{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T12:14:55Z","timestamp":1790424895487,"version":"4.1.0"},"reference-count":26,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T00:00:00Z","timestamp":1742947200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82401189"],"award-info":[{"award-number":["82401189"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100018542","name":"Natural Science Foundation of Sichuan Province","doi-asserted-by":"publisher","award":["2025ZNSFSC0748"],"award-info":[{"award-number":["2025ZNSFSC0748"]}],"id":[{"id":"10.13039\/501100018542","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clinical Oral Implants Res"],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>To assess the reproduction accuracy of a surgical guide during both the manufacturing phase (from designed files to manufactured surgical guides) and the application phase (from manufactured surgical guides to post\u2010plasma sterilization) across four three\u2010dimensional (3D) printing technologies.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>Twenty\u2010four surgical guides were designed and categorized into four groups (six surgical guides per group) based on the printing technology used: stereolithography apparatus (SLA), digital light processing (DLP), laser cladding deposition (LCD), and selective laser melting (SLM). The surgical guide files were collected in three conditions: design, post\u2010printing, and post\u2010plasma sterilization. The integrated precision, regional precision, and implant precision of the surgical guides were evaluated by measuring (1) T\u2010vertex marker distance and angle, (2) surgical guide deformation after superimposition, and (3) implant 3D displacement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      SLA printers exhibited the lowest reproduction accuracy and implant precision during the manufacturing phase (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001) and demonstrated the lowest implant precision during the application phase. In contrast, SLM printers displayed the highest reproduction accuracy and implant precision across both phases (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). LCD printers showed slightly lower reproduction accuracy and implant precision than SLM during both the manufacturing and application phases.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>SLM printers provide superior precision for implant surgery. Their use is recommended for printing surgical guides due to their high reproduction accuracy and implant precision during the manufacturing and application phases. In cases where SLM technology is unavailable, LCD printers offer a reliable alternative.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/clr.14437","type":"journal-article","created":{"date-parts":[[2025,3,29]],"date-time":"2025-03-29T04:16:47Z","timestamp":1743221807000},"page":"771-784","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Manufacturing and Application Precision Changes in Three\u2010Dimensional Printed Surgical Guides for Dental Implants: An In\u00a0Vitro Study"],"prefix":"10.1111","volume":"36","author":[{"given":"Mengxi","family":"Yang","sequence":"first","affiliation":[{"name":"Department of Implant Dentistry, West China Hospital of Stomatology Sichuan University  Chengdu China"},{"name":"State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University  Chengdu China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruikun","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Implant Dentistry, West China Hospital of Stomatology Sichuan University  Chengdu China"},{"name":"State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University  Chengdu China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xueyuan","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology The General Hospital of Western Theater Command  Chengdu China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shibo","family":"Liu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University  Chengdu China"},{"name":"Orthognathic and TMJ Surgery, West China Hospital of Stomatology Sichuan University  Chengdu China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Songhang","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Implant Dentistry, West China Hospital of Stomatology Sichuan University  Chengdu China"},{"name":"State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University  Chengdu China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,3,26]]},"reference":[{"key":"e_1_2_11_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bprint.2024.e00356"},{"key":"e_1_2_11_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2018.11.010"},{"key":"e_1_2_11_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708\u20108208.2010.00275.x"},{"key":"e_1_2_11_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.12836"},{"key":"e_1_2_11_6_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12903\u2010022\u201002057\u2010w"},{"key":"e_1_2_11_7_1","doi-asserted-by":"publisher","DOI":"10.3390\/mi14010057"},{"key":"e_1_2_11_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.14009"},{"key":"e_1_2_11_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.14158"},{"key":"e_1_2_11_10_1","doi-asserted-by":"publisher","DOI":"10.3390\/ma16103847"},{"key":"e_1_2_11_11_1","first-page":"92","article-title":"Computer Technology Applications in Surgical Implant Dentistry: A Systematic Review","volume":"24","author":"Jung R. E.","year":"2009","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_11_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jds.2021.09.030"},{"key":"e_1_2_11_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2024.104936"},{"key":"e_1_2_11_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.13350"},{"key":"e_1_2_11_15_1","doi-asserted-by":"publisher","DOI":"10.3390\/polym15122692"},{"key":"e_1_2_11_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00784\u2010021\u201003999\u20101"},{"key":"e_1_2_11_17_1","doi-asserted-by":"publisher","DOI":"10.3390\/pharmaceutics13111837"},{"key":"e_1_2_11_18_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00784-016-1904-2"},{"key":"e_1_2_11_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/cid.13354"},{"key":"e_1_2_11_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/clr.14198"},{"key":"e_1_2_11_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2021.103909"},{"key":"e_1_2_11_22_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm9051506"},{"key":"e_1_2_11_23_1","doi-asserted-by":"publisher","DOI":"10.1177\/00220345241253794"},{"key":"e_1_2_11_24_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm10214894"},{"key":"e_1_2_11_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jot.2024.02.004"},{"key":"e_1_2_11_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2024.10.031"},{"key":"e_1_2_11_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2022.11.018"}],"container-title":["Clinical Oral Implants Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/clr.14437","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,28]],"date-time":"2025-11-28T20:47:47Z","timestamp":1764362867000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/clr.14437"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,26]]},"references-count":26,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,6]]}},"alternative-id":["10.1111\/clr.14437"],"URL":"https:\/\/doi.org\/10.1111\/clr.14437","archive":["Portico"],"relation":{},"ISSN":["0905-7161","1600-0501"],"issn-type":[{"value":"0905-7161","type":"print"},{"value":"1600-0501","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,26]]},"assertion":[{"value":"2024-10-15","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-03-11","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-03-26","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}