{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T05:25:04Z","timestamp":1783574704504,"version":"3.55.0"},"reference-count":27,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2017,3,16]],"date-time":"2017-03-16T00:00:00Z","timestamp":1489622400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Echocardiography"],"published-print":{"date-parts":[[2017,5]]},"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Patients (pts) scheduled for coronary artery bypass grafting, burdened with high risk of carotid stenosis, are recommended to undergo duplex ultrasonography (DUS) of carotid arteries.<\/jats:p><\/jats:sec><jats:sec><jats:title>Purpose<\/jats:title><jats:p>To validate pocket\u2010size imaging device (PSID) equipped with linear probe as an easily accessible tool enabling bedside screening for carotid artery stenosis (CAS).<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>A total of 100 pts (60 men, mean age 69\u00b111\u00a0years) with multivessel coronary artery disease underwent bedside DUS of carotid arteries with the use of PSID performed by a cardiology resident trained in DUS. Subsequently, DUS with the use of stationary high\u2010end ultrasound system was performed in all pts to verify findings of PSID examination.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Initial diagnosis of atherosclerotic plaque presence obtained with PSID in 59 patients was confirmed by high\u2010end ultrasound system examination in all cases. There was a statistically significant correlation of intima\u2010media thickness measurements between PSID and stationary system (<jats:italic>r<\/jats:italic>=.58; 95% CI: 0.48\u20130.66; <jats:italic>P<\/jats:italic>&lt;.0001), but the coefficient of agreement (\u03ba) between the two methods in classification of intima\u2010media as normal or thickened (&gt;0.9\u00a0mm) was only .38 (95% CI: 0.299\u20130.459). During PSID examination, turbulent flow was observed in 21 pts\u2014CAS was confirmed in all these pts\u20145 pts were diagnosed with significant CAS, the rest with CAS ranging from 30% to 70%.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Pocket\u2010size imaging device equipped with linear probe allows for identification of patients with atherosclerotic plaques and turbulent flow in carotid arteries; however, the degree of CAS cannot be reliably determined. The measurement accuracy of intima\u2010media thickness is insufficient for a diagnostic purpose.<\/jats:p><\/jats:sec>","DOI":"10.1111\/echo.13507","type":"journal-article","created":{"date-parts":[[2017,3,16]],"date-time":"2017-03-16T08:36:50Z","timestamp":1489653410000},"page":"716-722","source":"Crossref","is-referenced-by-count":9,"title":["Bedside screening with the use of pocket\u2010size imaging device can be useful for ruling out carotid artery stenosis in patients scheduled for cardiac surgery"],"prefix":"10.1111","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5760-1243","authenticated-orcid":false,"given":"Dominika","family":"Filipiak\u2010Strzecka","sequence":"first","affiliation":[{"name":"Department of Cardiology Bieganski Hospital Medical University of Lodz  Lodz Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaros\u0142aw D.","family":"Kasprzak","sequence":"additional","affiliation":[{"name":"Department of Cardiology Bieganski Hospital Medical University of Lodz  Lodz Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ewa","family":"Szymczyk","sequence":"additional","affiliation":[{"name":"Department of Cardiology Bieganski Hospital Medical University of Lodz  Lodz Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paulina","family":"Wejner\u2010Mik","sequence":"additional","affiliation":[{"name":"Department of Cardiology Bieganski Hospital Medical University of Lodz  Lodz Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Piotr","family":"Lipiec","sequence":"additional","affiliation":[{"name":"Department of Cardiology Bieganski Hospital Medical University of Lodz  Lodz Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2017,3,16]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2004.07.027"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehu282"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehu278"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2011.08.008"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1253\/circj.CJ-08-1076"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8175.2011.01559.x"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/uog.11184"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultrasmedbio.2014.06.022"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2004.11.015"},{"key":"e_1_2_7_11_1","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1053\/euje.4.2.141","article-title":"The use of small personal ultrasound devices by internists without formal training in echocardiography","volume":"4","author":"DeCara JM","year":"2003","journal-title":"Eur J Echocardiogr"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.2478\/v10039-012-0054-2"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1093\/ejechocard\/jeq184"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2292030516"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/HCO.0b013e32834a7035"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2014.11.043"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2004.02.024"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2015.09.108"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/eht296"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.7863\/ultra.33.7.1273"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-147-12-200712180-00005"},{"key":"e_1_2_7_22_1","first-page":"25","article-title":"Screening of carotid artery stenosis in coronary artery bypass grafting patients","volume":"5","author":"Salehiomran A","year":"2010","journal-title":"J Tehran Heart Cent"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(00)02132-9"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.atherosclerosis.2013.01.025"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2012.9630"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0122181"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2014.08.001"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehr211"}],"container-title":["Echocardiography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fecho.13507","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/echo.13507","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,2]],"date-time":"2023-10-02T07:44:18Z","timestamp":1696232658000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/echo.13507"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3,16]]},"references-count":27,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2017,5]]}},"alternative-id":["10.1111\/echo.13507"],"URL":"https:\/\/doi.org\/10.1111\/echo.13507","archive":["Portico"],"relation":{},"ISSN":["0742-2822","1540-8175"],"issn-type":[{"value":"0742-2822","type":"print"},{"value":"1540-8175","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,3,16]]}}}