{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,14]],"date-time":"2026-03-14T01:18:30Z","timestamp":1773451110079,"version":"3.50.1"},"reference-count":20,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2025,1,24]],"date-time":"2025-01-24T00:00:00Z","timestamp":1737676800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["dom-pubs.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Diabetes Obesity Metabolism"],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aims<\/jats:title>\n                    <jats:p>Physiological changes during pregnancy can infuence the performance of blood glucose meters. This study aimed to evaluate the analytical and clinical accuracy of glucose meters in pregnant women with hyperglycaemia.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>Glucose was measured by four commonly used meters among consecutive women with diabetes in pregnancy. Capillary and venous samples were collected concurrently and compared with i\u2010STAT (amperometry) and laboratory (hexokinase) glucose as reference methods. Bland\u2013Altman plot, International Organization for Standardization criteria, surveillance error grid (SEG) and haematocrit influence were assessed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      In total, 824 paired samples from 103 women were analysed (GDM 57%, mean i\u2010STAT capillary glucose 6.7\u2009\u00b1\u20092.3\u2009mmol\/L [121\u2009\u00b1\u200941\u2009mg\/dL], laboratory glucose 6.6\u2009\u00b1\u20092.4\u2009mmol\/L [119\u2009\u00b1\u200943\u2009mg\/dL], median haematocrit 0.36\u2009L\/L). Mean capillary glucose measured on all meters was significantly different from that measured on i\u2010STAT (all\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001), whereas venous glucose measured on Contour Next, Accu\u2010Chek Guide and the laboratory (plasma) was similar. Contour Next had the lowest bias when using both reference methods (mean bias [95% limits of agreement] meter vs. i\u2010STAT: Contour Next 1.3% [\u22128% to 10.6%], Accu\u2010Chek Guide \u22123.2% [\u221211.4% to 5%], FreeStyle Optium Neo \u221211.9% [\u221224.7% to 0.8%] and LifeSmart 6.8% [\u22125.8% to 19.4%]; meter versus laboratory: \u22120.2% [\u22128.1% to 7.7%], \u22120.2% [\u221210.2% to 9.8%], \u22123.8% [\u221217.6% to 10%] and 6.1% [\u22125.9% to 18.2%]), respectively. Only Contour Next and Accu\u2010Chek Guide had \u226597% of pairs within the SEG no\u2010risk zone during both comparisons. Meters did not show haematocrit\u2010related bias.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Accuracy of meters was higher when using venous samples than when using capillary samples. Contour Next and Accu\u2010Chek Guide meters met accuracy standards in all analyses.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/dom.16209","type":"journal-article","created":{"date-parts":[[2025,1,24]],"date-time":"2025-01-24T03:48:54Z","timestamp":1737690534000},"page":"2131-2137","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Evaluation of the analytical and clinical accuracy of four blood glucose meters in pregnant women with hyperglycaemia"],"prefix":"10.1111","volume":"27","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2020-4791","authenticated-orcid":false,"given":"Jincy","family":"Immanuel","sequence":"first","affiliation":[{"name":"School of Medicine Western Sydney University  Campbelltown New South Wales Australia"},{"name":"College of Nursing Texas Woman's University  Denton Texas USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tobias","family":"Kongbrailatpam","sequence":"additional","affiliation":[{"name":"School of Medicine Western Sydney University  Campbelltown New South Wales Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rohit","family":"Rajagopal","sequence":"additional","affiliation":[{"name":"Department of Endocrinology Campbelltown Hospital  Sydney New South Wales Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Simmons","sequence":"additional","affiliation":[{"name":"School of Medicine Western Sydney University  Campbelltown New South Wales Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,1,24]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000023793"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1177\/193229680900300446"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1177\/1932296816672237"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1177\/193229681000400111"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.2337\/dc18-0833"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/ijgo.12399"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.4103\/njcp.njcp_221_19"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.2147\/DMSO.S389420"},{"key":"e_1_2_10_10_1","article-title":"Accuracy of five plasma calibrated glucometers to screen for and diagnose gestational diabetes mellitus in a low resource clinic setting","volume":"16","author":"Dickson LM","year":"2018","journal-title":"J Clin Transl Endocrinol"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00592-015-0761-9"},{"key":"e_1_2_10_12_1","unstructured":"Abbott Point of Care Inc. I\u2010STAT G Cartridge [Internet].2020.https:\/\/www.globalpointofcare.abbott\/content\/dam\/ardx\/globalpointofcare\/apoc\/support\/i\u2010stat\u20101\/cti\u2010ifu\/english\u2010uk\/ifu\/765790\u201001A.pdf"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.2337\/dc10-1457"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.2337\/dc17-1960"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2011.0097"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1177\/0004563213487893"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1159\/000276572"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/ijgo.13178"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/1471-0528.14255"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1093\/clinchem\/hvz005"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1038\/srep16302"}],"container-title":["Diabetes, Obesity and Metabolism"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dom-pubs.pericles-prod.literatumonline.com\/doi\/pdf\/10.1111\/dom.16209","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T06:53:27Z","timestamp":1761893607000},"score":1,"resource":{"primary":{"URL":"https:\/\/dom-pubs.pericles-prod.literatumonline.com\/doi\/10.1111\/dom.16209"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,24]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,4]]}},"alternative-id":["10.1111\/dom.16209"],"URL":"https:\/\/doi.org\/10.1111\/dom.16209","archive":["Portico"],"relation":{"has-review":[{"id-type":"doi","id":"10.1111\/DOM.16209\/v2\/response1","asserted-by":"object"},{"id-type":"doi","id":"10.1111\/DOM.16209\/v1\/decision1","asserted-by":"object"},{"id-type":"doi","id":"10.1111\/DOM.16209\/v1\/review1","asserted-by":"object"},{"id-type":"doi","id":"10.1111\/DOM.16209\/v2\/decision1","asserted-by":"object"}]},"ISSN":["1462-8902","1463-1326"],"issn-type":[{"value":"1462-8902","type":"print"},{"value":"1463-1326","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,24]]},"assertion":[{"value":"2024-10-21","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-12","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-24","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}