{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T04:46:10Z","timestamp":1784263570837,"version":"3.55.0"},"reference-count":24,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T00:00:00Z","timestamp":1758844800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T00:00:00Z","timestamp":1758844800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Int J Lab Hematology"],"published-print":{"date-parts":[[2026,2]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Thrombotic thrombocytopenic purpura (TTP) is a rare but life\u2010threatening thrombotic microangiopathy characterized by a severe deficiency of ADAMTS13 activity, typically defined as less than 10\u2009IU\/dL. Rapid and reliable measurement of ADAMTS13 activity is crucial for both timely diagnosis and effective long\u2010term patient monitoring. While ELISA\u2010based methods are widely used, automated assays offer potential advantages in terms of turnaround time and standardization. This study evaluates two automated ADAMTS13 activity assays, HemosIL AcuStar ADAMTS13 Activity Assay (Werfen) and TECHNOFLUOR ADAMTS13 Activity (Technoclone), in comparison to the TECHNOZYM ADAMTS13 Activity ELISA (Technoclone).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>ADAMTS13 activity was measured in 100 patient samples using three assays: TECHNOZYM ADAMTS13 Activity ELISA, HemosIL AcuStar ADAMTS13 Activity, and TECHNOFLUOR ADAMTS13 Activity. Analytical performance and method comparison were assessed. Additionally, calibration against the WHO standard was evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Both automated assays demonstrated high precision, with lower coefficients of variation (CV) compared to the ELISA. The HemosIL assay showed CVs ranging from 4.6% to 7.1%, while the TECHNOFLUOR assay exhibited CVs between 3.0% and 3.3%. ADAMTS13 activity measurements obtained with ELISA were significantly higher than those from both automated assays, which showed no statistically significant difference between them. Both automated assays achieved a sensitivity of 100%, with one false\u2010positive TTP classification. The HemosIL assay showed the greatest bias between WHO and manufacturer\u2010based calibrations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The automated systems exhibit strong performance and rapid turnaround times, making them well\u2010suited for routine ADAMTS13 determination. Standardization and calibration against international benchmarks, such as the WHO standard, is essential to minimize inter\u2010assay variability and ensure reliable clinical interpretation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/ijlh.70004","type":"journal-article","created":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T07:32:41Z","timestamp":1758871961000},"page":"194-201","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["<scp>ADAMTS13<\/scp>\n                    Activity Testing: Evaluation of Two Automated Platforms for Diagnosis and Follow\u2010Up of Thrombotic Thrombocytopenic Purpura"],"prefix":"10.1111","volume":"48","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-0360-1556","authenticated-orcid":false,"given":"Margot","family":"Cornette","sequence":"first","affiliation":[{"name":"Coagulation Laboratory, Department of Laboratory Medicine University Hospital Ghent  Ghent Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7559-2579","authenticated-orcid":false,"given":"Katrien M. J.","family":"Devreese","sequence":"additional","affiliation":[{"name":"Coagulation Laboratory, Department of Laboratory Medicine University Hospital Ghent  Ghent Belgium"},{"name":"Department of Diagnostic Sciences Ghent University  Ghent Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,9,26]]},"reference":[{"key":"e_1_2_12_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/jth.15006"},{"key":"e_1_2_12_3_1","doi-asserted-by":"publisher","DOI":"10.3390\/ijms25158137"},{"key":"e_1_2_12_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/ijlh.13295"},{"key":"e_1_2_12_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/jth.12881"},{"key":"e_1_2_12_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365\u20102141.2005.05420.x"},{"key":"e_1_2_12_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/rth2.12461"},{"key":"e_1_2_12_8_1","doi-asserted-by":"publisher","DOI":"10.1055\/s\u20100038\u20101641151"},{"key":"e_1_2_12_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/ijlh.12718"},{"key":"e_1_2_12_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/ijlh.13414"},{"key":"e_1_2_12_11_1","doi-asserted-by":"publisher","DOI":"10.1160\/TH12\u201008\u20100565"},{"key":"e_1_2_12_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/ijlh.12542"},{"key":"e_1_2_12_13_1","doi-asserted-by":"publisher","DOI":"10.1515\/cclm\u20102020\u20101020"},{"key":"e_1_2_12_14_1","unstructured":"Werfen Instrumentation Laboratory Launches HemosIL AcuStar ADAMTS13 Activity Assay in Europe and Other International Markets(2019) https:\/\/www.werfen.com\/na\/en\/instrumentation\u2010laboratory\u2010launches\u2010hemosil\u2010acustar\u2010adamts13\u2010activity\u2010assay\u2010europe\u2010and\u2010other."},{"key":"e_1_2_12_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/ijlh.14090"},{"key":"e_1_2_12_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/jth.15157"},{"key":"e_1_2_12_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.rpth.2023.100108"},{"key":"e_1_2_12_18_1","doi-asserted-by":"publisher","DOI":"10.1055\/s\u20100039\u20101696718"},{"key":"e_1_2_12_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11239\u2010020\u201002086\u20108"},{"key":"e_1_2_12_20_1","doi-asserted-by":"publisher","DOI":"10.26442\/00403660.2020.12.200508"},{"key":"e_1_2_12_21_1","unstructured":"Technoclone https:\/\/www.technoclone.com\/en\/instruments\/ceveron\u2010s100."},{"key":"e_1_2_12_22_1","unstructured":"E.Union Regulation (EU) 2017\/746 of the European Parliament and of the Council of 5 April 2017 on In\u00a0Vitro Diagnostic Medical Devices and REPEALING DIRECTIVE 98\/79\/EC and Commission Decision 2010\/227\/EU(2017) https:\/\/eur\u2010lex.europa.eu\/eli\/reg\/2017\/746\/oj\/eng."},{"key":"e_1_2_12_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtha.2025.02.038"},{"key":"e_1_2_12_24_1","unstructured":"Clinical and Laboratory Standards Institute EP17\u2010A: Protocols for Determination of Limits of Detection and Limits of Quantitation."},{"key":"e_1_2_12_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/jth.13571"}],"container-title":["International Journal of Laboratory Hematology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ijlh.70004","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/ijlh.70004","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ijlh.70004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,31]],"date-time":"2026-01-31T10:09:36Z","timestamp":1769854176000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/ijlh.70004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,26]]},"references-count":24,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,2]]}},"alternative-id":["10.1111\/ijlh.70004"],"URL":"https:\/\/doi.org\/10.1111\/ijlh.70004","archive":["Portico"],"relation":{},"ISSN":["1751-5521","1751-553X"],"issn-type":[{"value":"1751-5521","type":"print"},{"value":"1751-553X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,26]]},"assertion":[{"value":"2025-05-13","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-10","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-26","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}