{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T01:00:10Z","timestamp":1747184410408,"version":"3.40.5"},"reference-count":4,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2019,2,18]],"date-time":"2019-02-18T00:00:00Z","timestamp":1550448000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Echocardiography"],"published-print":{"date-parts":[[2019,4]]},"abstract":"<jats:p>Entrapment of coronary angioplasty hardware is a rare but serious complication of coronary interventions which may be managed percutaneously or surgically. We described a case of an entrapped coronary stent in a patient with a history of failed coronary intervention with no documents available. In transesophageal echocardiography, there was a linear echo density in the ascending aorta stuck in the right coronary artery resembling a dissection flap but based on the history of failed coronary intervention, this odd structure was supposed to be a retained angioplasty device. The patient underwent surgical removal of the entrapped device which was a fractured stent.<\/jats:p>","DOI":"10.1111\/echo.14296","type":"journal-article","created":{"date-parts":[[2019,2,19]],"date-time":"2019-02-19T02:31:00Z","timestamp":1550543460000},"page":"806-808","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Retained entrapped coronary stent appearing like an aortic flap"],"prefix":"10.1111","volume":"36","author":[{"given":"Shokoufeh","family":"Hajsadeghi","sequence":"first","affiliation":[{"name":"Research Center for Prevention of Cardiovascular Disease Institute of Endocrinology &amp; Metabolism Iran University Of Medical Sciences  Tehran Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9519-8854","authenticated-orcid":false,"given":"Marziyeh","family":"Pakbaz","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Disease Hazrat\u2010e Rasool General Hospital Iran University of Medical Sciences  Tehran Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mehrab","family":"Marzban","sequence":"additional","affiliation":[{"name":"Iranian Society of Cardiac Surgeons  Tehran Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nematollah","family":"Pourebrahim","sequence":"additional","affiliation":[{"name":"Iranmehr Hospital  Tehran Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2019,2,18]]},"reference":[{"key":"e_1_2_2_2_1","doi-asserted-by":"publisher","DOI":"10.1177\/0218492314546496"},{"key":"e_1_2_2_3_1","first-page":"215","article-title":"Frequency, treatment, and consequences of device loss and entrapment in contemporary percutaneous coronary interventions","volume":"24","author":"Iturbe JM","year":"2012","journal-title":"J Invasive Cardiol"},{"key":"e_1_2_2_4_1","first-page":"190","article-title":"Stent entrapment and guide wire fracture during percutaneous coronary intervention in the same patient","volume":"9","author":"Tamci B","year":"2013","journal-title":"Postep Kardiol Inter"},{"key":"e_1_2_2_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.0742-2822.2005.04027.x"}],"container-title":["Echocardiography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fecho.14296","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/echo.14296","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/echo.14296","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/echo.14296","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,10]],"date-time":"2023-09-10T12:06:12Z","timestamp":1694347572000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/echo.14296"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,18]]},"references-count":4,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019,4]]}},"alternative-id":["10.1111\/echo.14296"],"URL":"https:\/\/doi.org\/10.1111\/echo.14296","archive":["Portico"],"relation":{},"ISSN":["0742-2822","1540-8175"],"issn-type":[{"type":"print","value":"0742-2822"},{"type":"electronic","value":"1540-8175"}],"subject":[],"published":{"date-parts":[[2019,2,18]]},"assertion":[{"value":"2018-10-25","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-02-01","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-02-18","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}