{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,16]],"date-time":"2026-01-16T12:13:41Z","timestamp":1768565621100,"version":"3.49.0"},"reference-count":27,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2023,11,10]],"date-time":"2023-11-10T00:00:00Z","timestamp":1699574400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clinical Oral Implants Res"],"published-print":{"date-parts":[[2024,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Aim<\/jats:title><jats:p>To introduce an objective method to evaluate the accuracy of implant position assessment in partially edentulous patients by comparing different techniques (conventional impression, intraoral scan, CBCT) to a reference 3D model obtained with an industrial scanner, the latter mimicking the clinical situation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and Methods<\/jats:title><jats:p>Twenty\u2010nine implants were placed in four human cadaver heads using a fully guided flapless protocol. Implant position was assessed using (a) a conventional impression, (b) an intraoral scan, and (c) CBCT and compared to an industrial scan. Three\u2010dimensional models of intraoral scan body and implant were registered to the arch models and the deviation at implant shoulder, apex, and the angle of deviation were compared to each other as well as to the reference model.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The three assessment techniques showed statistically significant deviations (<jats:italic>p<\/jats:italic>\u2009&lt;\u2009.01) from the industrial scan, for all measurements, with no difference between the techniques. The maximum deviation at the implant shoulder was 0.16\u2009mm. At the implant apex this increased to 0.38\u2009mm. The intraoral scan deviated significantly more than the CBCT (0.12\u2009mm, <jats:italic>p<\/jats:italic>\u2009&lt;\u2009.01) and the conventional impression (0.10\u2009mm, <jats:italic>p<\/jats:italic>\u2009=\u2009.02). The maximum implant angle deviation was 1.0\u00b0. The intraoral scan deviated more than the conventional impression (0.3\u00b0, <jats:italic>p<\/jats:italic>\u2009=\u2009.02).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>All assessment techniques deviated from the reference industrial scan, but the differences were relatively small. Intraoral scans were slightly less accurate than both conventional impressions and CBCT. Depending on the application, however, this inaccuracy may not be clinically relevant.<\/jats:p><\/jats:sec>","DOI":"10.1111\/clr.14206","type":"journal-article","created":{"date-parts":[[2023,11,6]],"date-time":"2023-11-06T06:29:35Z","timestamp":1699252175000},"page":"854-863","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Non\u2010invasive oral implant position assessment: An ex\u00a0vivo study using a <scp>3D<\/scp> industrial scan as the reference model to mimic the clinical situation"],"prefix":"10.1111","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6466-5261","authenticated-orcid":false,"given":"Mihai","family":"Tarce","sequence":"first","affiliation":[{"name":"Division of Periodontology &amp; Implant Dentistry, Faculty of Dentistry The University of Hong Kong  Hong Kong SAR China"},{"name":"Periodontology and Oral Microbiology, Department of Oral Health Sciences, Faculty of Medicine KU Leuven  Leuven Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1936-4683","authenticated-orcid":false,"given":"Kathrin","family":"Becker","sequence":"additional","affiliation":[{"name":"Charit\u00e9\u2010 Universit\u00e4tsmedizin Berlin, Corporate member of Freie Universit\u00e4t Berlin and Humboldt\u2010Universit\u00e4t zu Berlin Department of Orthodontics and Dentofacial Orthopedics  Berlin Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5555-2185","authenticated-orcid":false,"given":"Pierre","family":"Lahoud","sequence":"additional","affiliation":[{"name":"Periodontology and Oral Microbiology, Department of Oral Health Sciences, Faculty of Medicine KU Leuven  Leuven Belgium"},{"name":"OMFS\u2010IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine KU Leuven  Leuven Belgium"},{"name":"Department of Oral &amp; Maxillofacial Surgery University Hospitals Leuven  Leuven Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sohaib","family":"Shujaat","sequence":"additional","affiliation":[{"name":"OMFS\u2010IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine KU Leuven  Leuven Belgium"},{"name":"Department of Oral &amp; Maxillofacial Surgery University Hospitals Leuven  Leuven Belgium"},{"name":"King Abdullah International Medical Research Center, Department of Maxillofacial Surgery and Diagnostic Sciences, College of Dentistry, King Saud bin Abdulaziz University for Health Sciences Ministry of National Guard Health Affairs  Riyadh Kingdom of Saudi Arabia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3461-0363","authenticated-orcid":false,"given":"Reinhilde","family":"Jacobs","sequence":"additional","affiliation":[{"name":"OMFS\u2010IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine KU Leuven  Leuven Belgium"},{"name":"Department of Oral &amp; Maxillofacial Surgery University Hospitals Leuven  Leuven Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marc","family":"Quirynen","sequence":"additional","affiliation":[{"name":"Periodontology and Oral Microbiology, Department of Oral Health Sciences, Faculty of Medicine KU Leuven  Leuven Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2023,11,10]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1922\/EJPRD_01752Abduo21"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1155\/2021\/2673040"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13531"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1109\/34.121791"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/4292081"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.3290\/j.qi.a32244"},{"issue":"1","key":"e_1_2_10_8_1","first-page":"11","article-title":"Accuracy of complete\u2010 and partial\u2010arch impressions of actual intraoral scanning systems in\u00a0vitro","volume":"22","author":"Ender A.","year":"2019","journal-title":"International Journal of Computerized Dentistry"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.5624\/isd.20210076"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13273"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.4317\/jced.57025"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600\u20100501.2012.02441.x"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12903\u2010018\u20100523\u20105"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.3390\/ijerph18031020"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2017.10.029"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40510\u2010020\u201000337\u20101"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2017.12.006"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12567"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13345"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13951"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00784\u2010021\u201004157\u20103"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajodo.2017.09.022"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2018.01.005"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600\u20100501.2012.02552.x"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/jcpe.13183"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12214"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13309"},{"issue":"2","key":"e_1_2_10_28_1","first-page":"157","article-title":"Accuracy of full\u2010arch digital implant impressions taken using intraoral scanners and related variables: A systematic review","volume":"14","author":"Zhang Y.\u2010J.","year":"2021","journal-title":"International Journal of Oral implantology (Berlin, Germany)"}],"container-title":["Clinical Oral Implants Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/clr.14206","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,8]],"date-time":"2024-08-08T06:12:29Z","timestamp":1723097549000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/clr.14206"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,10]]},"references-count":27,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2024,8]]}},"alternative-id":["10.1111\/clr.14206"],"URL":"https:\/\/doi.org\/10.1111\/clr.14206","archive":["Portico"],"relation":{},"ISSN":["0905-7161","1600-0501"],"issn-type":[{"value":"0905-7161","type":"print"},{"value":"1600-0501","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,10]]},"assertion":[{"value":"2023-07-31","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-11-01","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-11-10","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}