{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T12:58:52Z","timestamp":1790859532017,"version":"4.1.0"},"reference-count":36,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2016,7,20]],"date-time":"2016-07-20T00:00:00Z","timestamp":1468972800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1"},{"start":{"date-parts":[[2016,7,20]],"date-time":"2016-07-20T00:00:00Z","timestamp":1468972800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000125","name":"National Institute for Occupational Safety and Health","doi-asserted-by":"publisher","award":["OH010662"],"award-info":[{"award-number":["OH010662"]}],"id":[{"id":"10.13039\/100000125","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000066","name":"National Institute of Environmental Health Sciences","doi-asserted-by":"publisher","award":["ES024719"],"award-info":[{"award-number":["ES024719"]}],"id":[{"id":"10.13039\/100000066","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Indoor Air"],"published-print":{"date-parts":[[2017,3]]},"DOI":"10.1111\/ina.12318","type":"journal-article","created":{"date-parts":[[2016,6,29]],"date-time":"2016-06-29T08:12:18Z","timestamp":1467187938000},"page":"409-416","source":"Crossref","is-referenced-by-count":96,"title":["Development and evaluation of an ultrasonic personal aerosol sampler"],"prefix":"10.1155","volume":"27","author":[{"given":"J.","family":"Volckens","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering; Colorado State University; Fort Collins CO USA"},{"name":"Department of Environmental and Radiological Health Sciences; Colorado State University; Fort Collins CO USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Quinn","sequence":"additional","affiliation":[{"name":"Department of Environmental and Radiological Health Sciences; Colorado State University; Fort Collins CO USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.","family":"Leith","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering; Colorado State University; Fort Collins CO USA"},{"name":"Department of Environmental Sciences and Engineering; University of North Carolina at Chapel Hill; Chapel Hill NC USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Mehaffy","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering; Colorado State University; Fort Collins CO USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C. S.","family":"Henry","sequence":"additional","affiliation":[{"name":"Department of Chemistry; Colorado State University; Fort Collins CO USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.","family":"Miller-Lionberg","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering; Colorado State University; Fort Collins CO USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2016,7,20]]},"reference":[{"key":"10.1111\/ina.12318-BIB0001|ina12318-cit-0001","unstructured":"Institute for Health Metrics and Evaluation (IHME) Seattle, WA IHME, University of Washington 2015 http:\/\/vizhub.healthdata.org\/gbd-compare"},{"key":"10.1111\/ina.12318-BIB0002|ina12318-cit-0002","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1038\/sj.jea.7500378","article-title":"Influence of ambient (outdoor) sources on residential indoor and personal PM2. 5 concentrations: analyses of RIOPA data","volume":"15","author":"Meng","year":"2005","journal-title":"J Expo Sci Environ Epidemiol"},{"key":"10.1111\/ina.12318-BIB0003|ina12318-cit-0003","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1038\/sj.jes.7500483","article-title":"Estimation of ambient and non-ambient components of particulate matter exposure from a personal monitoring panel study","volume":"16","author":"Wilson","year":"2006","journal-title":"J Expo Sci Environ Epidemiol"},{"key":"10.1111\/ina.12318-BIB0004|ina12318-cit-0004","doi-asserted-by":"crossref","first-page":"1133","DOI":"10.1080\/10473289.2000.10464159","article-title":"Personal exposure to fine particulate matter in elderly subjects: relation between personal, indoor, and outdoor concentrations","volume":"50","author":"Janssen","year":"2000","journal-title":"J Air Waste Manag Assoc"},{"key":"10.1111\/ina.12318-BIB0005|ina12318-cit-0005","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1038\/jes.2015.68","article-title":"The Fort Collins Commuter Study: impact of route type and transport mode on personal exposure to multiple air pollutants","volume":"26","author":"Good","year":"2016","journal-title":"J Expo Sci Environ Epidemiol"},{"key":"10.1111\/ina.12318-BIB0006|ina12318-cit-0006","unstructured":"Rappaport S Kupper LL Quantitative exposure assessment, S. Rappaport 2008 https:\/\/www.amazon.com\/Quantitative-Exposure-Assessment-Lawrence-Rappaport\/dp\/B001QJ73QI http:\/\/www.lulu.com\/shop\/stephen-rappaport-and-lawrence-kupper\/quantitative-exposure-assessment\/hardcover\/product-16044080.html"},{"key":"10.1111\/ina.12318-BIB0007|ina12318-cit-0007","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1016\/j.atmosenv.2005.08.042","article-title":"Continuous weeklong measurements of personal exposures and indoor concentrations of fine particles for 37 health-impaired North Carolina residents for up to four seasons","volume":"40","author":"Wallace","year":"2006","journal-title":"Atmos Environ"},{"key":"10.1111\/ina.12318-BIB0008|ina12318-cit-0008","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1289\/ehp.0901634","article-title":"Exposure science: a view of the past and milestones for the future","volume":"118","author":"Lioy","year":"2010","journal-title":"Environ Health Perspect"},{"key":"10.1111\/ina.12318-BIB0009|ina12318-cit-0009","volume-title":"Particle Size-Selective Sampling for Particulate Air Contaminants","author":"Vincent","year":"1999"},{"key":"10.1111\/ina.12318-BIB0010|ina12318-cit-0010","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/0924-4247(96)80097-5","article-title":"Working principle and performance of the dynamic micropump","volume":"50","author":"Gerlach","year":"1995","journal-title":"Sens Actuators, A"},{"key":"10.1111\/ina.12318-BIB0011|ina12318-cit-0011","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/0924-4247(93)80213-Z","article-title":"A valveless diffuser\/nozzle-based fluid pump","volume":"39","author":"Stemme","year":"1993","journal-title":"Sens Actuators, A"},{"key":"10.1111\/ina.12318-BIB0012|ina12318-cit-0012","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/S0924-4247(98)00058-2","article-title":"The piezoelectric valve-less pump-performance enhancement analysis","volume":"69","author":"Ullmann","year":"1998","journal-title":"Sens Actuators, A"},{"key":"10.1111\/ina.12318-BIB0013|ina12318-cit-0013","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1016\/S0021-8502(96)00455-7","article-title":"Characterization and modelling of a family of cyclone aerosol preseparators","volume":"28","author":"Kenny","year":"1997","journal-title":"J Aerosol Sci"},{"key":"10.1111\/ina.12318-BIB0014|ina12318-cit-0014","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1080\/713834411","article-title":"Correction","volume":"32","author":"Kenny","year":"2000a","journal-title":"Aerosol Sci Technol"},{"key":"10.1111\/ina.12318-BIB0015|ina12318-cit-0015","doi-asserted-by":"crossref","first-page":"1407","DOI":"10.1016\/S0021-8502(00)00047-1","article-title":"A direct approach to the design of cyclones for aerosol-monitoring applications","volume":"31","author":"Kenny","year":"2000b","journal-title":"J Aerosol Sci"},{"key":"10.1111\/ina.12318-BIB0016|ina12318-cit-0016","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1080\/027868200303669","article-title":"Development of a sharp-cut cyclone for ambient aerosol monitoring applications","volume":"32","author":"Kenny","year":"2000","journal-title":"Aerosol Sci Technol"},{"key":"10.1111\/ina.12318-BIB0017|ina12318-cit-0017","unstructured":"USEPA Ambient air monitoring reference and equivalent methods, United States Environmental Protection Agency, Federal Register 1997 https:\/\/www.gpo.gov\/fdsys\/pkg\/FR-1997-07-18\/pdf\/97-18579.pdf"},{"key":"10.1111\/ina.12318-BIB0018|ina12318-cit-0018","unstructured":"USEPA Ambient air monitoring reference and equivalent methods, Federal Register 77 FR 55832 2012 https:\/\/federalregister.gov\/a\/2012-22343"},{"key":"10.1111\/ina.12318-BIB0019|ina12318-cit-0019","volume-title":"Aerosol Technology: Properties, Behavior, and Measurement of Airborne Particles","author":"Hinds","year":"1999"},{"key":"10.1111\/ina.12318-BIB0020|ina12318-cit-0020","unstructured":"USEPA National ambient air quality standards for particulate matter, Vol. 78 FR 3086 2013 https:\/\/federalregister.gov\/a\/2012-30946"},{"key":"10.1111\/ina.12318-BIB0021|ina12318-cit-0021","unstructured":"WHO Ambient (outdoor) air quality and health 2014"},{"key":"10.1111\/ina.12318-BIB0022|ina12318-cit-0022","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.1016\/S1352-2310(02)01016-6","article-title":"A closure study of aerosol mass concentration measurements: comparison of values obtained with filters and by direct measurements of mass distributions","volume":"37","author":"Park","year":"2003","journal-title":"Atmos Environ"},{"key":"10.1111\/ina.12318-BIB0023|ina12318-cit-0023","doi-asserted-by":"crossref","first-page":"4613","DOI":"10.1021\/es020711s","article-title":"Filter and electrostatic samplers for semivolatile aerosols: physical artifacts","volume":"36","author":"Volckens","year":"2002","journal-title":"Environ Sci Technol"},{"key":"10.1111\/ina.12318-BIB0024|ina12318-cit-0024","doi-asserted-by":"crossref","unstructured":"Fahrni T Kuhn M Sommer P Wattenhofer R Welten S Sundroid: solar radiation awareness with smartphones 2011 365 374","DOI":"10.1145\/2030112.2030162"},{"key":"10.1111\/ina.12318-BIB0025|ina12318-cit-0025","doi-asserted-by":"crossref","first-page":"349","DOI":"10.3758\/BF03195388","article-title":"Measuring daily behavior using ambulatory accelerometry: the Activity Monitor","volume":"33","author":"Bussmann","year":"2001","journal-title":"Behav Res Methods Instrum Comput"},{"key":"10.1111\/ina.12318-BIB0026|ina12318-cit-0026","doi-asserted-by":"crossref","first-page":"e0137789","DOI":"10.1371\/journal.pone.0137789","article-title":"Laboratory evaluation of the Shinyei PPD42NS low-cost particulate matter sensor","volume":"10","author":"Austin","year":"2015","journal-title":"PLoS ONE"},{"key":"10.1111\/ina.12318-BIB0027|ina12318-cit-0027","doi-asserted-by":"crossref","first-page":"1063","DOI":"10.1080\/02786826.2015.1100710","article-title":"Laboratory evaluation and calibration of three low-cost particle sensors for particulate matter measurement","volume":"49","author":"Wang","year":"2015","journal-title":"Aerosol Sci Technol"},{"key":"10.1111\/ina.12318-BIB0028|ina12318-cit-0028","doi-asserted-by":"crossref","first-page":"3329","DOI":"10.1016\/j.atmosenv.2004.03.007","article-title":"Performance evaluation of the active-flow personal DataRAM PM2.5 mass monitor (Thermo Anderson pDR-1200) designed for continuous personal exposure measurements","volume":"38","author":"Chakrabarti","year":"2004","journal-title":"Atmos Environ"},{"key":"10.1111\/ina.12318-BIB0029|ina12318-cit-0029","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1080\/15459620802009919","article-title":"Evaluation of the pDR-1200 real-time aerosol monitor","volume":"5","author":"Benton-Vitz","year":"2008","journal-title":"J Occup Environ Hyg"},{"key":"10.1111\/ina.12318-BIB0030|ina12318-cit-0030","doi-asserted-by":"publisher","DOI":"10.1111\/ina.12281","article-title":"A comparative study of human exposures to household air pollution from commonly used cookstoves in Sri Lanka","author":"Chartier","year":"2016","journal-title":"Indoor Air"},{"key":"10.1111\/ina.12318-BIB0031|ina12318-cit-0031","doi-asserted-by":"crossref","first-page":"3594","DOI":"10.1016\/j.atmosenv.2011.03.064","article-title":"Impact of time-activity patterns on personal exposure to black carbon","volume":"45","author":"Dons","year":"2011","journal-title":"Atmos Environ"},{"key":"10.1111\/ina.12318-BIB0032|ina12318-cit-0032","volume-title":"Procedure for the determination of particulate matter (PM) mass collection on filters","author":"CARB","year":"2011"},{"key":"10.1111\/ina.12318-BIB0033|ina12318-cit-0033","first-page":"413","article-title":"Rapid detection of transition metals in welding fumes using paper-based analytical devices","volume":"58","author":"Cate","year":"2014","journal-title":"Ann Occup Hyg"},{"key":"10.1111\/ina.12318-BIB0034|ina12318-cit-0034","doi-asserted-by":"crossref","first-page":"1874","DOI":"10.1039\/C5AN02572A","article-title":"Paper-based analytical devices for environmental analysis","volume":"141","author":"Meredith","year":"2016","journal-title":"Analyst"},{"key":"10.1111\/ina.12318-BIB0035|ina12318-cit-0035","doi-asserted-by":"crossref","first-page":"3555","DOI":"10.1021\/ac5000224","article-title":"Multilayer paper-based device for colorimetric and electrochemical quantification of metals","volume":"86","author":"Rattanarat","year":"2014","journal-title":"Anal Chem"},{"key":"10.1111\/ina.12318-BIB0036|ina12318-cit-0036","doi-asserted-by":"crossref","first-page":"4481","DOI":"10.1016\/j.atmosenv.2011.05.030","article-title":"A cellphone based system for large-scale monitoring of black carbon","volume":"45","author":"Ramanathan","year":"2011","journal-title":"Atmos Environ"}],"container-title":["Indoor Air"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fina.12318","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fina.12318","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/onlinelibrary.wiley.com\/wol1\/doi\/10.1111\/ina.12318\/fullpdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,29]],"date-time":"2022-12-29T16:57:19Z","timestamp":1672333039000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/ina.12318"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,7,20]]},"references-count":36,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2017,3]]}},"URL":"https:\/\/doi.org\/10.1111\/ina.12318","archive":["Portico"],"relation":{},"ISSN":["0905-6947"],"issn-type":[{"value":"0905-6947","type":"print"}],"subject":[],"published":{"date-parts":[[2016,7,20]]}}}