{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T19:39:03Z","timestamp":1788896343713,"version":"build-2803163510"},"reference-count":7,"publisher":"Wiley","issue":"S2","license":[{"start":{"date-parts":[[2013,4,25]],"date-time":"2013-04-25T00:00:00Z","timestamp":1366848000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Digestive Endoscopy"],"published-print":{"date-parts":[[2013,5]]},"abstract":"<jats:p>Various approaches to biliary drainage, especially endoscopic ultrasonography (<jats:styled-content style=\"fixed-case\">EUS<\/jats:styled-content>)\u2010guided drainage, have become commonly used as an alternative method for biliary decompression for malignant biliary obstruction. Occasionally, however, duodenal obstruction and non\u2010dilated intrahepatic bile duct impede conventional <jats:styled-content style=\"fixed-case\">EUS<\/jats:styled-content>\u2010guided biliary drainage. Herein, we describe a case of cholecystogastrostomy successfully carried out using a newly developed fully covered lumen\u2010apposing self\u2010expandable metallic stent (<jats:styled-content style=\"fixed-case\">SEMS<\/jats:styled-content>). <jats:styled-content style=\"fixed-case\">EUS<\/jats:styled-content>\u2010guided cholecystogastrostomy should be considered an option for biliary decompression. This is aparticularly ideal alternative if the patient has duodenal strictures with or without a duodenal metal stent and a non\u2010dilated intrahepatic bile duct, which suggests the impossibility of choledochoduodenostomy and hepaticogastrostomy. Furthermore, the newly developed fully covered lumen\u2010apposing <jats:styled-content style=\"fixed-case\">SEMS<\/jats:styled-content> seems ideal for <jats:styled-content style=\"fixed-case\">EUS<\/jats:styled-content>\u2010guided cholecystoenterostomy.<\/jats:p>","DOI":"10.1111\/den.12084","type":"journal-article","created":{"date-parts":[[2013,4,26]],"date-time":"2013-04-26T01:12:22Z","timestamp":1366938742000},"page":"137-141","source":"Crossref","is-referenced-by-count":38,"title":["Endoscopic ultrasonography\u2010guided cholecystogastrostomy using a lumen\u2010apposing metal stent as an alternative to extrahepatic bile duct drainage in pancreatic cancer with duodenal invasion"],"prefix":"10.1111","volume":"25","author":[{"given":"Takao","family":"Itoi","sequence":"first","affiliation":[{"name":"Department of Gastroenterology and Hepatology Tokyo Medical University  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenneth","family":"Binmoeller","sequence":"additional","affiliation":[{"name":"Interventional Endoscopy Services California Pacific Medical Center  San Francisco California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fumihide","family":"Itokawa","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology and Hepatology Tokyo Medical University  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junko","family":"Umeda","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology and Hepatology Tokyo Medical University  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reina","family":"Tanaka","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology and Hepatology Tokyo Medical University  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2013,4,25]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1443-1661.2011.01162.x"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00534-009-0196-1"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00534-010-0310-4"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2011.10.020"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2010.01.026"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00534-011-0410-9"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2011.03.1120"}],"container-title":["Digestive Endoscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fden.12084","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/den.12084","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,12]],"date-time":"2023-09-12T03:46:42Z","timestamp":1694490402000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/den.12084"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,4,25]]},"references-count":7,"journal-issue":{"issue":"S2","published-print":{"date-parts":[[2013,5]]}},"alternative-id":["10.1111\/den.12084"],"URL":"https:\/\/doi.org\/10.1111\/den.12084","archive":["Portico"],"relation":{},"ISSN":["0915-5635","1443-1661"],"issn-type":[{"value":"0915-5635","type":"print"},{"value":"1443-1661","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,4,25]]}}}