{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T07:50:49Z","timestamp":1740124249507,"version":"3.37.3"},"reference-count":26,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2017,8,6]],"date-time":"2017-08-06T00:00:00Z","timestamp":1501977600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"JMC Scientific Consulting Ltd"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Intern J of Cosmetic Sci"],"published-print":{"date-parts":[[2017,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Objective<\/jats:title><jats:p>Methods which assess skin moisturization based on changes in its electrical properties are widely used in both cosmetic and medical research industries. However, the devices themselves often give results which are significantly different to each other. Recently two\u2010dimensional imaging moisturization systems have become commercially available, which have the capability to provide a more detailed assessment of what is contributing to measured skin moisturization. Presented here is a new <jats:italic>in vitro<\/jats:italic> method for preparing textured model test substrates for use with these devices, and results of their use to provide a clearer insight into the devices operation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>A variety of different textured model test substrates were measured using a commercially available skin moisturization measurement device, the Epsilon. The response of the Epsilon was also tested against conventional skin moisturization devices.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Surface morphology of model test substrates was found to have a significant influence on the measurement of its electrical properties with both the conventional and two\u2010dimensional skin moisturization measurement devices. Through modification of the areas of the image being assessed for the two\u2010dimensional moisturization mapping device, the parts of the model test substrate in contact with the device were indentified and analysed separately to areas not in contact with the sensor. This provided a more robust assessment of the electrical properties of substrate itself, rather than being influenced by texture like the conventional skin moisturization measurement devices.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>While the two\u2010dimensional moisturization mapping systems can be used like a conventional electrical skin measurement device giving a simple overall reading of skin moisturization for the test area, their true value over existing electrical measures comes from its ability to isolate the skin itself from areas which are not in contact with the sensor.<\/jats:p><\/jats:sec>","DOI":"10.1111\/ics.12410","type":"journal-article","created":{"date-parts":[[2017,7,12]],"date-time":"2017-07-12T06:56:39Z","timestamp":1499842599000},"page":"572-578","source":"Crossref","is-referenced-by-count":5,"title":["Understanding the effects of topography on skin moisturization measurement via two\u2010dimensional capacitance imaging"],"prefix":"10.1111","volume":"39","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2549-396X","authenticated-orcid":false,"given":"J. M.","family":"Crowther","sequence":"first","affiliation":[{"name":"JMC Scientific Consulting Ltd Egham Surrey TW20 8LL UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2017,8,6]]},"reference":[{"key":"e_1_2_6_2_1","first-page":"3","volume-title":"Handbook of non\u2010invasive methods and the skin","author":"Kligmann A.M","year":"1995"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-662-08585-1"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1038\/jid.1952.52"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-2275(20)38361-9"},{"key":"e_1_2_6_6_1","first-page":"284","article-title":"Assessment of skin moisture","volume":"68","author":"Blichmann C.W.","year":"1988","journal-title":"Acta Derm. Venereol. (Stockh.)"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0846.2006.00200.x"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/srt.12257"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0846.1999.tb00127.x"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0846.2004.00050.x"},{"key":"e_1_2_6_11_1","first-page":"33","article-title":"Skin hydration assessment through modern non\u2010invasive bioengineering technologies","volume":"9","author":"Constantin M.\u2010M.","year":"2014","journal-title":"Maedica"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/ics.12180"},{"key":"e_1_2_6_13_1","first-page":"193","article-title":"Effects of seaweed Laminaria japonica extracts on skin moisturizing activity in vivo","volume":"64","author":"Choi J.S.","year":"2013","journal-title":"J. Cosmet. Sci."},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/ics.12324"},{"key":"e_1_2_6_15_1","first-page":"500","article-title":"Skin capacitance imaging, a new technique for investigating the skins surface","volume":"16","author":"L\u00e9v\u00eaque J.L.","year":"2006","journal-title":"Eur. J. Dermatol."},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0846.2012.00637.x"},{"key":"e_1_2_6_17_1","unstructured":"Courage and Khazaka MoistureMap MM100 device. Available at:http:\/\/www.courage-khazaka.de\/index.php\/en\/news\/scientific-news\/284-news-moisturemap-e accessed 25 March 2017."},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1467-2494.2002.00146.x"},{"key":"e_1_2_6_19_1","doi-asserted-by":"crossref","first-page":"245","DOI":"10.2340\/0001555570245247","article-title":"The relationship between electrical capacitance and the mechanical properties of human skin in vivo","volume":"70","author":"Jemec G.B.E.","year":"1990","journal-title":"Acta Derm. Venereol. (Stockh.)"},{"key":"e_1_2_6_20_1","unstructured":"Information taken from Courage and Khazaka manual for Corneometer CM825\u00ae."},{"key":"e_1_2_6_21_1","doi-asserted-by":"crossref","first-page":"245","DOI":"10.2340\/0001555570245247","article-title":"The relationship between electrical capacitance and the mechanical properties of human skin in vivo","volume":"70","author":"Jemec G.B.E.","year":"1990","journal-title":"Acta Derm. Venereol. (Stockh.)"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/0923-1811(91)90021-O"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-4632.2007.03455.x"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/ics.12209"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2013.2264879"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0846.2011.00516.x"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-68682-5_35"}],"container-title":["International Journal of Cosmetic Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fics.12410","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ics.12410","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,3]],"date-time":"2023-10-03T22:57:26Z","timestamp":1696373846000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/ics.12410"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8,6]]},"references-count":26,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2017,10]]}},"alternative-id":["10.1111\/ics.12410"],"URL":"https:\/\/doi.org\/10.1111\/ics.12410","archive":["Portico"],"relation":{},"ISSN":["0142-5463","1468-2494"],"issn-type":[{"type":"print","value":"0142-5463"},{"type":"electronic","value":"1468-2494"}],"subject":[],"published":{"date-parts":[[2017,8,6]]}}}