{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T05:51:12Z","timestamp":1760161872600,"version":"3.40.5"},"reference-count":35,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2020,9,23]],"date-time":"2020-09-23T00:00:00Z","timestamp":1600819200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Echocardiography"],"published-print":{"date-parts":[[2020,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>The purpose of this paper was to evaluate the difference in postoperative outcomes following multidetector computed tomography (MDCT) and transesophageal echocardiography (TEE)\u2010based annulus sizing for transcatheter aortic valve replacement (TAVR).<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Electronic search of PubMed, Biomed Central, Scopus, and Google Scholar databases was conducted until August 15, 2019. We included all types of studies comparing MDCT\u2010based annulus sizing with TEE\u2010based annulus sizing and assessing paravalvular regurgitation (PVR). Data were summarized using the Mantel\u2010Haenszel odds ratio (OR) with 95% confidence intervals (CI).<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>A total of six studies were included. Pooled analysis of 431 participants in the MDCT group and 509 participants in the TEE group demonstrated that MDCT\u2010based annulus sizing is associated with a significantly lower incidence of more than moderate PVR as compared to 2DTEE\u2010based sizing (OR: 0.31, 95% CI: 0.18\u20100.54, <jats:italic>P<\/jats:italic>\u00a0&lt;\u00a0.0001; <jats:italic>I<\/jats:italic><jats:sup>2<\/jats:sup>\u00a0=\u00a00%). There was no statistical difference in annulus rupture (OR: 0.57, 95% CI: 0.12\u20102.66, <jats:italic>P<\/jats:italic>\u00a0=\u00a0.91; <jats:italic>I<\/jats:italic><jats:sup>2<\/jats:sup>\u00a0=\u00a00%), procedural mortality (OR: 0.97, 95% CI: 0.19\u20104.86, <jats:italic>P<\/jats:italic>\u00a0=\u00a0.97; I<jats:sup>2<\/jats:sup>\u00a0=\u00a00%), and 30\u2010day mortality (OR: 0.63, 95% CI: 0.26\u20101.50, <jats:italic>P<\/jats:italic>\u00a0=\u00a0.29; <jats:italic>I<\/jats:italic><jats:sup>2<\/jats:sup>\u00a0=\u00a00%) with MDCT or 2DTEE\u2010based annulus sizing. Compared with 3DTEE, the incidence of PVR in the MDCT group was lower, but there was no statistical difference in 30\u2010day mortality.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Use of MDCT in comparison with 2DTEE is associated with significantly lower incidence of more than moderate PVR after TAVR. There seems to be no difference in annulus rupture and 30\u2010day mortality with either imaging modality.<\/jats:p><\/jats:sec>","DOI":"10.1111\/echo.14684","type":"journal-article","created":{"date-parts":[[2020,9,23]],"date-time":"2020-09-23T15:18:35Z","timestamp":1600874315000},"page":"1617-1626","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Comparison of postoperative outcomes following multidetector computed tomography based vs transesophageal echocardiography based annulus sizing for transcatheter aortic valve replacement: A systematic review and meta\u2010analysis"],"prefix":"10.1111","volume":"37","author":[{"given":"Guozhang","family":"Tang","sequence":"first","affiliation":[{"name":"Department of Echocardiography The Affiliated Hospital of Qingdao University Qingdao China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qifeng","family":"Lv","sequence":"additional","affiliation":[{"name":"Department of Echocardiography The Affiliated Hospital of Qingdao University Qingdao China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1000-5879","authenticated-orcid":false,"given":"Xiangqin","family":"He","sequence":"additional","affiliation":[{"name":"Department of Echocardiography The Affiliated Hospital of Qingdao University Qingdao China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2020,9,23]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.3109\/14017431.2012.731519"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2012.02.022"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.110.946533"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2009.06.063"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.111.967349"},{"issue":"1","key":"e_1_2_5_7_1","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.jcmg.2007.09.004","article-title":"Role of echocardiography in percutaneous aortic valve implantation","volume":"1","author":"Moss RR","year":"2008","journal-title":"JACC Cardiovasc Imaging"},{"key":"e_1_2_5_8_1","first-page":"G6","article-title":"Cardiac CT: necessary for precise sizing for transcatheter aortic implantation","volume":"6","author":"Schultz CJ","year":"2010","journal-title":"EuroIntervention"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/cpf.12200"},{"issue":"9","key":"e_1_2_5_10_1","doi-asserted-by":"crossref","first-page":"1114","DOI":"10.1093\/eurheartj\/ehq018","article-title":"Transcatheter aortic valve implantation: role of multi\u2010detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function","volume":"31","author":"Delgado V","year":"2010","journal-title":"Eur Heart J"},{"issue":"6","key":"e_1_2_5_11_1","doi-asserted-by":"crossref","first-page":"652","DOI":"10.1016\/j.jcin.2014.02.010","article-title":"Erroneous measurement of the aortic annular diameter using 2\u2010dimensional echocardiography resulting in inappropriate CoreValve size selection: a retrospective comparison with multislice computed tomography","volume":"7","author":"Mylotte D","year":"2014","journal-title":"JACC Cardiovasc Interv"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.119.013463"},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcct.2012.10.002"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2011.09.010"},{"key":"e_1_2_5_15_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pmed.1000097"},{"volume-title":"Cochrane Handbook for Systemic Reviews of Interventions","year":"2011","author":"Higgins J","key":"e_1_2_5_16_1"},{"key":"e_1_2_5_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinepi.2012.09.016"},{"volume-title":"Cochrane Handbook for Systemic Reviews of Interventions","year":"2011","author":"Higgins J","key":"e_1_2_5_18_1"},{"key":"e_1_2_5_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2014.04.220"},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.4244\/EIJV8I5A85"},{"issue":"9","key":"e_1_2_5_21_1","doi-asserted-by":"crossref","first-page":"1633","DOI":"10.1016\/j.amjcard.2017.07.062","article-title":"Evaluation of imaging strategy to optimize and improve outcome of transcatheter aortic valvular implantation","volume":"120","author":"Casset C","year":"2017","journal-title":"Am J Cardiol"},{"key":"e_1_2_5_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2013.04.036"},{"key":"e_1_2_5_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.25005"},{"key":"e_1_2_5_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2011.11.045"},{"key":"e_1_2_5_25_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00392-019-01462-6"},{"key":"e_1_2_5_26_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.112.142000"},{"issue":"10","key":"e_1_2_5_27_1","first-page":"838","article-title":"Transcatheter aortic valve replacement versus surgical aortic valve replacement in low\u2010surgical\u2010risk patients: an updated meta\u2010analysis","volume":"20","author":"Goel S","year":"2019","journal-title":"Catheter Cardiovasc Interv"},{"key":"e_1_2_5_28_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1200384"},{"key":"e_1_2_5_29_1","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.2010.217158"},{"key":"e_1_2_5_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.23181"},{"issue":"3","key":"e_1_2_5_31_1","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1016\/j.athoracsur.2010.09.038","article-title":"Preoperative assessment of aortic annulus dimensions: comparison of noninvasive and intraoperative measurement","volume":"91","author":"Dashkevich A","year":"2011","journal-title":"Ann Thorac Surg"},{"key":"e_1_2_5_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcmg.2011.12.013"},{"issue":"9","key":"e_1_2_5_33_1","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1007\/s12471-018-1133-1","article-title":"Short versus conventional hydration for prevention of kidney injury during pre\u2010TAVI computed tomography angiography","volume":"26","author":"Mourik MS","year":"2018","journal-title":"Netherlands Heart J"},{"key":"e_1_2_5_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2017.09.001"},{"key":"e_1_2_5_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2016.07.001"},{"key":"e_1_2_5_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2016.10.012"}],"container-title":["Echocardiography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/echo.14684","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/echo.14684","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/echo.14684","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,4]],"date-time":"2023-09-04T20:18:48Z","timestamp":1693858728000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/echo.14684"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,23]]},"references-count":35,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2020,10]]}},"alternative-id":["10.1111\/echo.14684"],"URL":"https:\/\/doi.org\/10.1111\/echo.14684","archive":["Portico"],"relation":{},"ISSN":["0742-2822","1540-8175"],"issn-type":[{"type":"print","value":"0742-2822"},{"type":"electronic","value":"1540-8175"}],"subject":[],"published":{"date-parts":[[2020,9,23]]},"assertion":[{"value":"2020-02-25","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-04-20","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-09-23","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}