{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,11]],"date-time":"2026-10-11T09:35:36Z","timestamp":1791711336446,"version":"4.3.4"},"reference-count":17,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T00:00:00Z","timestamp":1757548800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T00:00:00Z","timestamp":1757548800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Int J Lab Hematology"],"published-print":{"date-parts":[[2026,2]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>The current reference method for the white blood cell (WBC) differential is manual smear review as outlined in CLSI H20\u2010A2. As with many manual methods, it suffers from a number of challenges including dependence upon the expertise of the interpreter, the quality of the smear and stain, when dysplastic features make cell identification difficult, imprecision with leucopenia, and enumeration bias due to non\u2010uniform cell distribution.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This study describes an alternative method for establishing the leucocyte differential using a single\u2010tube, 8\u2010color flow cytometric reference method.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Data presented is from an international comparison of normal (based on analyzer counts,\n                      <jats:italic>N<\/jats:italic>\n                      \u2009=\u2009120) and abnormal (\n                      <jats:italic>N<\/jats:italic>\n                      \u2009=\u2009496) clinical samples performed at four institutions using four different models of flow cytometers. Here we demonstrate equivalent performance between the flow cytometric method and the current manual reference method, but show improved performance of the proposed reference method for low\/infrequent cell populations, for example, monocytes and basophils.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The flow cytometric method also performs well in comparison with hematology analyzers in current clinical use, including good correlation for total white blood cell enumeration. The findings indicate that the flow cytometric method, deemed the \u201cICSH WBC reference,\u201d could be used in lieu of CLSI H20\u2010A2 as a reference for white blood cell enumeration and differential counting and specifically for the evaluation of automated differential counters.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/ijlh.14553","type":"journal-article","created":{"date-parts":[[2025,9,12]],"date-time":"2025-09-12T06:06:44Z","timestamp":1757657204000},"page":"93-101","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["White Blood Cell Enumeration and Differential by Flow Cytometry: The\n                    <scp>ICSH WBC<\/scp>\n                    Reference Method"],"prefix":"10.1111","volume":"48","author":[{"given":"Benjamin D.","family":"Hedley","sequence":"first","affiliation":[{"name":"London Health Science Center  London Ontario Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Keeney","sequence":"additional","affiliation":[{"name":"London Health Science Center  London Ontario Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Gambell","sequence":"additional","affiliation":[{"name":"Peter McCallum Cancer Center  Melbourne Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chenxue","family":"Qu","sequence":"additional","affiliation":[{"name":"Peking University First Hospital  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jenny","family":"Mao","sequence":"additional","affiliation":[{"name":"University of Washington  Seattle WA USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bruce H.","family":"Davis","sequence":"additional","affiliation":[{"name":"Trillium Diagnostics (Retired CEO)  Bangor Maine USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brent L.","family":"Wood","sequence":"additional","affiliation":[{"name":"University of Washington  Seattle WA USA"},{"name":"Children's Hospital los Angeles  Los Angeles California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,9,11]]},"reference":[{"key":"e_1_2_7_2_1","unstructured":"J. A.Koepke O. W.Van Assendelft L. J.Brindza et\u00a0al. \u201cReference Leukocyte (WBC) Differential Count (Proportional) and Evaluation of Instrumental Methods; Approved Standard\u2014Second Edition. CLSI Document H20\u2010A2 \u201d2007Wayne PA: Clinical Laboratory Standards Institute."},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1002\/jcla.23827"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1002\/cyto.a.20457"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1002\/cyto.a.20893"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1515\/cclm\u20102018\u20101356"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/cyto.a.21105"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/cyto.b.20382"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-0320(19970415)30:2<72::AID-CYTO2>3.0.CO;2-F"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/ijlh.12607"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/cyto.a.22092"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/cpz1.383"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/cyto.b.10024"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1182\/blood.V108.11.3839.3839"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1309\/LMF0OBUBPMWPOKS1"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.3343\/alm.2015.35.1.28"},{"issue":"30","key":"e_1_2_7_17_1","first-page":"2392","article-title":"Clinical Evaluation of Leukocyte Differential Count in Peripheral Blood by Five\u2010Color Flow Cytometry","volume":"93","author":"Xing Y.","year":"2013","journal-title":"Zhonghua Yi Xue Za Zhi"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/ijlh.13764"}],"container-title":["International Journal of Laboratory Hematology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ijlh.14553","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/ijlh.14553","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ijlh.14553","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,31]],"date-time":"2026-01-31T10:09:46Z","timestamp":1769854186000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/ijlh.14553"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,11]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,2]]}},"alternative-id":["10.1111\/ijlh.14553"],"URL":"https:\/\/doi.org\/10.1111\/ijlh.14553","archive":["Portico"],"relation":{},"ISSN":["1751-5521","1751-553X"],"issn-type":[{"value":"1751-5521","type":"print"},{"value":"1751-553X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,11]]},"assertion":[{"value":"2025-02-04","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-08-29","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-11","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}