{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T18:15:20Z","timestamp":1695492920422},"reference-count":9,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2015,6,24]],"date-time":"2015-06-24T00:00:00Z","timestamp":1435104000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Echocardiography"],"published-print":{"date-parts":[[2015,10]]},"abstract":"<jats:p>Platypnea\u2013orthodeoxia syndrome (<jats:styled-content style=\"fixed-case\">POS<\/jats:styled-content>) is a rare clinical disorder characterized by dyspnea caused by the upright position and relieved at recumbent position. Few cases of <jats:styled-content style=\"fixed-case\">POS<\/jats:styled-content> and stroke were reported in literature, and the association between stroke and <jats:styled-content style=\"fixed-case\">POS<\/jats:styled-content> with evidence of patent foramen ovale (<jats:styled-content style=\"fixed-case\">PFO<\/jats:styled-content>) is rare. Stroke may occur in patients with cardiac shunt who undergo contrast echocardiography. We present a patient with <jats:styled-content style=\"fixed-case\">POS<\/jats:styled-content> who experienced transitory ischemic attack (<jats:styled-content style=\"fixed-case\">TIA<\/jats:styled-content>) most likely caused by injection of agitated saline microbubbles during screen for <jats:styled-content style=\"fixed-case\">PFO<\/jats:styled-content>. No case report of <jats:styled-content style=\"fixed-case\">TIA<\/jats:styled-content>\/stroke during contrast echocardiography in patients with <jats:styled-content style=\"fixed-case\">POS<\/jats:styled-content> has previously been published.<\/jats:p>","DOI":"10.1111\/echo.12970","type":"journal-article","created":{"date-parts":[[2015,6,25]],"date-time":"2015-06-25T04:28:57Z","timestamp":1435206537000},"page":"1585-1587","source":"Crossref","is-referenced-by-count":5,"title":["TIA Caused by Contrast Echocardiography in Patient with Platypnea\u2013Orthodeoxia"],"prefix":"10.1111","volume":"32","author":[{"given":"Goran","family":"Loncar","sequence":"first","affiliation":[{"name":"Institute of Cardiology University Hospital Pitie Salpetriere Paris France"},{"name":"Cardiology Department Clinical Hospital Zvezdara Belgrade Serbia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laurent","family":"Payot","sequence":"additional","affiliation":[{"name":"Institute of Cardiology University Hospital Pitie Salpetriere Paris France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mathieu","family":"Dubois","sequence":"additional","affiliation":[{"name":"Department of Pneumology University Hospital Pitie Salpetriere Paris France"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2015,6,24]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1161\/circ.105.6.e47"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10072-011-0572-x"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1447-0594.2011.00758.x"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.109.549683"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8175.2006.00272.x"},{"key":"e_1_2_5_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2014.05.011"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1525-2167(03)00048-9"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2013.05.042"},{"key":"e_1_2_5_10_1","first-page":"578","article-title":"Management of platypnea\u2010orthodeoxia syndrome by transcatheter closure of atrial communication: hemodynamic characteristics, clinical and echocardiographic outcome","volume":"16","author":"Delgado G","year":"2004","journal-title":"J Invasive Cardiol"}],"container-title":["Echocardiography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fecho.12970","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/echo.12970","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T17:57:20Z","timestamp":1695491840000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/echo.12970"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,6,24]]},"references-count":9,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2015,10]]}},"alternative-id":["10.1111\/echo.12970"],"URL":"https:\/\/doi.org\/10.1111\/echo.12970","archive":["Portico"],"relation":{},"ISSN":["0742-2822","1540-8175"],"issn-type":[{"value":"0742-2822","type":"print"},{"value":"1540-8175","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,6,24]]}}}