{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T22:51:22Z","timestamp":1785538282041,"version":"3.56.0"},"reference-count":20,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2022,8,25]],"date-time":"2022-08-25T00:00:00Z","timestamp":1661385600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Digestive Endoscopy"],"published-print":{"date-parts":[[2023,1]]},"abstract":"<jats:sec><jats:title>Objectives<\/jats:title><jats:p>Interventional endoscopic ultrasonography is performed for various situations that require drainage, after which stent migration is the most severe adverse event. Several lumen\u2010apposing metal stents (LAMS) and covered self\u2010expandable metal stents (CSEMS) provide antimigration systems; however, their anchoring ability has not been studied well. Therefore, we measured and compared the anchoring force (ACF) of commercially available LAMS and CSEMS.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Anchoring force was measured for five types of LAMS (NAGI, SPAXUS, Plumber, and AXIOS 8 and 10\u2009mm) and seven types of CSEMS (BCL, SHCL, BCG, BPD [four types of HANAROSTENT], HILZO, Niti\u2010S [Spring Stopper], and Wallflex). We created a phantom model for inducing stent migration. It has a rotatable part as a curved fixture, and we measured ACF at angles between 0\u00b0 and 40\u00b0.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The mean ACF at 0\u00b0 and 20\u00b0 were NAGI 1.50, 1.84\u2009N, SPAXUS 1.73, 1.72\u2009N, Plumber 2.64, 2.03\u2009N, and AXIOS 3.96, 3.61\u2009N, respectively; and BCL 0.48, 0.53\u2009N, Wallflex 0.53, 0.48\u2009N, SHCL 0.64, 0.73\u2009N, HILZO 1.09, 1.09\u2009N, BCG 1.22, 1.20\u2009N, BPD 1.78, 1.67\u2009N, and Spring Stopper 2.29, 2.51\u2009N.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>We measured ACF in LAMS and CSEMS with a new phantom model. The highest value among the LAMS was for the AXIOS and among the CSEMS was for the Spring Stopper. Some of the ACF values varied with the direction of pull. These findings may have a significant impact on stent\u2009selection for interventional endoscopic ultrasonography, and this model can be used to evaluate newly developed stents.<\/jats:p><\/jats:sec>","DOI":"10.1111\/den.14406","type":"journal-article","created":{"date-parts":[[2022,7,15]],"date-time":"2022-07-15T07:41:51Z","timestamp":1657870911000},"page":"96-102","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Measurement of the anchoring force of covered self\u2010expandable and lumen\u2010apposing metal stents for interventional endoscopic ultrasonography"],"prefix":"10.1111","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5036-4545","authenticated-orcid":false,"given":"Yusuke","family":"Takasaki","sequence":"first","affiliation":[{"name":"Department of Gastroenterology, Graduate School of Medicine Juntendo University  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3308-9326","authenticated-orcid":false,"given":"Hiroyuki","family":"Isayama","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, Graduate School of Medicine Juntendo University  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyoung Sub","family":"Shin","sequence":"additional","affiliation":[{"name":"M.I.Tech Co., Ltd  Pyeongtaek South Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigeto","family":"Ishii","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, Graduate School of Medicine Juntendo University  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7367-0767","authenticated-orcid":false,"given":"Toshio","family":"Fujisawa","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, Graduate School of Medicine Juntendo University  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jong Pil","family":"Moon","sequence":"additional","affiliation":[{"name":"M.I.Tech Co., Ltd  Pyeongtaek South Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taito","family":"Fukuma","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, Graduate School of Medicine Juntendo University  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mako","family":"Ushio","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, Graduate School of Medicine Juntendo University  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sho","family":"Takahashi","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, Graduate School of Medicine Juntendo University  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akinori","family":"Suzuki","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, Graduate School of Medicine Juntendo University  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koichi","family":"Ito","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, Graduate School of Medicine Juntendo University  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ko","family":"Tomishima","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, Graduate School of Medicine Juntendo University  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2022,8,25]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1002\/jhbp.631"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2021.09.040"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2016.08.028"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0029-1243911"},{"issue":"1","key":"e_1_2_8_6_1","first-page":"E311","article-title":"Stent migration into the peritoneal cavity following endoscopic ultrasound\u2010guided hepaticogastrostomy","volume":"47","author":"Okuno N","year":"2015","journal-title":"Endoscopy"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2017.03.023"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm10143111"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0042-116595"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2020.03.3856"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11605-018-3758-1"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/den.13621"},{"issue":"1","key":"e_1_2_8_13_1","first-page":"E563","article-title":"Crisscross anchor\u2010stents to prevent metal stent migration during endoscopic ultrasound\u2010guided hepaticogastrostomy","volume":"46","author":"Shima Y","year":"2014","journal-title":"Endoscopy"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/den.14077"},{"key":"e_1_2_8_15_1","doi-asserted-by":"crossref","first-page":"275","DOI":"10.4103\/sjg.sjg_81_21","article-title":"Usefulness of routine plain CT the day after an interventional EUS procedure","volume":"27","author":"Kiyanagi A","year":"2021","journal-title":"Saudi J Gastroenterol"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2015.11.041"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/jgh.14307"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.3748\/wjg.v22.i30.6917"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2021.07.021"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1177\/2050640618785078"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.3748\/wjg.v20.i17.5051"}],"container-title":["Digestive Endoscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/den.14406","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/den.14406","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/den.14406","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,20]],"date-time":"2023-08-20T17:11:54Z","timestamp":1692551514000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/den.14406"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,25]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023,1]]}},"alternative-id":["10.1111\/den.14406"],"URL":"https:\/\/doi.org\/10.1111\/den.14406","archive":["Portico"],"relation":{},"ISSN":["0915-5635","1443-1661"],"issn-type":[{"value":"0915-5635","type":"print"},{"value":"1443-1661","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,25]]},"assertion":[{"value":"2022-03-12","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-07-11","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-08-25","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}