{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,23]],"date-time":"2026-03-23T15:14:44Z","timestamp":1774278884392,"version":"3.50.1"},"reference-count":21,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2017,1,13]],"date-time":"2017-01-13T00:00:00Z","timestamp":1484265600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clinical Transplantation"],"published-print":{"date-parts":[[2017,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose<\/jats:title><jats:p>This study evaluates the selection, use, and risks of permanent and retrievable inferior vena cava filters (<jats:styled-content style=\"fixed-case\">IVCF<\/jats:styled-content>s) in patients who have undergone organ transplantation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and Methods<\/jats:title><jats:p>Single\u2010center retrospective review of 35 patients who had an <jats:styled-content style=\"fixed-case\">IVCF<\/jats:styled-content> placed following organ transplantation. Patient demographics, <jats:styled-content style=\"fixed-case\">IVCF<\/jats:styled-content> indication, and eligibility for retrieval were reviewed. Computed tomography (<jats:styled-content style=\"fixed-case\">CT<\/jats:styled-content>) studies showing the filter (n=22) were evaluated independently for <jats:styled-content style=\"fixed-case\">IVCF<\/jats:styled-content> adverse effects.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Thirty\u2010two (91%) of 35 patients had retrievable <jats:styled-content style=\"fixed-case\">IVCF<\/jats:styled-content>s placed while three (9%) patients received permanent <jats:styled-content style=\"fixed-case\">IVCF<\/jats:styled-content>s. Filter retrieval was indicated in three of the 32 patients receiving retrievable filters and was performed in two cases. Patients were ineligible for retrieval due to short life expectancy, complications\/contraindications to anticoagulation, extended filter dwell time, lost to follow\u2010up, and undetermined therapeutic value of anticoagulation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Current practices of filter placement usually dictate placing a retrievable <jats:styled-content style=\"fixed-case\">IVCF<\/jats:styled-content> in transplant patients. However, transplant patients are unlikely to be eligible for filter retrieval especially in situations of advanced age and comorbidities. Given the low incidence of eligibility for retrieval in this patient population, these results suggest preferential placement of permanent filters may reduce the potential morbidity due to filter\u2010related complications, such as strut perforation, in transplant patients.<\/jats:p><\/jats:sec>","DOI":"10.1111\/ctr.12865","type":"journal-article","created":{"date-parts":[[2017,1,13]],"date-time":"2017-01-13T16:57:32Z","timestamp":1484326652000},"source":"Crossref","is-referenced-by-count":2,"title":["Role of inferior vena cava filters in transplant patients"],"prefix":"10.1111","volume":"31","author":[{"given":"Joshua D.","family":"Dowell","sequence":"first","affiliation":[{"name":"Division of Interventional Radiology Department of Radiology The Ohio State University Wexner Medical Center  Columbus OH USA"},{"name":"Northwest Radiology St. Vincent Health  Indianapolis IN USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jordan C.","family":"Castle","sequence":"additional","affiliation":[{"name":"Division of Interventional Radiology Department of Radiology The Ohio State University Wexner Medical Center  Columbus OH USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jesse","family":"Spinner","sequence":"additional","affiliation":[{"name":"Division of Interventional Radiology Department of Radiology The Ohio State University Wexner Medical Center  Columbus OH USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sylvester","family":"Black","sequence":"additional","affiliation":[{"name":"Division of Transplant Surgery Department of Surgery The Ohio State University Wexner Medical Center  Columbus OH USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2017,1,13]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1177\/1076029614538490"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.transproceed.2013.07.017"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.transproceed.2012.06.060"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhep.2013.03.027"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMra072753"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.11-2301"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.216.1.r00jl1254"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-2006-941445"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2013.07.023"},{"key":"e_1_2_6_11_1","unstructured":"United States Food and Drug Administration.Removing Retrievable Inferior Vena Cava Filters: FDA Safety Communication.http:\/\/www.fda.gov\/MedicalDevices\/Safety\/AlertsandNotices\/ucm396377.htm. Accessed October 31 2015."},{"key":"e_1_2_6_12_1","first-page":"1499","article-title":"Quality improvement guidelines for the performance of inferior vena cava filter placement for the prevention of pulmonary embolism","volume":"22","author":"Caplin DM","year":"2011","journal-title":"J Vasc Interv Radiol"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-009-9684-6"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2012.04.017"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-015-1256-3"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-007-9184-5"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-014-1046-3"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2015.06.020"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2014.12.556"},{"key":"e_1_2_6_20_1","first-page":"1510","article-title":"Abstract 226: strut perforation of the Greenfield IVC filter","volume":"26","author":"Castle J","year":"2015","journal-title":"J Vasc Intervent Radiol."},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.5152\/dir.2016.16007"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvsv.2013.10.050"}],"container-title":["Clinical Transplantation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fctr.12865","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ctr.12865","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,3]],"date-time":"2023-10-03T17:45:49Z","timestamp":1696355149000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/ctr.12865"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1,13]]},"references-count":21,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2017,2]]}},"alternative-id":["10.1111\/ctr.12865"],"URL":"https:\/\/doi.org\/10.1111\/ctr.12865","archive":["Portico"],"relation":{},"ISSN":["0902-0063","1399-0012"],"issn-type":[{"value":"0902-0063","type":"print"},{"value":"1399-0012","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,1,13]]},"article-number":"e12865"}}