{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T12:57:00Z","timestamp":1760101020264,"version":"3.37.3"},"reference-count":29,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2017,11,28]],"date-time":"2017-11-28T00:00:00Z","timestamp":1511827200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"Med-El research"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clinical Otolaryngology"],"published-print":{"date-parts":[[2018,4]]},"abstract":"<jats:sec><jats:title>Hypothesis<\/jats:title><jats:p>The vibration of the floating mass transducer (<jats:styled-content style=\"fixed-case\">FMT<\/jats:styled-content>) of a single active middle\u2010ear implant (<jats:styled-content style=\"fixed-case\">AMEI<\/jats:styled-content>) is distinctly influenced by the properties of the material coupled to its back side.<\/jats:p><\/jats:sec><jats:sec><jats:title>Background<\/jats:title><jats:p>In round window vibroplasty, the <jats:styled-content style=\"fixed-case\">FMT<\/jats:styled-content> needs to be padded against the surrounding bone opposite from the round window membrane. This represents one factor influencing its performance as a round window driver. Therefore, we examined the effects of different materials linked to the back side of an <jats:styled-content style=\"fixed-case\">FMT<\/jats:styled-content> on its vibration range.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The back side of an <jats:styled-content style=\"fixed-case\">FMT<\/jats:styled-content> was glued to a silicone cylinder 1.0 mm in diameter and 1.0 mm \u2013 1.5 mm in length and of 40A, 50A or 70A Shore hardness; to cartilage of equivalent size; or to a round window soft coupler (<jats:styled-content style=\"fixed-case\">RWSC<\/jats:styled-content>), all firmly fixed on a steel plate. The vibrations were determined by a laser Doppler vibrometer (<jats:styled-content style=\"fixed-case\">LDV<\/jats:styled-content>) measuring the velocity of the centre point on the front side of the <jats:styled-content style=\"fixed-case\">FMT<\/jats:styled-content>.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The materials on the back side of the <jats:styled-content style=\"fixed-case\">FMT<\/jats:styled-content> significantly influenced the vibration range of the <jats:styled-content style=\"fixed-case\">FMT<\/jats:styled-content>. The <jats:styled-content style=\"fixed-case\">RWSC<\/jats:styled-content> and silicone of 40A Shore hardness allowed for the highest detected velocities, while cartilage led to a distinct reduction similarly to 70A silicone.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The coupling on the back side of an <jats:styled-content style=\"fixed-case\">FMT<\/jats:styled-content> distinctly affects its vibration range. In this regard, the <jats:styled-content style=\"fixed-case\">RWSC<\/jats:styled-content> and silicone of 40A Shore hardness yield the least impairment of vibration. Thus, the <jats:styled-content style=\"fixed-case\">RWSC<\/jats:styled-content> may be a feasible option in round window vibroplasty when additionally connected to the <jats:styled-content style=\"fixed-case\">FMT<\/jats:styled-content> opposite from the round window membrane.<\/jats:p><\/jats:sec>","DOI":"10.1111\/coa.13017","type":"journal-article","created":{"date-parts":[[2017,10,20]],"date-time":"2017-10-20T23:02:38Z","timestamp":1508540558000},"page":"538-543","source":"Crossref","is-referenced-by-count":2,"title":["Influence of backside loading on the floating mass transducer: An in vitro experimental study"],"prefix":"10.1111","volume":"43","author":[{"given":"A.\u2010O.","family":"Gostian","sequence":"first","affiliation":[{"name":"Medical Faculty Department of Otorhinolaryngology, Head and Neck Surgery University of Cologne Cologne Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9658-1502","authenticated-orcid":false,"given":"M.S.","family":"Otte","sequence":"additional","affiliation":[{"name":"Medical Faculty Department of Otorhinolaryngology, Head and Neck Surgery University of Cologne Cologne Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"Pazen","sequence":"additional","affiliation":[{"name":"Medical Faculty Department of Otorhinolaryngology, Head and Neck Surgery University of Cologne Cologne Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Ortmann","sequence":"additional","affiliation":[{"name":"Jean Uhrmacher\u2010Institute for Clinical ENT\u2010Research University of Cologne Cologne Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4580-8383","authenticated-orcid":false,"given":"D.","family":"Schwarz","sequence":"additional","affiliation":[{"name":"Medical Faculty Department of Otorhinolaryngology, Head and Neck Surgery University of Cologne Cologne Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.B.","family":"H\u00fcttenbrink","sequence":"additional","affiliation":[{"name":"Medical Faculty Department of Otorhinolaryngology, Head and Neck Surgery University of Cologne Cologne Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"Beutner","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology, Head and Neck Surgery University Medical Center G\u00f6ttingen G\u00f6ttingen Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2017,11,28]]},"reference":[{"key":"e_1_2_9_2_1","first-page":"38","article-title":"The vibrant soundbridge for conductive and mixed hearing losses: European multicenter study results","volume":"69","author":"Baumgartner WD","year":"2010","journal-title":"Adv Otorhinolaryngol"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e318180a495"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.3109\/00016489.2011.649492"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e3182487f98"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e31829b57c2"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00106-007-1540-x"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e3182990d2b"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2009.12.019"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e318218d180"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e318185fad8"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e3181c34ee0"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.3109\/00016489.2012.684701"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1159\/000095282"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1177\/0003489414534013"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1080\/14992020600840903"},{"key":"e_1_2_9_17_1","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1097\/MAO.0000000000000655","article-title":"Impact of coupling techniques of an active middle ear device to the round window membrane for the backward stimulation of the cochlea","volume":"36","author":"Gostian AO","year":"2015","journal-title":"Otol Neurotol"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2012.12.010"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e3181c0ea9f"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e3181e8fc21"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2014.04.001"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000001028"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-016-3997-2"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/lary.25040"},{"key":"e_1_2_9_25_1","first-page":"443","article-title":"Transfer\u2010function measurement with sweeps","volume":"49","author":"Muller S","year":"2001","journal-title":"J Audio Eng Soc"},{"volume-title":"Discovering Statistics using IBM SPSS Statistics","year":"2013","author":"Field A","key":"e_1_2_9_26_1"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e318206fda1"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1159\/000333807"},{"key":"e_1_2_9_29_1","unstructured":"GmbH V.M.\u2010E.H.T. VIBRANT SOUNDBRIDGE\u00ae \u2010Information for Surgeons In Information for Surgeons (VORP 503) p.29. VIBRANT MED\u2010EL | Hearing Technology GmbH F\u00fcrstenweg 77 | 6020 Innsbruck Austria |vibrant@medel.com Innsbruck Austria"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000000332"}],"container-title":["Clinical Otolaryngology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fcoa.13017","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/coa.13017","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,16]],"date-time":"2023-09-16T23:25:58Z","timestamp":1694906758000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/coa.13017"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11,28]]},"references-count":29,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018,4]]}},"alternative-id":["10.1111\/coa.13017"],"URL":"https:\/\/doi.org\/10.1111\/coa.13017","archive":["Portico"],"relation":{},"ISSN":["1749-4478","1749-4486"],"issn-type":[{"type":"print","value":"1749-4478"},{"type":"electronic","value":"1749-4486"}],"subject":[],"published":{"date-parts":[[2017,11,28]]}}}