{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T23:23:44Z","timestamp":1791329024573,"version":"4.3.1"},"reference-count":46,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2023,7,24]],"date-time":"2023-07-24T00:00:00Z","timestamp":1690156800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clinical Oral Implants Res"],"published-print":{"date-parts":[[2023,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>To assess accuracy of intraoral optical scanning (IOS) and stereophotogrammetry (SPG), complete\u2010arch digital implant impressions in vivo.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>\n                      Consecutive patients needing implant\u2010supported screw\u2010retained zirconia complete\u2010arch fixed\u2010dental prostheses (ISZ\u2010FDP) were recruited. For each patient, three impressions were taken: IOS, SPG (tests), and open\u2010tray plaster (reference). Linear (\u0394\n                      <jats:italic>X<\/jats:italic>\n                      , \u0394\n                      <jats:italic>Y<\/jats:italic>\n                      , and \u0394\n                      <jats:italic>Z<\/jats:italic>\n                      ), three\u2010dimensional (\u0394EUC), and angular deviations (\u0394ANGLE) were evaluated and stratified according to scanning technology for each implant. Potential effects of impression device (IOS and SPG), arch (maxilla and mandible), and implant number (4 and 6) were evaluated through multivariable analysis. Significance level was set at .05.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 11 complete arches (5 maxillae, 6 mandibles) in 11 patients were rehabilitated with ISZ\u2010FDPs supported by 4 (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20098) and 6 implants (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20093). A total of 50 implants and 100 implant positions were captured by two investigated devices and compared to respective reference (mean \u0394EUC IOS 137.2, SPG 87.6\u2009\u03bcm; mean \u0394ANGLE 0.79, 0.38\u00b0). Differences between measurements (SPG\u2010IOS) were computed for each implant, with negative values indicating better SPG accuracy. Significant mean \u0394EUC difference of \u221249.60\u2009\u03bcm (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u2009.0143; SD 138.15) and mean \u0394ANGLE difference of \u22120.40\u00b0 (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u2009.0001; SD 0.65) were observed in favor of SPG. Multivariable analysis showed significant effect on \u0394EUC (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u2009.0162) and \u0394ANGLE (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u2009.0001) only for impression devices, with SPG performing better.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>SPG experienced significantly higher linear and angular accuracy. No effect of type of arch or implant number was detected. Higher extreme deviations were experienced for IOS. SPG can be feasible for complete\u2010arch digital impressions with caution, and rigid prototype try\u2010in is recommended before screw\u2010retained prosthesis manufacturing.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/clr.14141","type":"journal-article","created":{"date-parts":[[2023,7,24]],"date-time":"2023-07-24T03:41:08Z","timestamp":1690170068000},"page":"1106-1117","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":56,"title":["Accuracy of complete\u2010arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective comparative study"],"prefix":"10.1111","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3052-8186","authenticated-orcid":false,"given":"Alessandro","family":"Pozzi","sequence":"first","affiliation":[{"name":"Department of Clinical Sciences and Translational Medicine, School of Dentistry University of Tor Vergata  Rome Italy"},{"name":"Departement of Restorative Sciences Dental College of Georgia, Augusta University  Augusta USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2442-1091","authenticated-orcid":false,"given":"Paolo","family":"Carosi","sequence":"additional","affiliation":[{"name":"Department of Chemical Science and Technologies, PhD in Materials for Health, Environment and Energy \u2013 Dentistry University of Rome Tor Vergata  Rome Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6386-594X","authenticated-orcid":false,"given":"German O.","family":"Gallucci","sequence":"additional","affiliation":[{"name":"Department of Restorative Dentistry and Biomaterials Sciences Harvard School of Dental Medicine  Boston Massachusetts USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katalin","family":"Nagy","sequence":"additional","affiliation":[{"name":"Department of Oral Surgery, Faculty of Dentistry University of Szeged Tisza L. Krt  Szeged Hungary"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alessandra","family":"Nardi","sequence":"additional","affiliation":[{"name":"Department of Mathematics University of Rome Tor Vergata  Rome Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lorenzo","family":"Arcuri","sequence":"additional","affiliation":[{"name":"Department of Odontostomatological and Maxillofacial Sciences Sapienza University of Rome  Rome Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2023,7,24]]},"reference":[{"key":"e_1_2_14_2_1","doi-asserted-by":"publisher","DOI":"10.1563\/aaid\u2010joi\u2010d\u201012\u201000117.1"},{"key":"e_1_2_14_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365\u20102842.2010.02113.x"},{"key":"e_1_2_14_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708\u20108208.2012.00482.x"},{"key":"e_1_2_14_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.14047"},{"key":"e_1_2_14_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600\u20100501.2009.01706.x"},{"key":"e_1_2_14_7_1","doi-asserted-by":"publisher","DOI":"10.11607\/ijp.4146"},{"key":"e_1_2_14_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12994"},{"key":"e_1_2_14_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpor.2019.06.001"},{"key":"e_1_2_14_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13162"},{"key":"e_1_2_14_11_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.5023"},{"key":"e_1_2_14_12_1","doi-asserted-by":"publisher","DOI":"10.11607\/ijp.4417"},{"key":"e_1_2_14_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2017.04.029"},{"key":"e_1_2_14_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13598"},{"key":"e_1_2_14_15_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12903\u2010017\u20100383\u20104"},{"key":"e_1_2_14_16_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600\u20100501.1995.060306.x"},{"key":"e_1_2_14_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpor.2011.02.004"},{"key":"e_1_2_14_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/s0022\u20103913(99)70229\u20105"},{"issue":"1","key":"e_1_2_14_19_1","first-page":"121","article-title":"Misfit of implant prostheses and its impact on clinical outcomes. Definition, assessment and a systematic review of the literature","volume":"10","author":"Katsoulis J.","year":"2017","journal-title":"European Journal of Oral Implantology"},{"key":"e_1_2_14_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpor.2019.07.010"},{"key":"e_1_2_14_21_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600\u20100501.1994.050104.x"},{"key":"e_1_2_14_22_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12903\u2010021\u201002005\u20100"},{"key":"e_1_2_14_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2016.01.006"},{"issue":"2","key":"e_1_2_14_24_1","first-page":"S133","article-title":"Optimal number of oral implants for fixed reconstructions: A review of the literature","volume":"7","author":"Mericske\u2010Stern R.","year":"2014","journal-title":"European Journal of Oral Implantology"},{"key":"e_1_2_14_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2019.01.003"},{"key":"e_1_2_14_26_1","doi-asserted-by":"publisher","DOI":"10.3390\/ijerph19074300"},{"issue":"2","key":"e_1_2_14_27_1","first-page":"194","article-title":"Comparisons of precision of fit between cast and CNC\u2010milled titanium implant frameworks for the edentulous mandible","volume":"16","author":"Ortorp A.","year":"2003","journal-title":"The International Journal of Prosthodontics"},{"key":"e_1_2_14_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2016.12.015"},{"key":"e_1_2_14_29_1","doi-asserted-by":"publisher","DOI":"10.2186\/jpr.jpr_d_21_00023"},{"key":"e_1_2_14_30_1","doi-asserted-by":"publisher","DOI":"10.11607\/ijp.5535"},{"key":"e_1_2_14_31_1","doi-asserted-by":"publisher","DOI":"10.2186\/jpr.jpor_2019_386"},{"key":"e_1_2_14_32_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13839"},{"key":"e_1_2_14_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2021.04.026"},{"key":"e_1_2_14_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2022.104072"},{"key":"e_1_2_14_35_1","doi-asserted-by":"publisher","DOI":"10.1111\/jerd.12710"},{"key":"e_1_2_14_36_1","doi-asserted-by":"publisher","DOI":"10.1563\/aaid\u2010joi\u2010d\u201013\u201000133"},{"issue":"4","key":"e_1_2_14_37_1","first-page":"325","article-title":"Different implant impression techniques for edentulous patients treated with CAD\/CAM complete\u2010arch prostheses: A randomised controlled trial reporting data at 3 year post\u2010loading","volume":"6","author":"Pozzi A.","year":"2013","journal-title":"European Journal of Oral Implantology"},{"key":"e_1_2_14_38_1","doi-asserted-by":"publisher","DOI":"10.14219\/jada.2013.45"},{"key":"e_1_2_14_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2020.03.005"},{"key":"e_1_2_14_40_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2021.05.019"},{"key":"e_1_2_14_41_1","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.2888"},{"issue":"1","key":"e_1_2_14_42_1","first-page":"101","article-title":"Accuracy of digital implant impressions with intraoral scanners. A systematic review","volume":"10","author":"Rutk\u016bnas V.","year":"2017","journal-title":"European Journal of Oral Implantology"},{"key":"e_1_2_14_43_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40729\u2010021\u201000352\u20109"},{"key":"e_1_2_14_44_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600\u20100501.2000.011s1156.x"},{"key":"e_1_2_14_45_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2018.01.005"},{"key":"e_1_2_14_46_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijsu.2014.07.013"},{"key":"e_1_2_14_47_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2022.03.033"}],"container-title":["Clinical Oral Implants Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/clr.14141","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,11]],"date-time":"2023-10-11T19:50:06Z","timestamp":1697053806000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/clr.14141"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,24]]},"references-count":46,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2023,10]]}},"alternative-id":["10.1111\/clr.14141"],"URL":"https:\/\/doi.org\/10.1111\/clr.14141","archive":["Portico"],"relation":{},"ISSN":["0905-7161","1600-0501"],"issn-type":[{"value":"0905-7161","type":"print"},{"value":"1600-0501","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7,24]]},"assertion":[{"value":"2023-02-11","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-07-13","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-07-24","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}