{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T02:41:13Z","timestamp":1783651273541,"version":"3.55.0"},"reference-count":32,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2018,7,9]],"date-time":"2018-07-09T00:00:00Z","timestamp":1531094400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2018,7,9]],"date-time":"2018-07-09T00:00:00Z","timestamp":1531094400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100004663","name":"Ministry of Science and Technology, Taiwan","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004663","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Institute of Labor, Occupational Safety and Health, Ministry of Labor, Taiwan"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Indoor Air"],"published-print":{"date-parts":[[2018,9]]},"DOI":"10.1111\/ina.12475","type":"journal-article","created":{"date-parts":[[2018,6,1]],"date-time":"2018-06-01T06:59:59Z","timestamp":1527836399000},"page":"754-762","source":"Crossref","is-referenced-by-count":73,"title":["Relative survival of <i>Bacillus subtilis<\/i>\n spores loaded on filtering facepiece respirators after five decontamination methods"],"prefix":"10.1155","volume":"28","author":[{"given":"T.-H.","family":"Lin","sequence":"first","affiliation":[{"name":"Department of Dental Hygiene; China Medical University; Taichung Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F.-C.","family":"Tang","sequence":"additional","affiliation":[{"name":"Department of Occupational Medicine; Changhua Christian Hospital; Changhua Taiwan"},{"name":"Department of Leisure Services Management; Chaoyang University of Technology; Taichung Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.-C.","family":"Hung","sequence":"additional","affiliation":[{"name":"Institute of Labor, Occupational Safety and Health; Ministry of Labor; New Taipei City Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Z.-C.","family":"Hua","sequence":"additional","affiliation":[{"name":"Department of Occupational Safety and Health; Chung Shan Medical University; Taichung Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4365-8673","authenticated-orcid":false,"given":"C.-Y.","family":"Lai","sequence":"additional","affiliation":[{"name":"Department of Occupational Safety and Health; Chung Shan Medical University; Taichung Taiwan"},{"name":"Department of Occupational Medicine; Chung Shan Medical University Hospital; Taichung Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2018,7,9]]},"reference":[{"key":"10.1111\/ina.12475-BIB0001|ina12475-cit-0001","unstructured":"National Institute for Occupational Safety and Health (NIOSH) Recommended guidance for extended use and limited reuse of N95 filtering facepiece respirators in healthcare settings 2014"},{"key":"10.1111\/ina.12475-BIB0002|ina12475-cit-0002","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1111\/j.1600-0668.1998.00002.x","article-title":"Framework for evaluating measures to control nosocomial tuberculosis transmission","volume":"8","author":"Nazaroff","year":"1998","journal-title":"Indoor Air"},{"key":"10.1111\/ina.12475-BIB0003|ina12475-cit-0003","doi-asserted-by":"crossref","first-page":"e1003205","DOI":"10.1371\/journal.ppat.1003205","article-title":"Influenza virus aerosols in human exhaled breath: particle size, culturability, and effect of surgical masks","volume":"9","author":"Milton","year":"2013","journal-title":"PLoS Pathog"},{"key":"10.1111\/ina.12475-BIB0004|ina12475-cit-0004","doi-asserted-by":"crossref","first-page":"S42","DOI":"10.1093\/cid\/civ141","article-title":"Potential demand for respirators and surgical masks during a hypothetical influenza pandemic in the United States","volume":"60","author":"Carias","year":"2015","journal-title":"Clin Infect Dis"},{"key":"10.1111\/ina.12475-BIB0005|ina12475-cit-0005","doi-asserted-by":"crossref","first-page":"D115","DOI":"10.1080\/15459624.2014.902954","article-title":"Considerations for recommending extended use and limited reuse of filtering facepiece respirators in health care settings","volume":"11","author":"Fisher","year":"2014","journal-title":"J Occup Environ Hyg"},{"key":"10.1111\/ina.12475-BIB0006|ina12475-cit-0006","doi-asserted-by":"crossref","first-page":"24","DOI":"10.2307\/30141959","article-title":"Does a cheaper mask save money? The cost implementing a respiratory personal protective equipment program","volume":"18","author":"Rivera","year":"1997","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1111\/ina.12475-BIB0007|ina12475-cit-0007","volume-title":"Reusability of Facemasks During an Influenza Pandemic: Facing the Flu","author":"IOM","year":"2006"},{"key":"10.1111\/ina.12475-BIB0008|ina12475-cit-0008","unstructured":"Lin CS FDA regulation of surgical masks and respirators 2006 http:\/\/www.iom.edu\/~\/media\/Files\/ActivityFiles\/PublicHealth\/ReusableFluMasks\/FDApresentation12306.ashx"},{"key":"10.1111\/ina.12475-BIB0009|ina12475-cit-0009","unstructured":"Occupational Safety and Health Administration Cleaning and decontamination of ebola on surfaces. Guidance for workers and employers in non-healthcare\/non-laboratory settings https:\/\/www.osha.gov\/Publications\/OSHA_FS-3756.pdf"},{"key":"10.1111\/ina.12475-BIB0010|ina12475-cit-0010","unstructured":"Occupational Safety and Health Administration Decontamination https:\/\/www.osha.gov\/SLTC\/hazardouswaste\/training\/decon.html"},{"key":"10.1111\/ina.12475-BIB0011|ina12475-cit-0011","first-page":"93","article-title":"Effect of decontamination on the filtration efficiency of two filtering facepiece respirator models","volume":"24","author":"Viscusi","year":"2007","journal-title":"J Int Soc Resp Prot"},{"key":"10.1111\/ina.12475-BIB0012|ina12475-cit-0012","first-page":"815","article-title":"Evaluation of five decontamination methods for filtering facepiece respirators","volume":"53","author":"Viscusi","year":"2009","journal-title":"Ann Occup Hyg"},{"key":"10.1111\/ina.12475-BIB0013|ina12475-cit-0013","first-page":"33","article-title":"Evaluation of multiple (3-cycle) decontamination processing for filtering facepiece respirators","volume":"4","author":"Bergman","year":"2010","journal-title":"JEFF"},{"key":"10.1111\/ina.12475-BIB0014|ina12475-cit-0014","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1080\/15459624.2011.585927","article-title":"Impact of three biological decontamination methods on filtering facepiece respirator fit, odor, comfort, and donning ease","volume":"8","author":"Viscusi","year":"2011","journal-title":"J Occup Environ Hyg"},{"key":"10.1111\/ina.12475-BIB0015|ina12475-cit-0015","unstructured":"Rutala WA Weber DJ The Healthcare Infection Control Practices Advisory Committee (HICPAC) Guideline for disinfection and sterilization in healthcare facilities 2008"},{"key":"10.1111\/ina.12475-BIB0016|ina12475-cit-0016","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1080\/15459624.2010.484794","article-title":"Analysis of residual chemical on filtering facepiece respirators after decontamination","volume":"7","author":"Salter","year":"2010","journal-title":"J Occup Environ Hyg"},{"key":"10.1111\/ina.12475-BIB0017|ina12475-cit-0017","first-page":"92","article-title":"Effectiveness of three decontamination treatments against influenza virus applied to filtering facepiece respirators","volume":"56","author":"Lore","year":"2012","journal-title":"Ann Occup Hyg"},{"key":"10.1111\/ina.12475-BIB0018|ina12475-cit-0018","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1111\/j.1365-2672.2010.04881.x","article-title":"A method to determine the available UV-C dose for the decontamination of filtering facepiece respirators","volume":"110","author":"Fisher","year":"2010","journal-title":"J Appl Microbial"},{"key":"10.1111\/ina.12475-BIB0019|ina12475-cit-0019","unstructured":"Food and Drug Administration FDA-cleared sterilants and high level disinfectants with general claims for processing reusable medical and dental devices 2015"},{"key":"10.1111\/ina.12475-BIB0020|ina12475-cit-0020","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1080\/15428119891010488","article-title":"The effects of particle charge on the performance of a filtering facepiece","volume":"59","author":"Chen","year":"1998","journal-title":"Am Ind Hyg Assoc J"},{"key":"10.1111\/ina.12475-BIB0021|ina12475-cit-0021","doi-asserted-by":"crossref","first-page":"187","DOI":"10.4209\/aaqr.2015.03.0196","article-title":"Recovery of bacteria in filtering facepiece respirators and effects of artificial saliva\/perspiration on bacterial survival and performance of respirators","volume":"17","author":"Lin","year":"2017","journal-title":"Aerosol Air Qual Res"},{"key":"10.1111\/ina.12475-BIB0022|ina12475-cit-0022","doi-asserted-by":"crossref","first-page":"e0186217","DOI":"10.1371\/journal.pone.0186217","article-title":"Filter quality of electret masks in filtering 14.6-594\u00a0nm aerosol particles: Effects of five decontamination methods","volume":"12","author":"Lin","year":"2017","journal-title":"PLoS ONE"},{"key":"10.1111\/ina.12475-BIB0023|ina12475-cit-0023","doi-asserted-by":"crossref","first-page":"1218","DOI":"10.1016\/j.ajic.2013.02.017","article-title":"Physiologic and other effects and compliance with long-term respirator use among medical intensive care unit nurses","volume":"41","author":"Rebmann","year":"2013","journal-title":"Am J Infect Control"},{"key":"10.1111\/ina.12475-BIB0024|ina12475-cit-0024","unstructured":"Respiratory protection devices: final rule and notice 1995 60 30336 30404"},{"key":"10.1111\/ina.12475-BIB0025|ina12475-cit-0025","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1086\/670225","article-title":"Challenge of N95 filtering facepiece respirators with viable H1N1 influenza aerosols","volume":"34","author":"Harnish","year":"2013","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1111\/ina.12475-BIB0026|ina12475-cit-0026","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1080\/027868299304705","article-title":"Evaluation of microbial samplers for bacterial microorganisms","volume":"30","author":"Li","year":"1999","journal-title":"Aerosol Sci Technol"},{"key":"10.1111\/ina.12475-BIB0027|ina12475-cit-0027","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1080\/02786828208958584","article-title":"Theoretical study of aerosol filtration by fibrous filters","volume":"1","author":"Lee","year":"1982","journal-title":"Aerosol Sci Technol"},{"key":"10.1111\/ina.12475-BIB0028|ina12475-cit-0028","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1080\/02786829808965542","article-title":"The effect of sampling time and flow rates on the bioefficiency of three fungal spore sampling methods","volume":"28","author":"Lin","year":"1998","journal-title":"Aerosol Sci Technol"},{"key":"10.1111\/ina.12475-BIB0029|ina12475-cit-0029","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1080\/15428110308984798","article-title":"Influence of storage on the fungal concentration determination of impinger and filter samples","volume":"64","author":"Lin","year":"2003","journal-title":"Am Ind Hyg Assoc J"},{"key":"10.1111\/ina.12475-BIB0030|ina12475-cit-0030","volume-title":"Laboratory Biosafety Manual","author":"World Health Organization","year":"2004"},{"key":"10.1111\/ina.12475-BIB0031|ina12475-cit-0031","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1080\/027868299304651","article-title":"Survival of bacteria on respirator filters","volume":"30","author":"Wang","year":"1999","journal-title":"Aerosol Sci Technol"},{"key":"10.1111\/ina.12475-BIB0032|ina12475-cit-0032","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1016\/S0196-6553(96)90024-3","article-title":"Comparative sporicidal effect of liquid chemical germicides on three medical devices contaminated with spores of Bacillus subtilis","volume":"24","author":"Sagripanti","year":"1996","journal-title":"Am J Infect Control"}],"container-title":["Indoor Air"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fina.12475","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/onlinelibrary.wiley.com\/wol1\/doi\/10.1111\/ina.12475\/fullpdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,29]],"date-time":"2022-12-29T16:58:05Z","timestamp":1672333085000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/ina.12475"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7,9]]},"references-count":32,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018,9]]}},"URL":"https:\/\/doi.org\/10.1111\/ina.12475","archive":["Portico"],"relation":{},"ISSN":["0905-6947"],"issn-type":[{"value":"0905-6947","type":"print"}],"subject":[],"published":{"date-parts":[[2018,7,9]]}}}