{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T15:19:03Z","timestamp":1787671143769,"version":"build-2736575974"},"reference-count":18,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2016,1,27]],"date-time":"2016-01-27T00:00:00Z","timestamp":1453852800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clin Physio Funct Imaging"],"published-print":{"date-parts":[[2017,11]]},"abstract":"<jats:title>Summary<\/jats:title><jats:p>Recently, research has validated the use of Polar<jats:sup>\u00ae<\/jats:sup> heart rate monitors as a tool to index heart rate variability (<jats:styled-content style=\"fixed-case\">HRV<\/jats:styled-content>). In the current investigation, we sought to evaluate the test\u2013retest reliability of both time and frequency domain measures of <jats:styled-content style=\"fixed-case\">HRV<\/jats:styled-content> using the Polar<jats:sup>\u00ae<\/jats:sup> <jats:styled-content style=\"fixed-case\">RS<\/jats:styled-content>800<jats:styled-content style=\"fixed-case\">CX<\/jats:styled-content><jats:sup>\u2122<\/jats:sup>. Continuous <jats:styled-content style=\"fixed-case\">HRV<\/jats:styled-content> data were collected as 60 nominally healthy adults underwent a resting and orthostatic stress test. We evaluated reproducibility by means of the interclass correlation coefficient for absolute agreement and consistency, and the standard error of measurement. We found moderate reliable 2\u2010week test\u2013retest reliability of <jats:styled-content style=\"fixed-case\">HRV<\/jats:styled-content> using the Polar<jats:sup>\u00ae<\/jats:sup> <jats:styled-content style=\"fixed-case\">RS<\/jats:styled-content>800<jats:styled-content style=\"fixed-case\">CX<\/jats:styled-content><jats:sup>\u2122<\/jats:sup>, results that are in line with previous studies that have validated the stability of <jats:styled-content style=\"fixed-case\">HRV<\/jats:styled-content> using other methods of measurement (e.g. electrocardiogram). Additionally, when examining different methods of spectral density estimation, we found that using the auto\u2010regressive transformation method provides the most stable indices of <jats:styled-content style=\"fixed-case\">HRV<\/jats:styled-content>. Taken together, our results suggest that the Polar<jats:sup>\u00ae<\/jats:sup> <jats:styled-content style=\"fixed-case\">RS<\/jats:styled-content>800<jats:styled-content style=\"fixed-case\">CX<\/jats:styled-content><jats:sup>\u2122<\/jats:sup> is not only a valid method to record <jats:styled-content style=\"fixed-case\">HRV<\/jats:styled-content>, but also a reliable one, particularly when using the auto\u2010regressive transformation method.<\/jats:p>","DOI":"10.1111\/cpf.12321","type":"journal-article","created":{"date-parts":[[2016,1,27]],"date-time":"2016-01-27T06:19:16Z","timestamp":1453875556000},"page":"776-781","source":"Crossref","is-referenced-by-count":62,"title":["Two\u2010week test\u2013retest reliability of the <scp>P<\/scp>olar<sup>\u00ae<\/sup><scp>RS<\/scp>800<scp>CX<\/scp><sup>\u2122<\/sup> to\u00a0record heart rate variability"],"prefix":"10.1111","volume":"37","author":[{"given":"DeWayne P.","family":"Williams","sequence":"first","affiliation":[{"name":"Department of Psychology The Ohio State University Columbus OH USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc N.","family":"Jarczok","sequence":"additional","affiliation":[{"name":"Mannheim Institute of Public Health, Social and Preventive Medicine Mannheim Medical Faculty Heidelberg University Mannheim Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert J.","family":"Ellis","sequence":"additional","affiliation":[{"name":"School of Computing National University of Singapore Singapore City Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas K.","family":"Hillecke","sequence":"additional","affiliation":[{"name":"School of Therapeutic Sciences SRH University of Applied Sciences Heidelberg Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julian F.","family":"Thayer","sequence":"additional","affiliation":[{"name":"Department of Psychology The Ohio State University Columbus OH USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julian","family":"Koenig","sequence":"additional","affiliation":[{"name":"Department of Psychology The Ohio State University Columbus OH USA"},{"name":"Section for Translational Psychobiology in Child and Adolescent Psychiatry Department of Child and Adolescent Psychiatry Centre for Psychosocial Medicine University of Heidelberg Heidelberg Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2016,1,27]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1998.tb00159.x"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/cpf.12203"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1469-8986.1997.tb02140.x"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2004.12.018"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1590\/S0100-879X2010007500101"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1249\/01.mss.0000218135.79476.9c"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0188-4409(00)00255-1"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1109\/PROC.1981.12184"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-2004-817878"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jelectrocard.2005.08.001"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/0008-6363(96)00086-7"},{"key":"e_1_2_7_13_1","first-page":"708","volume-title":"Principles of Psychophysiology: Physical, Social, and Inferential Elements","author":"Porges S","year":"1990"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2004.09.013"},{"key":"e_1_2_7_15_1","volume-title":"Kubios HRV Version 2.0 User's Guide","author":"Tarvainen MP","year":"2008"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-540-89208-3_243"},{"key":"e_1_2_7_17_1","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1093\/oxfordjournals.eurheartj.a014868","article-title":"Heart rate variability: standards of measurement, physiological interpretation, and clinical use","volume":"17","author":"Task Force of the European Society of Cardiology, the North American Society of Pacing and Electrophysiology","year":"1996","journal-title":"Eur Heart J"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1109\/MEMB.2002.1032638"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1519\/15184.1"}],"container-title":["Clinical Physiology and Functional Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fcpf.12321","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fcpf.12321","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/cpf.12321","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,29]],"date-time":"2023-09-29T14:12:26Z","timestamp":1695996746000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/cpf.12321"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,1,27]]},"references-count":18,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2017,11]]}},"alternative-id":["10.1111\/cpf.12321"],"URL":"https:\/\/doi.org\/10.1111\/cpf.12321","archive":["Portico"],"relation":{},"ISSN":["1475-0961","1475-097X"],"issn-type":[{"value":"1475-0961","type":"print"},{"value":"1475-097X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,1,27]]}}}