{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T14:40:09Z","timestamp":1791211209424,"version":"4.1.0"},"reference-count":37,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2013,7,4]],"date-time":"2013-07-04T00:00:00Z","timestamp":1372896000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dental Traumatology"],"published-print":{"date-parts":[[2014,4]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>The aim of this study was to compare the accuracy of cone beam computed tomography (CBCT) and multislice computed tomography (MSCT) in diagnosing factitious fractures in maxillofacial region as well as to investigate the influence of field of view (FOV) size on the interpretation of maxillofacial fractures in CBCT.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Simulated fractures were created in the right and left sides of five dried human skulls using a micro\u2010saw 20\u00a0mm blade without displacement. The skulls were scanned with a spiral 16\u2010slice MSCT scanner and a CBCT device with two FOVs (6\u00a0\u00d7\u00a06, 15\u00a0\u00d7\u00a015). Three observers assessed and interpreted the images judging whether fracture was present or absent. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and the area under the receiver operating characteristic (ROC) curve were calculated.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The sensitivity of CBCT 6\u00a0\u00d7\u00a06, CBCT 15\u00a0\u00d7\u00a015, and MSCT was 87.5%, 70.7%, and 49.7% and the specificity of three modalities was 91.7%, 88.0%, and 98.3%, respectively. The area under ROC curve was 0.90 (95% CI: 0.85, 0.94) for CBCT with FOV 6\u00a0\u00d7\u00a06, 0.79 (95% CI: 0.75, 0.85) for CBCT with FOV 15\u00a0\u00d7\u00a015, and 0.74 (95% CI: 0.69, 0.79) for MSCT. The Kappa value for interobserver agreement was highest for CBCT 6\u00a0\u00d7\u00a06 among imaging modalities.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>CBCT with small FOV had higher diagnostic accuracy in detecting simulated maxillofacial fractures than MSCT. However, additional evidence based on <jats:italic>in vivo<\/jats:italic> studies is needed to confirm the superiority of CBCT on MSCT in diagnosis of maxillofacial traumatic fractures.<\/jats:p><\/jats:sec>","DOI":"10.1111\/edt.12058","type":"journal-article","created":{"date-parts":[[2013,7,5]],"date-time":"2013-07-05T03:26:59Z","timestamp":1372994819000},"page":"162-168","source":"Crossref","is-referenced-by-count":13,"title":["Comparison between cone beam computed tomography and multislice computed tomography in diagnostic accuracy of maxillofacial fractures in dried human skull: an <i>in vitro<\/i> study"],"prefix":"10.1111","volume":"30","author":[{"given":"Amir","family":"Eskandarlou","sequence":"first","affiliation":[{"name":"Department of Dentomaxillofacial Radiology School of Dentistry, Hamadan University of Medical Sciences Hamadan Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jalal","family":"Poorolajal","sequence":"additional","affiliation":[{"name":"Department of Epidemiology &amp; Biostatistics Research Center for Health Sciences, School of Public Health, Hamadan University of Medical Sciences Hamadan Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmad Reza","family":"Talaeipour","sequence":"additional","affiliation":[{"name":"Department of Dentomaxillofacial Radiology Dental Branch, Islamic Azad University Tehran Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sahar","family":"Talebi","sequence":"additional","affiliation":[{"name":"Department of Dentomaxillofacial Radiology School of Dentistry, Hamadan University of Medical Sciences Hamadan Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maziar","family":"Talaeipour","sequence":"additional","affiliation":[{"name":"Department of periodontology Dental Branch, Islamic Azad University Tehran Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2013,7,4]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-9657.2009.00795.x"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joms.2010.07.081"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tripleo.2006.05.008"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-9657.2006.00509.x"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cden.2009.07.001"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.TA.0000141874.73520.A6"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tripleo.2005.05.057"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2009.03.042"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/29930707"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tripleo.2007.05.004"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tripleo.2010.05.053"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/27546065"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/24985971"},{"key":"e_1_2_7_15_1","volume-title":"Radiologic science for technologists physics, biology and protection","author":"Bushong SC","year":"2008"},{"key":"e_1_2_7_16_1","volume-title":"Oral rdiology: principles and Interpretation","author":"White SC","year":"2009"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.oooo.2012.05.026"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bjoms.2008.05.005"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1038\/sj.dmfr.4600593"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1590\/S1678-77572010000300012"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/22818643"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tripleo.2009.02.034"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinimag.2006.09.029"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tripleo.2011.04.001"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tripleo.2009.07.009"},{"key":"e_1_2_7_26_1","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1016\/S1010-5182(06)60071-1","article-title":"CT scan or cone beam tomography for orbital wall fracture diagnosis? An in vitro investigation","volume":"34","author":"Aref A","year":"2006","journal-title":"J Craniomaxillofac Surg"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/54013049"},{"key":"e_1_2_7_28_1","first-page":"153","article-title":"On the correlation of pixel noise, spatial resolution and dose in computed tomography: theoretical prediction and verification by simulation and measurement","volume":"19","author":"Fuchs T","year":"2003","journal-title":"Physica Med"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/23496562"},{"key":"e_1_2_7_30_1","first-page":"446","article-title":"A comparison of jaw dimensional and quality assessments of bone characteristics with cone\u2010beam CT, spiral tomography, and multi\u2010slice spiral CT","volume":"22","author":"Loubele M","year":"2007","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcms.2010.06.009"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joms.2004.05.215"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/15309653"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joms.2008.06.086"},{"key":"e_1_2_7_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrex.2011.04.013"},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijom.2009.07.013"},{"key":"e_1_2_7_37_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/54020205"},{"key":"e_1_2_7_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijom.2004.09.010"}],"container-title":["Dental Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fedt.12058","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/edt.12058","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,3]],"date-time":"2023-10-03T01:41:17Z","timestamp":1696297277000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/edt.12058"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,7,4]]},"references-count":37,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2014,4]]}},"alternative-id":["10.1111\/edt.12058"],"URL":"https:\/\/doi.org\/10.1111\/edt.12058","archive":["Portico"],"relation":{},"ISSN":["1600-4469","1600-9657"],"issn-type":[{"value":"1600-4469","type":"print"},{"value":"1600-9657","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,7,4]]}}}