{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,22]],"date-time":"2026-02-22T05:53:16Z","timestamp":1771739596738,"version":"3.50.1"},"reference-count":38,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2025,5,10]],"date-time":"2025-05-10T00:00:00Z","timestamp":1746835200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Int J Lab Hematology"],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:sec><jats:title>Introduction<\/jats:title><jats:p>This study aimed to evaluate the analytical and diagnostic performance of the HemoCue 201 device by comparing venous EDTA, venous heparinized, and capillary blood samples.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The HemoCue 201 device was compared with an automated analyzer. Hemoglobin levels were measured from EDTA, heparinized, and capillary blood samples. Analytical performance was assessed using mean\u2009\u00b1\u2009SD, paired <jats:italic>t<\/jats:italic>\u2010test, intraclass correlation coefficient (ICC), and Bland\u2013Altman plots. The CLIA 2025 criteria for acceptable error were applied to determine agreement. Diagnostic performance was determined via sensitivity, specificity, diagnostic effectiveness, positive predictive value (PPV), negative predictive value (NPV), and likelihood ratios.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The results showed excellent reliability with ICC values of 1.00 for both EDTA and heparinized, and 0.97 for capillary blood. Bland\u2013Altman plots indicated small biases for EDTA (0.08 [\u22120.27 to 0.42]) and heparin (0.09 [\u22120.40 to 0.57]), but larger negative biases for capillary blood (\u22120.12 [\u22121.21 to 0.97]). According to CLIA 2025 criteria, 98% of EDTA and 95% of heparin samples were within the \u00b14% cut\u2010off, whereas only 68% of capillary samples met this criterion. Diagnostic performance demonstrated strong potential as a rapid and reliable anemia screening tool due to its high sensitivity (100%) and NPV (100%).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The HemoCue 201 device reliably measured hemoglobin and detected anemia in all sample types. Heparinized blood, commonly used in point\u2010of\u2010care blood gas tests, can effectively support hemoglobin testing, reducing the need for additional blood draws. However, capillary samples exhibited greater bias, with variability influenced by pre\u2010analytical factors. Standardized protocol and manufacturer guidelines helped minimize analytical variation.<\/jats:p><\/jats:sec>","DOI":"10.1111\/ijlh.14495","type":"journal-article","created":{"date-parts":[[2025,5,10]],"date-time":"2025-05-10T08:24:02Z","timestamp":1746865442000},"page":"817-825","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Evaluation of <scp>HemoCue<\/scp> 201 Performance for Hemoglobin Measurement and Anemia Detection in <scp>EDTA<\/scp>, Heparinized, and Capillary Blood Samples"],"prefix":"10.1111","volume":"47","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-1790-9841","authenticated-orcid":false,"given":"Orakan","family":"Limpornpugdee","sequence":"first","affiliation":[{"name":"Department of Laboratory Medicine Faculty of Medicine, Chulalongkorn University  Bangkok Thailand"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sithee","family":"Sodmanee","sequence":"additional","affiliation":[{"name":"Division of Laboratory Medicine King Chulalongkorn Memorial Hospital  Bangkok Thailand"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Panatda","family":"Sohab","sequence":"additional","affiliation":[{"name":"Division of Laboratory Medicine King Chulalongkorn Memorial Hospital  Bangkok Thailand"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chitnuphong","family":"Saengnil","sequence":"additional","affiliation":[{"name":"Division of Laboratory Medicine King Chulalongkorn Memorial Hospital  Bangkok Thailand"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7844-4854","authenticated-orcid":false,"given":"Narisorn","family":"Kongruttanachok","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine Faculty of Medicine, Chulalongkorn University  Bangkok Thailand"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,5,10]]},"reference":[{"key":"e_1_2_12_2_1","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.55315"},{"key":"e_1_2_12_3_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0152184"},{"key":"e_1_2_12_4_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12871\u2010019\u20100916\u20102"},{"key":"e_1_2_12_5_1","doi-asserted-by":"publisher","DOI":"10.1213\/ANE.0000000000004533"},{"key":"e_1_2_12_6_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.jvca.2015.11.010"},{"key":"e_1_2_12_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tacc.2019.12.003"},{"key":"e_1_2_12_8_1","doi-asserted-by":"publisher","DOI":"10.2147\/JBM.S103788"},{"key":"e_1_2_12_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537\u20102995.2009.02134.x"},{"key":"e_1_2_12_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0b013e318271604e"},{"key":"e_1_2_12_11_1","doi-asserted-by":"publisher","DOI":"10.4269\/ajtmh.16\u20100735"},{"key":"e_1_2_12_12_1","doi-asserted-by":"publisher","DOI":"10.52711\/0974\u2010360X.2022.00786"},{"key":"e_1_2_12_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiochem.2022.11.012"},{"key":"e_1_2_12_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.heliyon.2023.e17311"},{"key":"e_1_2_12_15_1","doi-asserted-by":"publisher","DOI":"10.4103\/0377\u20104929.91494"},{"key":"e_1_2_12_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/nyas.14124"},{"key":"e_1_2_12_17_1","doi-asserted-by":"publisher","DOI":"10.1515\/CCLM.2007.110"},{"key":"e_1_2_12_18_1","volume-title":"CLSI document H15\u2010A3","author":"CLSI","year":"2000"},{"key":"e_1_2_12_19_1","doi-asserted-by":"publisher","DOI":"10.4103\/picr.PICR_123_17"},{"key":"e_1_2_12_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcm.2016.02.012"},{"issue":"23","key":"e_1_2_12_21_1","article-title":"Clinical Laboratory Improvement Amendments of 1988 (CLIA) Proficiency Testing Regulations Related to Analytes and Acceptable Performance","volume":"84","author":"CMS","year":"2024","journal-title":"Federal Register"},{"issue":"4","key":"e_1_2_12_22_1","first-page":"203","article-title":"Measures of Diagnostic Accuracy: Basic Definitions","volume":"19","author":"\u0160imundi\u0107 A. M.","year":"2009","journal-title":"Ejifcc"},{"issue":"4","key":"e_1_2_12_23_1","first-page":"170","article-title":"Evidence Based Emergency Medicine Part 3: Positive and Negative Likelihood Ratios of Diagnostic Tests","volume":"3","author":"Baratloo A.","year":"2015","journal-title":"Emerg (Tehran)"},{"key":"e_1_2_12_24_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.329.7458.168"},{"key":"e_1_2_12_25_1","unstructured":"WHO \u201cHaemoglobin Concentrations for the Diagnosis of Anaemia and Assessment of Severity \u201dVitamin and Mineral Nutrition Information System (2022) https:\/\/www.who.int\/publications\/i\/item\/WHO\u2010NMH\u2010NHD\u2010MNM\u201011.1."},{"key":"e_1_2_12_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/S2352\u20103026(23)00160\u20106"},{"key":"e_1_2_12_27_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12871\u2010020\u201001008\u20108"},{"issue":"1","key":"e_1_2_12_28_1","first-page":"78","article-title":"Reliability of Heparinized Blood Samples in Point\u2010Of\u2010Care Hemoglobin Analysis","volume":"21","author":"Thompson S.","year":"2021","journal-title":"BMC Hematology"},{"key":"e_1_2_12_29_1","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X9202000419"},{"key":"e_1_2_12_30_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365\u20102257.2001.00388.x"},{"issue":"4","key":"e_1_2_12_31_1","first-page":"295","article-title":"Influence of Pre\u2010Analytical Variables on Capillary Blood Hemoglobin Measurement","volume":"73","author":"Smith J.","year":"2020","journal-title":"Journal of Clinical Pathology"},{"key":"e_1_2_12_32_1","doi-asserted-by":"publisher","DOI":"10.1136\/jclinpath\u20102021\u2010207602"},{"issue":"10","key":"e_1_2_12_33_1","first-page":"1525","article-title":"Standardizing Capillary Blood Collection Techniques to Improve Hemoglobin Measurement Accuracy","volume":"57","author":"Jones P.","year":"2019","journal-title":"CCLM"},{"key":"e_1_2_12_34_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12288\u2010019\u201001196\u20105"},{"key":"e_1_2_12_35_1","doi-asserted-by":"publisher","DOI":"10.1039\/d0lc01235a"},{"key":"e_1_2_12_36_1","doi-asserted-by":"publisher","DOI":"10.1111\/tmi.13957"},{"issue":"1","key":"e_1_2_12_37_1","first-page":"13","article-title":"Evaluation of Point\u2010Of\u2010Care Hemoglobin Analyzers in a Southeast Asian Clinical Setting","volume":"30","author":"Nguyen V.","year":"2023","journal-title":"Asian Journal of Clinical and Laboratory Science"},{"issue":"4","key":"e_1_2_12_38_1","first-page":"123","article-title":"Use of Point\u2010Of\u2010Care Devices for Hemoglobin Measurement in Resource\u2010Limited Settings","volume":"17","author":"Garcia M.","year":"2022","journal-title":"Global Health Journal"},{"issue":"3","key":"e_1_2_12_39_1","first-page":"200","article-title":"Future Perspectives on Point\u2010Of\u2010Care Hemoglobin Testing: Technological Advancements and Clinical Applications","volume":"48","author":"Miller R.","year":"2023","journal-title":"Journal of Laboratory Medicine"}],"container-title":["International Journal of Laboratory Hematology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ijlh.14495","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,12]],"date-time":"2025-09-12T20:07:27Z","timestamp":1757707647000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/ijlh.14495"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,10]]},"references-count":38,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025,10]]}},"alternative-id":["10.1111\/ijlh.14495"],"URL":"https:\/\/doi.org\/10.1111\/ijlh.14495","archive":["Portico"],"relation":{},"ISSN":["1751-5521","1751-553X"],"issn-type":[{"value":"1751-5521","type":"print"},{"value":"1751-553X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,10]]},"assertion":[{"value":"2024-11-13","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-04-28","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-10","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}