{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T22:43:24Z","timestamp":1783032204340,"version":"3.54.6"},"reference-count":18,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2023,9,20]],"date-time":"2023-09-20T00:00:00Z","timestamp":1695168000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Int J Lab Hematology"],"published-print":{"date-parts":[[2024,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Introduction<\/jats:title><jats:p>The Atellica Hema (Siemens Healthineers, Tarrytown, NY, USA) is a new generation multi\u2010parameter analyzer for full blood count, 6\u2010part differential and reticulocyte testing by impedance variation and fluorescence flow cytometry. In this study, we verified the whole blood and limited body fluid modes of the Atellica Hema 580.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>We evaluated precision, linearity, carry\u2010over, throughput and performed a method comparison to assess the performance of the Atellica Hema 580. For comparison of the Atellica Hema 580 with the Sysmex XN\u20101000 (Sysmex, Kobe, Japan), 140 samples from adult and pediatric patients including both normal and abnormal hematology profiles were analyzed in parallel.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The Atellica Hema 580 demonstrated acceptable imprecision within the manufacturer's specifications for whole blood and body fluid modes, good linearity for high and low ranges and no significant carryover. The full blood count, differential and reticulocyte correlated well with the Sysmex XN\u20101000, except for mean cell hemoglobin concentration, basophil and large immature cells. The optical platelet count, reflexed in 34 samples with a platelet count &lt;150 \u00d7\u200910<jats:sup>9<\/jats:sup>\/l, showed a strong correlation with the fluorescent platelet count on the Sysmex XN\u20101000. The morphology flagging efficiency was 92% for white blood cells, 95% for red blood cells and 87% for platelets.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The Atellica Hema 580 showed good analytical performance and workflow efficiency for a wide range of patient samples.<\/jats:p><\/jats:sec>","DOI":"10.1111\/ijlh.14170","type":"journal-article","created":{"date-parts":[[2023,9,21]],"date-time":"2023-09-21T01:46:50Z","timestamp":1695260810000},"page":"63-71","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Performance evaluation the new automated Atellica Hema 580 hematology analyzer"],"prefix":"10.1111","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1534-2930","authenticated-orcid":false,"given":"E.","family":"Schapkaitz","sequence":"first","affiliation":[{"name":"Department of Molecular Medicine and Hematology University of Witwatersrand Medical School  Johannesburg South Africa"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Baiden","sequence":"additional","affiliation":[{"name":"Department of Molecular Medicine and Hematology University of Witwatersrand Medical School  Johannesburg South Africa"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Raburabu","sequence":"additional","affiliation":[{"name":"Department of Molecular Medicine and Hematology National Health Laboratory Service  Johannesburg South Africa"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2023,9,20]]},"reference":[{"key":"e_1_2_9_2_1","volume-title":"Atellica\u2010Hema 580 Analyzer Operators Guide","year":"2021"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/ijlh.12201"},{"key":"e_1_2_9_4_1","first-page":"106","volume-title":"EP15\u2010A3: User Verification of Precision and Estimatio of Bias. CLSI Document EP15\u2010A3","author":"CLSI","year":"2014"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/ijlh.12196"},{"key":"e_1_2_9_6_1","first-page":"116","volume-title":"Measurement Procedure Comparison and Bias Estimation Using Patient Samples","author":"CLSI","year":"2018"},{"key":"e_1_2_9_7_1","volume-title":"H26\u2010A2: Validation, Verification, and Quality Assurance of Automated Hematology Analysers","author":"CLSI","year":"2010"},{"key":"e_1_2_9_8_1","unstructured":"AarsandA.The EFLM Biological Variation Database. Accessed 21 February 2023.https:\/\/biologicalvariation.eu\/"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/ijlh.12503"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1532\/LH96.05019"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiochem"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/ijlh.12254"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/ijlh.13082"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/ijlh.13020"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/ijlh.12164"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0217298"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1309\/ajcpuaggb4url5xo"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.21037\/atm\u201021\u2010691"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/ijlh.13396"}],"container-title":["International Journal of Laboratory Hematology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ijlh.14170","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,31]],"date-time":"2024-10-31T09:46:21Z","timestamp":1730367981000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/ijlh.14170"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,20]]},"references-count":18,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,2]]}},"alternative-id":["10.1111\/ijlh.14170"],"URL":"https:\/\/doi.org\/10.1111\/ijlh.14170","archive":["Portico"],"relation":{},"ISSN":["1751-5521","1751-553X"],"issn-type":[{"value":"1751-5521","type":"print"},{"value":"1751-553X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,20]]},"assertion":[{"value":"2023-06-22","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-08-29","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-09-20","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}