{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T05:10:51Z","timestamp":1767849051295,"version":"3.49.0"},"reference-count":26,"publisher":"Wiley","issue":"S1","license":[{"start":{"date-parts":[[2016,4,17]],"date-time":"2016-04-17T00:00:00Z","timestamp":1460851200000},"content-version":"vor","delay-in-days":16,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Digestive Endoscopy"],"published-print":{"date-parts":[[2016,4]]},"abstract":"<jats:p>Endoscopic retrograde cholangiopancreatography (ERCP) requires deep biliary cannulation. When deep biliary cannulation is failed, the endoscopic ultrasonography rendezvous technique (EUS\u2010RV) is a useful salvage method. <jats:styled-content>From the previous 15 articles<\/jats:styled-content> that included 382 <jats:styled-content>EUS\u2010RV<\/jats:styled-content> cases, the overall success rate of EUS\u2010RV is 81 % with a complication rate of 10 %. In EUS\u2010RV, the bile duct is punctured under EUS guidance and a guidewire is advanced into the duodenum via the papilla. The EUS scope is then switched to a duodenoscope and inserted into the bile duct over the guidewire exiting the papilla, or the guidewire is grasped with forceps and passed through the working channel; the catheter can then be inserted through the papilla over the wire. There are three puncture routes for EUS\u2010RV: transgastric puncture of the intrahepatic bile duct (IHBD), transduodenal puncture of the extrahepatic bile duct (EHBD) via the proximal duodenum (D1), and transduodenal puncture of the EHBD via the second portion of the duodenum (D2). The puncture route for each patient should be selected based on the patient condition. GW selection for EUS\u2010RV is critical, a hydrophilic GW is useful for this procedure. Although EUS\u2010RV is now performed relatively routinely in a few high\u2010volume centers, procedure standardization and the development of exclusive devices for EUS\u2010RV are still underway. The development of exclusive devices for EUS\u2010RV and prospective comparative studies with other salvage methods are needed to truly evaluate the procedure's usefulness and safety.<\/jats:p>","DOI":"10.1111\/den.12611","type":"journal-article","created":{"date-parts":[[2016,1,20]],"date-time":"2016-01-20T14:30:48Z","timestamp":1453300248000},"page":"96-101","source":"Crossref","is-referenced-by-count":76,"title":["Endoscopic ultrasonography\u2010guided rendezvous technique"],"prefix":"10.1111","volume":"28","author":[{"given":"Takayoshi","family":"Tsuchiya","sequence":"first","affiliation":[{"name":"Department of Gastroenterology and Hepatology Tokyo Medical University  Tokyo Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takao","family":"Itoi","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology and Hepatology Tokyo Medical University  Tokyo Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Atsushi","family":"Sofuni","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology and Hepatology Tokyo Medical University  Tokyo Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryosuke","family":"Tonozuka","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology and Hepatology Tokyo Medical University  Tokyo Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shuntaro","family":"Mukai","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology and Hepatology Tokyo Medical University  Tokyo Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2016,4,17]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cgh.2015.06.035"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/jgh.12303"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0034-1391228"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.1067\/mge.2001.118441"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0030-1256871"},{"key":"e_1_2_5_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2011.07.075"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00534-012-0577-8"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0016-5107(03)02300-9"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2006.01.063"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-995455"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0029-1214712"},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2008.12.233"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0029-1244082"},{"key":"e_1_2_5_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2011.08.032"},{"key":"e_1_2_5_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00464-013-2896-5"},{"key":"e_1_2_5_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2013.01.042"},{"key":"e_1_2_5_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2013.05.013"},{"key":"e_1_2_5_19_1","doi-asserted-by":"publisher","DOI":"10.1177\/2050640613480145"},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/den.12153"},{"key":"e_1_2_5_21_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0034-1391988"},{"key":"e_1_2_5_22_1","unstructured":"IwashitaT YasudaI MukaiTet al. EUS\u2010guided rendezvous for difficult biliary cannulation using a standardized algorithm: a multicenter prospective pilot study (with videos). Gastrointest Endosc. 2015 Jun 16 [Epub ahead of print]."},{"key":"e_1_2_5_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0016-5107(06)80108-2"},{"key":"e_1_2_5_24_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-2001-17324"},{"key":"e_1_2_5_25_1","doi-asserted-by":"publisher","DOI":"10.1067\/mge.2003.85"},{"key":"e_1_2_5_26_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-2003-44596"},{"key":"e_1_2_5_27_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12328-014-0467-5"}],"container-title":["Digestive Endoscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fden.12611","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/den.12611","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,11]],"date-time":"2023-09-11T20:41:43Z","timestamp":1694464903000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/den.12611"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,4]]},"references-count":26,"journal-issue":{"issue":"S1","published-print":{"date-parts":[[2016,4]]}},"alternative-id":["10.1111\/den.12611"],"URL":"https:\/\/doi.org\/10.1111\/den.12611","archive":["Portico"],"relation":{},"ISSN":["0915-5635","1443-1661"],"issn-type":[{"value":"0915-5635","type":"print"},{"value":"1443-1661","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,4]]}}}