{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T18:48:18Z","timestamp":1773254898936,"version":"3.50.1"},"reference-count":20,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2025,5,25]],"date-time":"2025-05-25T00:00:00Z","timestamp":1748131200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2025,5,25]],"date-time":"2025-05-25T00:00:00Z","timestamp":1748131200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Hemodialysis International"],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Home hemodialysis (home HD) continues to be an underutilized dialysis modality despite its potential advantages when compared to peritoneal dialysis (PD) and in\u2010center hemodialysis (HD).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      We conducted a retrospective study to evaluate the feasibility of using the B. Braun Dialog+ HD machine to provide home HD with the necessary requirements and modifications at home to be able to provide such treatments. In this retrospective study, we compared data obtained from patients who received home HD using the B. Braun Dialog+ HD machine since we started utilizing it for home HD (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200927 patients) to data obtained from eligible patients who received home HD using the NxStage System One machine around the same period (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200936 patients).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Our results showed that the B. Braun group had a better single treatment single\u2010pool Kt\/V (spKt\/V) (1.48\u2009\u00b1\u20090.27 for B. Braun vs. 1.14\u2009\u00b1\u20090.32 for NxStage,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001), better standard weekly Kt\/V (4.44\u2009\u00b1\u20090.82 for B. Braun vs. 2.65\u2009\u00b1\u20090.57 for NxStage,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001), and better urea reduction rate (URR) (71.4\u2009\u00b1\u20096.2 for B. Braun vs. 59.2\u2009\u00b1\u20099.1 for NxStage,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). The duration for the HD treatments among the B. Braun group patients was significantly shorter than that of the NxStage group patients (3.48\u2009\u00b1\u20090.32 vs. 4.58\u2009\u00b1\u20091.52,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001) while the ultrafiltration rate for the B. Braun group patients was significantly larger than that of the NxStage group patients (1.83\u2009\u00b1\u20090.64 vs. 1.18\u2009\u00b1\u20090.66,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). The average laboratory data for both groups showed that there was only a significant difference between the two groups in bicarbonate level, with B. Braun having a lower level (23.5\u2009\u00b1\u20092.0 for B. Braun vs. 24.9\u2009\u00b1\u20092.8 for NxStage,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.021). There were no significant differences between the two groups in the average albumin, BUN, calcium, creatinine, hemoglobin, phosphorus, platelets, potassium, WBC, or PTH.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>B. Braun HD machine is another HD device that can be considered to provide home HD. Our study has shown that B. Braun machine had higher spKt\/V in addition to standard weekly Kt\/V and URR when compared to the NxStage machine. Larger, well\u2010designed, and well\u2010powered studies are needed to confirm these results.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/hdi.13254","type":"journal-article","created":{"date-parts":[[2025,5,25]],"date-time":"2025-05-25T23:38:27Z","timestamp":1748216307000},"page":"507-512","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Use of the B. Braun Hemodialysis Machine to Provide Home Hemodialysis"],"prefix":"10.1111","volume":"29","author":[{"given":"Rachid","family":"Daoui","sequence":"first","affiliation":[{"name":"Saratoga Hospital  Saratoga Springs New York USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul","family":"Feustel","sequence":"additional","affiliation":[{"name":"Albany Medical College  Albany New York USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christina","family":"Manning","sequence":"additional","affiliation":[{"name":"Albany Medical College  Albany New York USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1460-0536","authenticated-orcid":false,"given":"Loay","family":"Salman","sequence":"additional","affiliation":[{"name":"Albany Medical College  Albany New York USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,5,25]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.34067\/KID.0000000000000360"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1159\/000485159"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ackd.2020.09.002"},{"key":"e_1_2_10_5_1","unstructured":"Quanta Dialysis Technologies \u201cQuanta Dialysis System Receives FDA Clearance for Home Hemodialysis \u201d2024 https:\/\/www.prnewswire.com\/news\u2010releases\/quanta\u2010dialysis\u2010system\u2010receives\u2010fda\u2010clearance\u2010for\u2010home\u2010hemodialysis\u2010302295281.html."},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2015.07.015"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0272-6386(03)00531-6"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1681\/ASN.2015040426"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1001593"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2021.01.025"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2018.09.015"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12882-023-03264-5"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2022.02.001"},{"key":"e_1_2_10_14_1","unstructured":"U.S. Department of Health and Human Services \u201cAdvancing American Kidney Health \u201d2019 https:\/\/aspe.hhs.gov\/sites\/default\/files\/private\/pdf\/262046\/AdvancingAmericanKidneyHealth.pdf."},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/sdi.12939"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm11144166"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ackd.2021.02.008"},{"issue":"1","key":"e_1_2_10_18_1","first-page":"S8","article-title":"The Home Hemodialysis Hub: Physical Infrastructure and Integrated Governance Structure","volume":"19","author":"Marshall M. R.","year":"2015","journal-title":"Hemodialysis International"},{"issue":"1","key":"e_1_2_10_19_1","first-page":"S71","article-title":"Patient Selection and Training for Home Hemodialysis","volume":"19","author":"Rioux J. P.","year":"2015","journal-title":"Hemodialysis International"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.2147\/CEOR.S69340"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ackd.2021.02.007"}],"container-title":["Hemodialysis International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/hdi.13254","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/hdi.13254","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/hdi.13254","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T01:30:41Z","timestamp":1773192641000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/hdi.13254"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,25]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,10]]}},"alternative-id":["10.1111\/hdi.13254"],"URL":"https:\/\/doi.org\/10.1111\/hdi.13254","archive":["Portico"],"relation":{},"ISSN":["1492-7535","1542-4758"],"issn-type":[{"value":"1492-7535","type":"print"},{"value":"1542-4758","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,25]]},"assertion":[{"value":"2025-02-04","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-06","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-25","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}