [60] <jats:italic>N<\/jats:italic>), 2P (850 [36] <jats:italic>N<\/jats:italic>; loaded\/aged: 799 [84] <jats:italic>N<\/jats:italic>), and Ti\u2010Zr implants (1,338 [205] <jats:italic>N<\/jats:italic>; loaded\/aged: 1,319 [247] <jats:italic>N<\/jats:italic>) was not affected significantly by loading\/aging (<jats:italic>p<\/jats:italic>\u00a0=\u00a0.171). However, when comparing the systems, they revealed significant differences independent of loading\/aging (<jats:italic>p<\/jats:italic>\u00a0\u2264\u00a0.001). Regarding the crystal structure, a transformation zone was observed in SEM images of 1P only after aging, while 2P showed a transformation zone even before aging. After hydrothermal treatment, an increase of this monoclinic layer was observed in both systems.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The Ti\u2010Zr control implant showed higher fracture resistance compared to both zirconia implants. Loading\/aging had no significant impact on the fracture resistance of both zirconia implants. The wide\u2010body 2P zirconia implant was weaker than the regular body 1P implant.<\/jats:p><\/jats:sec>","DOI":"10.1111\/clr.13825","type":"journal-article","created":{"date-parts":[[2021,8,5]],"date-time":"2021-08-05T18:43:45Z","timestamp":1628189025000},"page":"1288-1298","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Fracture resistance and crystal phase transformation of a one\u2010 and a two\u2010piece zirconia implant with and without simultaneous loading and aging\u2014An <i>in vitro<\/i> study"],"prefix":"10.1111","volume":"32","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0011-4134","authenticated-orcid":false,"given":"Felix","family":"Burkhardt","sequence":"first","affiliation":[{"name":"Department of Prosthetic Dentistry Faculty of Medicine Medical Center \u2010 University of Freiburg, Center for Dental Medicine University of Freiburg Freiburg Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1702-1679","authenticated-orcid":false,"given":"Benedikt C.","family":"Spies","sequence":"additional","affiliation":[{"name":"Department of Prosthetic Dentistry Faculty of Medicine Medical Center \u2010 University of Freiburg, Center for Dental Medicine University of Freiburg Freiburg Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lennart","family":"Riemer","sequence":"additional","affiliation":[{"name":"Department of Prosthetic Dentistry Faculty of Medicine Medical Center \u2010 University of Freiburg, Center for Dental Medicine University of Freiburg Freiburg Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erik","family":"Adolfsson","sequence":"additional","affiliation":[{"name":"Swerea IVF AB M\u00f6lndal Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sam","family":"Doerken","sequence":"additional","affiliation":[{"name":"Medical Center \u2010 University of Freiburg Institute for Medical Biometry and Statistics Faculty of Medicine University of Freiburg Freiburg Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7095-4190","authenticated-orcid":false,"given":"Ralf\u2010Joachim","family":"Kohal","sequence":"additional","affiliation":[{"name":"Department of Prosthetic Dentistry Faculty of Medicine Medical Center \u2010 University of Freiburg, Center for Dental Medicine University of Freiburg Freiburg Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2021,8,11]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13581"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2842.2005.01509.x"},{"key":"e_1_2_9_4_1","first-page":"290","article-title":"Implant neck configurations for preservation of marginal bone level: A systematic review","volume":"26","author":"Bateli M.","year":"2011","journal-title":"The International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1151-2916.1992.tb07832.x"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.3390\/ma13030562"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-018-0636-x"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2018.03.006"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2014.07.004"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2004.01.002"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2014.12.013"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2012.07.001"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1177\/00220345000790071501"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2011.02206.x"},{"key":"e_1_2_9_15_1","first-page":"1","volume-title":"Implants for surgers\u2010ceramic materials based on yttria\u2010stabilized tetragonal zirconia (Y\u2010TZP)","author":"ISO 13356","year":"2008"},{"key":"e_1_2_9_16_1","first-page":"1","volume-title":"Dentistry\u2010implant\u2010dynamic fatigue test for endosseous dental implants","author":"ISO 14801","year":"2008"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2842.2007.01681.x"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm9082585"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13576"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF00809059"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2012.02453.x"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2015.09.014"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2019.103423"},{"key":"e_1_2_9_24_1","first-page":"481","article-title":"In vivo forces on implants influenced by occlusal scheme and food consistency","volume":"16","author":"Morneburg T. R.","year":"2003","journal-title":"The International Journal of Prosthodontics"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actamat.2010.09.047"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(98)00010-6"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1177\/0022034516664043"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.31064"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2016.03.028"},{"key":"e_1_2_9_30_1","first-page":"232","article-title":"In vivo horizontal bending moments on implants","volume":"13","author":"Richter E. J.","year":"1998","journal-title":"The International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2014.09.002"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2013.01.007"},{"key":"e_1_2_9_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2018.11.033"},{"key":"e_1_2_9_34_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12269"},{"key":"e_1_2_9_35_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2005.tb00070.x"},{"key":"e_1_2_9_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2017.07.009"},{"key":"e_1_2_9_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpor.2017.07.003"},{"key":"e_1_2_9_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2018.08.290"},{"key":"e_1_2_9_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2017.06.002"},{"key":"e_1_2_9_40_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2015.07.005"},{"key":"e_1_2_9_41_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2014.12.013"},{"key":"e_1_2_9_42_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12339"}],"container-title":["Clinical Oral Implants Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/clr.13825","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/clr.13825","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/clr.13825","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,25]],"date-time":"2023-08-25T21:24:48Z","timestamp":1692998688000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/clr.13825"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,11]]},"references-count":41,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2021,11]]}},"alternative-id":["10.1111\/clr.13825"],"URL":"https:\/\/doi.org\/10.1111\/clr.13825","archive":["Portico"],"relation":{},"ISSN":["0905-7161","1600-0501"],"issn-type":[{"value":"0905-7161","type":"print"},{"value":"1600-0501","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,8,11]]},"assertion":[{"value":"2021-03-16","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-07-13","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-08-11","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}