{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,19]],"date-time":"2026-11-19T16:58:20Z","timestamp":1795107500605,"version":"4.10.3"},"reference-count":52,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T00:00:00Z","timestamp":1761782400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T00:00:00Z","timestamp":1761782400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Int J of Nursing Practice"],"published-print":{"date-parts":[[2025,12]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Point\u2010of\u2010care ultrasound (POCUS) is used to verify the position of the nasogastric tube as an alternative to conventional methods.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Aim<\/jats:title>\n                    <jats:p>This study aims to determine the diagnostic accuracy of POCUS in detecting nasogastric tube placement in emergency patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This was a prospective diagnostic accuracy study conducted at an emergency department between August and November 2021. We included 72 consecutively recruited patients aged 18\u2009years and older who were planned for nasogastric tube insertion. The index and reference tests were ultrasound and chest X\u2010ray, respectively. Nasogastric tube placement was detected by ultrasound and X\u2010ray methods in all patients. Sensitivity, specificity and predictive values were calculated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Seventy\u2010two patients (mean age: 69.49\u2009\u00b1\u200913.75, 55.6% male) were included. According to neck and gastric ultrasound, 58 nasogastric tubes (80.6%) could be detected. When POCUS was compared to X\u2010rays, 56 (84.9%) were true positive and two (33.3%) were false positive. Fourteen nasogastric tubes (19.4%) could not be detected. When POCUS was compared to X\u2010rays, four (66.7%) were true negative and 10 (15.1%) were false negative. A combination of neck and gastric ultrasound had a sensitivity of 84.84% (95% CI, 73.9%\u201392.49%), a specificity of 66.6% (95% CI, 22.28%\u201395.67%), a positive predictive value of 96.55% (95% CI, 89.99%\u201398.87%) and a negative predictive value of 28.57% (95% CI, 15.19%\u201347.19%). The percentage agreement was high (0.83%), and Gwet's AC1 statistic rated as moderate (AC1\u2009=\u20090.46).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>POCUS can be used as a diagnostic tool in detecting nasogastric tube placement in the stomach but should be confirmed with a chest X\u2010ray in patients with a negative ultrasound result.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/ijn.70077","type":"journal-article","created":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T07:09:02Z","timestamp":1761894542000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Diagnostic Accuracy of Point\u2010of\u2010Care Ultrasound in Detecting Nasogastric Tube Placement in Emergency Patients"],"prefix":"10.1111","volume":"31","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6886-7781","authenticated-orcid":false,"given":"Kemal","family":"Yilmaz","sequence":"first","affiliation":[{"name":"Department of Internal Medicine Ege University Hospital  \u0130zmir Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9152-3469","authenticated-orcid":false,"given":"Elif\u00a0G\u00fcnay","family":"\u0130smailo\u011flu","sequence":"additional","affiliation":[{"name":"Faculty of Health Sciences, Department of Nursing Izmir Bakircay University  \u0130zmir Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2455-8044","authenticated-orcid":false,"given":"Funda\u00a0Karbek","family":"Akarca","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Department of Emergency Medicine Ege University  \u0130zmir Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,10,30]]},"reference":[{"issue":"2","key":"e_1_2_10_2_1","article-title":"Initial and Ongoing Verification of Feeding Tube Placement in Adults (Applies to Blind Insertions and Placements With an Electromagnetic Device)","volume":"36","author":"AACN Practice alert","year":"2016","journal-title":"Critical Care Nurse"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.21608\/ejchem.2024.297100.9851"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1177\/0884533616639401"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2012.02.004"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijnurstu.2014.03.004"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13049\u2010018\u20100518\u2010x"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1177\/0148607116673053"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.nurpra.2017.12.002"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clnu.2017.09.003"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.5455\/annalsmedres.2020.06.639"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/PEC.0000000000002134"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.4236\/ojn.2020.1010065"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jen.2017.07.009"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jen.2019.03.011"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.iccn.2016.08.005"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1177\/2010105817705141"},{"key":"e_1_2_10_18_1","doi-asserted-by":"crossref","DOI":"10.1590\/1983-1447.2022.20220211.en","article-title":"Bedside Ultrasonography for the Confirmation of Nasogastric Tube Placement: Agreement Between Nurse and Physician","volume":"43","author":"Ferraboli S. F.","year":"2022","journal-title":"Revista Ga\u00facha de Enfermagem"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0241849"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1177\/0884533614567714"},{"key":"e_1_2_10_21_1","volume-title":"Handbook of Inter\u2010Rater Reliability: The Definitive Guide to Measuring the Extent of Agreement Among Raters","author":"Gwet K. L.","year":"2014"},{"key":"e_1_2_10_22_1","first-page":"791","volume-title":"Nursing Principles, Nursing Science and Art","author":"Horasan H.","year":"2019"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1017\/S1049023X22000644"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.40519"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1186\/1757\u20107241\u201020\u201038"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijnurstu.2017.03.005"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.12968\/bjcn.2020.25.7.328"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-319-63143-1_21"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.11613\/BM.2012.031"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.aucc.2021.03.006"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrtlng.2019.01.003"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijnurstu.2016.06.011"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1002\/jcu.22958"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.chest.2021.01.058"},{"key":"e_1_2_10_35_1","unstructured":"National Health Service (NHS) Improvement.2016. \u201cResource Set: Initial Placement Checks for Nasogastric and Orogastric Tubes; July; 2016.\u201d Accessed May 20 2024.https:\/\/improvement.nhs.uk\/documents\/193\/Resource_set_Initial_placement_checks_for_NG_tubes_1.pdf."},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen\u20102017\u2010018128"},{"key":"e_1_2_10_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.profnurs.2024.06.007"},{"key":"e_1_2_10_38_1","doi-asserted-by":"publisher","DOI":"10.1097\/JXX.0000000000000022"},{"issue":"6","key":"e_1_2_10_39_1","first-page":"33","article-title":"Point\u2010of\u2010Care Ultrasound: A Practical Guide for Primary Care","volume":"27","author":"Shen\u2010Wagner J.","year":"2020","journal-title":"Family Practice Management"},{"key":"e_1_2_10_40_1","doi-asserted-by":"publisher","DOI":"10.1002\/jcu.23619"},{"key":"e_1_2_10_41_1","doi-asserted-by":"publisher","DOI":"10.1111\/ijn.13049"},{"key":"e_1_2_10_42_1","doi-asserted-by":"publisher","DOI":"10.12968\/bjon.2014.23.7.352"},{"key":"e_1_2_10_43_1","doi-asserted-by":"publisher","DOI":"10.12968\/bjon.2014.23.12.641"},{"key":"e_1_2_10_44_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330\u2010020\u201007302\u2010w"},{"key":"e_1_2_10_45_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.colegn.2020.10.002"},{"key":"e_1_2_10_46_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.chest.2021.02.014"},{"key":"e_1_2_10_47_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.auec.2018.09.003"},{"issue":"4","key":"e_1_2_10_48_1","first-page":"1","article-title":"Data Snapshot: Complications Linked to Iatrogenic Enteral Feeding Tube Misplacements","volume":"14","author":"Wallace S. C.","year":"2017","journal-title":"Pennsylvania Patient Safety Advisory"},{"issue":"11","key":"e_1_2_10_49_1","first-page":"3919","article-title":"Application of Point\u2010Of\u2010Care Ultrasound in Patients Receiving Enteral Nutrition","volume":"26","author":"Wang H. Y.","year":"2022","journal-title":"European Review for Medical and Pharmacological Sciences"},{"key":"e_1_2_10_50_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13089\u2010020\u201000167\u20106"},{"key":"e_1_2_10_51_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12912\u2010023\u201001183\u20102"},{"key":"e_1_2_10_52_1","doi-asserted-by":"publisher","DOI":"10.1155\/2018\/2370426"},{"key":"e_1_2_10_53_1","doi-asserted-by":"publisher","DOI":"10.1007\/s40477\u2010016\u20100219\u20100"}],"container-title":["International Journal of Nursing Practice"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ijn.70077","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/ijn.70077","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ijn.70077","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T23:55:01Z","timestamp":1792626901000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/ijn.70077"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,30]]},"references-count":52,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,12]]}},"alternative-id":["10.1111\/ijn.70077"],"URL":"https:\/\/doi.org\/10.1111\/ijn.70077","archive":["Portico"],"relation":{},"ISSN":["1322-7114","1440-172X"],"issn-type":[{"value":"1322-7114","type":"print"},{"value":"1440-172X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,30]]},"assertion":[{"value":"2023-03-16","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-09","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-30","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70077"}}