{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T09:48:09Z","timestamp":1784800089779,"version":"3.55.0"},"reference-count":18,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2017,5,29]],"date-time":"2017-05-29T00:00:00Z","timestamp":1496016000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clinical Otolaryngology"],"published-print":{"date-parts":[[2018,2]]},"abstract":"<jats:sec><jats:title>Objectives<\/jats:title><jats:p>To define fitting ranges for nine bone conduction devices (<jats:styled-content style=\"fixed-case\">BCD<\/jats:styled-content>s) over different frequencies based on the device's maximum power output (<jats:styled-content style=\"fixed-case\">MPO<\/jats:styled-content>) and to validate the assessment of <jats:styled-content style=\"fixed-case\">MPO<\/jats:styled-content> of BCDs in the ear canal.<\/jats:p><\/jats:sec><jats:sec><jats:title>Background<\/jats:title><jats:p>Maximum power output (MPO) is an important characteristic when fitting BCDs. It is the highest output level a device can deliver and is one of the major determinants of a device's fitting range. A skull simulator can be used to verify <jats:styled-content style=\"fixed-case\">MPO<\/jats:styled-content> of percutaneous BCDs. No such simulator is available for active and passive transcutaneous devices.<\/jats:p><\/jats:sec><jats:sec><jats:title>Design<\/jats:title><jats:p>The <jats:styled-content style=\"fixed-case\">MPO<\/jats:styled-content> of nine different <jats:styled-content style=\"fixed-case\">BCD<\/jats:styled-content>s was assessed either by real\u2010ear measurements and\/or with skull simulator measurements.<\/jats:p><\/jats:sec><jats:sec><jats:title>Main outcome measures<\/jats:title><jats:p>MPO and cross\u2010validation of the methods using the Bland\u2013Altman method.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Percutaneous BCDs have higher <jats:styled-content style=\"fixed-case\">MPO<\/jats:styled-content> levels compared to active and passive transcutaneous devices. This results in a wide dynamic range of hearing for percutaneous devices. Moreover, the assessment of <jats:styled-content style=\"fixed-case\">MPO<\/jats:styled-content> by real\u2010ear measurements was validated.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Based on <jats:styled-content style=\"fixed-case\">MPO<\/jats:styled-content> data, fitting ranges were defined for nine BCDs over seven frequencies.<\/jats:p><\/jats:sec>","DOI":"10.1111\/coa.12901","type":"journal-article","created":{"date-parts":[[2017,5,9]],"date-time":"2017-05-09T07:16:41Z","timestamp":1494314201000},"page":"68-75","source":"Crossref","is-referenced-by-count":28,"title":["Determining fitting ranges of various bone conduction hearing aids"],"prefix":"10.1111","volume":"43","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5548-8168","authenticated-orcid":false,"given":"D.C.P.B.M.","family":"van Barneveld","sequence":"first","affiliation":[{"name":"Department of Otolaryngology and Head and Neck Surgery Donders Institute for Brain, Cognition and Behaviour Radboud University Nijmegen Medical Centre Nijmegen The Netherlands"},{"name":"Department of ENT\/Audiology School for Mental Health and Neuroscience (MHENS) Maastricht University Medical Center Maastricht The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H.J.W.","family":"Kok","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology and Head and Neck Surgery Donders Institute for Brain, Cognition and Behaviour Radboud University Nijmegen Medical Centre Nijmegen The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.F.P.","family":"Noten","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology and Head and Neck Surgery Donders Institute for Brain, Cognition and Behaviour Radboud University Nijmegen Medical Centre Nijmegen The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.J.","family":"Bosman","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology and Head and Neck Surgery Donders Institute for Brain, Cognition and Behaviour Radboud University Nijmegen Medical Centre Nijmegen The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.F.M.","family":"Snik","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology and Head and Neck Surgery Donders Institute for Brain, Cognition and Behaviour Radboud University Nijmegen Medical Centre Nijmegen The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2017,5,29]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.2147\/MDER.S39691"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003446-199702000-00004"},{"key":"e_1_2_8_4_1","doi-asserted-by":"crossref","first-page":"1126","DOI":"10.1097\/MAO.0000000000000347","article-title":"An experimental objective method to determine maximum output and dynamic range of an active bone conduction implant: the Bonebridge","volume":"35","author":"Mertens G","year":"2014","journal-title":"Otol Neurotol"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00106-015-0087-5"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000000258"},{"key":"e_1_2_8_7_1","first-page":"379","article-title":"Sound pressure in the external auditory canal during bone\u2010conduction testing","volume":"5","author":"Fagelson M","year":"1994","journal-title":"J Am Acad Audiol"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.3766\/jaaa.15.3.7"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.412225"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003446-198902000-00010"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003446-199808000-00001"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1177\/019459989010200407"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.3109\/01050398409076252"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e3182868608"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.3109\/00206097509071720"},{"key":"e_1_2_8_17_1","first-page":"1","article-title":"An easy method for calculation the articulation index","volume":"43","author":"Mueller HG","year":"1990","journal-title":"Hearing Journal"},{"key":"e_1_2_8_18_1","first-page":"105","article-title":"Are today's implantable devices better than conventional solutions for patients with conductive and mixed hearing loss?","volume":"23","author":"Snik AFM","year":"2014","journal-title":"ENT and Audiology news"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1080\/14992020600673189"}],"container-title":["Clinical Otolaryngology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fcoa.12901","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/coa.12901","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T18:42:13Z","timestamp":1695494533000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/coa.12901"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,5,29]]},"references-count":18,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,2]]}},"alternative-id":["10.1111\/coa.12901"],"URL":"https:\/\/doi.org\/10.1111\/coa.12901","archive":["Portico"],"relation":{},"ISSN":["1749-4478","1749-4486"],"issn-type":[{"value":"1749-4478","type":"print"},{"value":"1749-4486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,5,29]]}}}