{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T06:25:13Z","timestamp":1781245513265,"version":"3.54.1"},"reference-count":42,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2022,5,19]],"date-time":"2022-05-19T00:00:00Z","timestamp":1652918400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clin Physio Funct Imaging"],"published-print":{"date-parts":[[2022,7]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The heart rate variability threshold (HRVT) is a clinical parameter used to gain insight into autonomic balance. Prior validation of the HRVT has been with cycle ergometry, with no studies examining the viability of treadmill exercise. The purpose of this study was to examine the reliability of the HRVT during treadmill exercise, and to compare the HRVT to the ventilatory threshold (VT). Ten healthy, college\u2010aged males completed two maximal graded exercise tests on a treadmill. A Polar RS800CX watch was used for heart rate and HRVT data. The HRVT was determined from three HRV variables including the root mean square of successive differences of continuous R\u2212R intervals (RMSSD), the standard deviation of normal R\u2212R intervals (SDNN)\u00a0and the standard deviation of instantaneous beat intervals (SD1). A metabolic cart was utilized to determine the VT. Results showed no difference between the HRVT (2.4\u2009\u00b1\u20090.6 and 2.2\u2009\u00b1\u20090.3 for RMSSD, 2.8\u2009\u00b1\u20090.5 and 2.7\u2009\u00b1\u20090.5 for SDNN\u00a0and 2.4\u2009\u00b1\u20090.6 and 2.3\u2009\u00b1\u20090.6 for SD1) or the VT (3.0\u2009\u00b1\u20090.3 and 3.1\u2009\u00b1\u20090.3) between trials. When compared to the VT, averaged HRVT values for RMSSD (2.3\u2009\u00b1\u20090.3) and SD1 (2.3\u2009\u00b1\u20090.5) were lower than averaged VT (2.8\u2009\u00b1\u20090.4, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.05). The averaged HRVT from SDNN (2.8\u2009\u00b1\u20090.5) did not differ from the VT. These results suggest that treadmill is a viable mode for HRVT determination, and that HRVT determined by SDNN may be a better comparison to the VT.<\/jats:p>","DOI":"10.1111\/cpf.12760","type":"journal-article","created":{"date-parts":[[2022,5,7]],"date-time":"2022-05-07T07:09:58Z","timestamp":1651907398000},"page":"292-299","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Reliability of the heart rate variability threshold during treadmill exercise"],"prefix":"10.1111","volume":"42","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5930-4872","authenticated-orcid":false,"given":"Trent A.","family":"Hargens","sequence":"first","affiliation":[{"name":"Department of Kinesiology, Human Performance Laboratory James Madison University  Harrisonburg Virginia USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shane","family":"Chambers","sequence":"additional","affiliation":[{"name":"Department of Kinesiology, Human Performance Laboratory James Madison University  Harrisonburg Virginia USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicholas D.","family":"Luden","sequence":"additional","affiliation":[{"name":"Department of Kinesiology, Human Performance Laboratory James Madison University  Harrisonburg Virginia USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher J.","family":"Womack","sequence":"additional","affiliation":[{"name":"Department of Kinesiology, Human Performance Laboratory James Madison University  Harrisonburg Virginia USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2022,5,19]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0838.2004.00424.x"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s004210000302"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/cpf.12203"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1986.60.6.2020"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0035-1554642"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/mus.25573"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1590\/1414-431x20143713"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1590\/1414-431X20122376"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-964995"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00421-015-3303-9"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/cpf.12437"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00421-007-0530-8"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00421-016-3384-0"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1519\/JSC.0000000000001662"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1249\/MSS.0000000000002147"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-989423"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1249\/00005768-198910000-00012"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.2337\/diacare.21.12.2116"},{"key":"e_1_2_9_20_1","volume-title":"ACSM's guidelines for exercise testing and prescription","author":"Liguori G.","year":"2021"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm10215073"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1249\/00005768-197323000-00012"},{"key":"e_1_2_9_23_1","first-page":"347","article-title":"Maximal oxygen uptake and aerobic\u2010anaerobic transition on treadmill and bicycle in triathletes","volume":"43","author":"Medelli J.","year":"1993","journal-title":"Japanese Journal of Physiology"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0145875"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2004.03.004"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1055\/a-0800-8633"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1590\/S0066-782X2011005000052"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1080\/02701367.1983.10605291"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.scispo.2017.06.005"},{"key":"e_1_2_9_30_1","first-page":"203","article-title":"Ventilatory thresholds determined from HRV: comparison of 2 methods in obese adolescents","volume":"35","author":"Quinart S.","year":"2014","journal-title":"International Journal of Sports Medicine"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.1249\/00005768-199312000-00021"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1186\/1758-5996-3-1"},{"key":"e_1_2_9_33_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006842-199507000-00004"},{"key":"e_1_2_9_34_1","first-page":"257","article-title":"Ventilatory threshold and maximal oxygen uptake during cycling and running in triathletes","volume":"22","author":"Schneider D.A.","year":"1990","journal-title":"Medicine and Science in Sports and Exercise"},{"key":"e_1_2_9_35_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-1024698"},{"key":"e_1_2_9_36_1","doi-asserted-by":"publisher","DOI":"10.3389\/fpubh.2017.00258"},{"key":"e_1_2_9_37_1","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.117.006612"},{"key":"e_1_2_9_38_1","doi-asserted-by":"publisher","DOI":"10.1002\/clc.22758"},{"key":"e_1_2_9_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2009.09.543"},{"key":"e_1_2_9_40_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.chest.2019.11.022"},{"key":"e_1_2_9_41_1","volume-title":"Physical activity guidelines for Americans","author":"US\u00a0Department of Health and Human Services. (","year":"2018"},{"key":"e_1_2_9_42_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0034-1398654"},{"key":"e_1_2_9_43_1","doi-asserted-by":"publisher","DOI":"10.1113\/jphysiol.2014.271858"}],"container-title":["Clinical Physiology and Functional Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/cpf.12760","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/cpf.12760","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/cpf.12760","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,25]],"date-time":"2023-08-25T06:53:54Z","timestamp":1692946434000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/cpf.12760"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,19]]},"references-count":42,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022,7]]}},"alternative-id":["10.1111\/cpf.12760"],"URL":"https:\/\/doi.org\/10.1111\/cpf.12760","archive":["Portico"],"relation":{},"ISSN":["1475-0961","1475-097X"],"issn-type":[{"value":"1475-0961","type":"print"},{"value":"1475-097X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,19]]},"assertion":[{"value":"2022-01-03","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-05-03","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-05-19","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}