{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T00:47:02Z","timestamp":1787014022634,"version":"build-2736575974"},"reference-count":39,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2025,1,31]],"date-time":"2025-01-31T00:00:00Z","timestamp":1738281600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clinical Oral Implants Res"],"published-print":{"date-parts":[[2025,5]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>To evaluate the trueness of maxillary and mandibular full\u2010arch implant digital impressions with and without additional reference objects.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Material and Methods<\/jats:title>\n                    <jats:p>\n                      Seventeen maxillary and 6 mandibular arches with four implants were randomly divided into a group with additional reference objects (wRO group,\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200912) and without them (woRO group,\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200911) and scanned with an intraoral scanner (IOS). For each jaw, the control model (CM) data was obtained to evaluate the deviations in the scan body positions in the wRO and woRO groups. CM and IOS data sets were imported into metrology software for distance and angle measurements between scan body pairs 1\u20132, 1\u20133, and 1\u20134. Unsigned values of distance and angle data differences between CM and IOS groups were used for further analysis.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The highest statistically significant (\n                      <jats:italic>p\u2009&lt;\u20090.05<\/jats:italic>\n                      ) differences between distance and angulation measurements of the maxilla and mandible were observed in the 1\u20134 scan body pair group (136\u2009\u00b1\u200995\u2009\u03bcm, 0.95\u00b0\u2009\u00b1\u20090.79\u00b0; 362\u2009\u00b1\u2009233\u2009\u03bcm, 2.22\u00b0\u2009\u00b1\u20092.11\u00b0, respectively). Distance deviations of the mandible were higher in all scan body pair groups. The woRO group had higher distance and angulation unsigned trueness values than in the wRO group, especially in the 1\u20134 scan body pair (224\u2009\u00b1\u2009183\u2009\u03bcm, 1.77\u00b0\u2009\u00b1\u20091.76\u00b0;169\u2009\u00b1\u2009162\u2009\u03bcm, and 0.83\u00b0\u2009\u00b1\u20090.57\u00b0, respectively).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>IOS for the full\u2010arch cases had statistically and clinically significant distance and angle deviations. Higher deviations were observed in the single mandibular scan body pair. The tendency of diminished distance and angular deviations with the utilization of the additional reference objects was observed, though these differences were not statistically significant.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/clr.14411","type":"journal-article","created":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:08:56Z","timestamp":1738368536000},"page":"640-649","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Full\u2010Arch Digital Implant Impression Trueness: An in Vivo Study"],"prefix":"10.1111","volume":"36","author":[{"given":"Vygandas","family":"Rutk\u016bnas","sequence":"first","affiliation":[{"name":"Department of Prosthodontics, Institute of Odontology, Faculty of Medicine Vilnius University  Vilnius Lithuania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Kule\u0161","sequence":"additional","affiliation":[{"name":"Department of Periodontology, Institute of Odontology, Faculty of Medicine Vilnius University  Vilnius Lithuania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2854-1135","authenticated-orcid":false,"given":"Marta","family":"Revilla\u2010Le\u00f3n","sequence":"additional","affiliation":[{"name":"Department of Restorative Dentistry, School of Dental Medicine University of Washington  Seattle Washington USA"},{"name":"Kois Center  Seattle Washington USA"},{"name":"Department of Prosthodontics, School of Dental Medicine Tufts University  Boston Massachusetts USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mykolas","family":"Akulauskas","sequence":"additional","affiliation":[{"name":"Biomedical Engineering Institute Kaunas University of Technology  Kaunas Lithuania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liudas","family":"Au\u0161kalnis","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Institute of Odontology, Faculty of Medicine Vilnius University  Vilnius Lithuania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ieva","family":"Gendvilien\u0117","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Institute of Odontology, Faculty of Medicine Vilnius University  Vilnius Lithuania"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,1,31]]},"reference":[{"key":"e_1_2_11_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.12764"},{"key":"e_1_2_11_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12994"},{"key":"e_1_2_11_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2013.07.010"},{"key":"e_1_2_11_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2020.09.008"},{"key":"e_1_2_11_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpor.2019.04.002"},{"key":"e_1_2_11_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.12362"},{"key":"e_1_2_11_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajodo.2013.04.017"},{"key":"e_1_2_11_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2022.104095"},{"key":"e_1_2_11_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.12457"},{"issue":"4","key":"e_1_2_11_11_1","first-page":"550","article-title":"Accuracy of Computerized and Conventional Impression\u2010Making Procedures for Multiple Straight and Tilted Dental Implants","volume":"13","author":"Gintaute A.","year":"2018","journal-title":"International Journal of Esthetic Dentistry"},{"key":"e_1_2_11_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2022.104307"},{"key":"e_1_2_11_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13598"},{"key":"e_1_2_11_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2018.09.017"},{"issue":"3","key":"e_1_2_11_15_1","first-page":"270","article-title":"Failures and Complications in 391 Consecutively Inserted Fixed Prostheses Supported by Br\u00e5nemark Implants in Edentulous Jaws: A Study of Treatment From the Time of Prosthesis Placement to the First Annual Checkup","volume":"6","author":"Jemt T.","year":"1991","journal-title":"International Journal of Oral and Maxillofacial Implants"},{"key":"e_1_2_11_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2022.104266"},{"key":"e_1_2_11_17_1","first-page":"121","article-title":"Misfit of Implant Prostheses and Its Impact on Clinical Outcomes. Definition, Assessment and a Systematic Review of the Literature","volume":"10","author":"Katsoulis J.","year":"2017","journal-title":"European Journal of Oral Implantology"},{"issue":"1","key":"e_1_2_11_18_1","first-page":"17","article-title":"Influence of Intraoral Conditions on the Accuracy of Full\u2010Arch Scans by Cerec Primescan AC: An In\u00a0Vitro and In\u00a0Vivo Comparison","volume":"25","author":"Keul C.","year":"2022","journal-title":"International Journal of Computerized Dentistry"},{"key":"e_1_2_11_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2018.10.018"},{"key":"e_1_2_11_20_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0163107"},{"key":"e_1_2_11_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2019.01.003"},{"key":"e_1_2_11_22_1","doi-asserted-by":"publisher","DOI":"10.1922\/EJPRD_1962Moslemion10"},{"key":"e_1_2_11_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2021.05.012"},{"key":"e_1_2_11_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.12968"},{"key":"e_1_2_11_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13968"},{"key":"e_1_2_11_26_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13772"},{"key":"e_1_2_11_27_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.12567"},{"key":"e_1_2_11_28_1","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.13211"},{"key":"e_1_2_11_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2022.104072"},{"key":"e_1_2_11_30_1","doi-asserted-by":"publisher","DOI":"10.1111\/jerd.12993"},{"key":"e_1_2_11_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2022.104267"},{"issue":"1","key":"e_1_2_11_32_1","first-page":"101","article-title":"Accuracy of Digital Implant Impressions With Intraoral Scanners. A Systematic Review","volume":"10","author":"Rutk\u016bnas V.","year":"2017","journal-title":"European Journal of Oral Implantology"},{"key":"e_1_2_11_33_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.13844"},{"key":"e_1_2_11_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2021.09.032"},{"key":"e_1_2_11_35_1","doi-asserted-by":"publisher","DOI":"10.1922\/EJPRD_2481Rutkunas12"},{"key":"e_1_2_11_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2013.08.015"},{"key":"e_1_2_11_37_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.12885"},{"key":"e_1_2_11_38_1","doi-asserted-by":"publisher","DOI":"10.3390\/prosthesis4030029"},{"key":"e_1_2_11_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2022.02.016"},{"key":"e_1_2_11_40_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2021.09.035"}],"container-title":["Clinical Oral Implants Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/clr.14411","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,31]],"date-time":"2025-05-31T00:22:09Z","timestamp":1748650929000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/clr.14411"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,31]]},"references-count":39,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025,5]]}},"alternative-id":["10.1111\/clr.14411"],"URL":"https:\/\/doi.org\/10.1111\/clr.14411","archive":["Portico"],"relation":{},"ISSN":["0905-7161","1600-0501"],"issn-type":[{"value":"0905-7161","type":"print"},{"value":"1600-0501","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,31]]},"assertion":[{"value":"2024-02-22","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-19","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-31","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}