{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T07:26:31Z","timestamp":1767165991537,"version":"build-2238731810"},"reference-count":26,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2024,3,28]],"date-time":"2024-03-28T00:00:00Z","timestamp":1711584000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["International Wound Journal"],"published-print":{"date-parts":[[2024,4]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Peritoneal dialysis(PD) is one of the most efficient methods in end\u2010stage kidney disease, and it is very important for PD to perform well. No research has been conducted to evaluate the effect of various types of PD catheters on the prognosis of post\u2010operative wound complications. While recent meta\u2010analyses are in favour of straight tubing, there is still uncertainty as to whether direct or coiled PD is beneficial. The purpose of this meta\u2010analysis was to compare the efficacy of direct and coiled PD catheters on the incidence of post\u2010operative wound infection, bleeding and peritonitis. A comprehensive search was carried out on three databases, including PubMed and Embase, and a manual search was carried out on the links in the paper. The results showed that the incidence rate of bleeding after operation and the degree of infection among the straight and coiled pipes were compared. The results showed that there were no statistically significant differences in the incidence of post\u2010operative wound infection among straight PD patients with coiled PD (OR, 0.79; 95% CI, 0.58\u20131.08\n                    <jats:italic>p<\/jats:italic>\n                    \u2009=\u20090.13). No statistical significance was found in the case of PD with coiled tubing compared with that of straight PD group in wound leakage (OR, 1.17; 95% CI, 0.71\u20131.93\n                    <jats:italic>p<\/jats:italic>\n                    \u2009=\u20090.55). No statistically significantly different rates of post\u2010operative peritonitis were observed for coiled tubing compared with straight ones in PD patients (OR, 1.06; 95% CI, 0.78\u20131.45\n                    <jats:italic>p<\/jats:italic>\n                    \u2009=\u20090.7). There is no statistical significance on the rate of wound infection, wound leakage and peritonitis among coiled and straight tube in PD.\n                  <\/jats:p>","DOI":"10.1111\/iwj.14800","type":"journal-article","created":{"date-parts":[[2024,3,28]],"date-time":"2024-03-28T08:10:38Z","timestamp":1711613438000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["RETRACTED: Effect of two different peritoneal dialysis modalities on wound infection in peritoneal dialysis patients: A meta\u2010analysis"],"prefix":"10.1111","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-8905-8500","authenticated-orcid":false,"given":"Li","family":"Tang","sequence":"first","affiliation":[{"name":"Zigong Third People's Hospital  Zigong China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qijun","family":"Cheng","sequence":"additional","affiliation":[{"name":"Zigong First People's Hospital  Zigong China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yonghong","family":"Qing","sequence":"additional","affiliation":[{"name":"Fushun County Hospital of Chinese Medicine  Zigong China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jie","family":"Yu","sequence":"additional","affiliation":[{"name":"Fushun County People's Hospital  Zigong China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaoping","family":"Yan","sequence":"additional","affiliation":[{"name":"Zigong Third People's Hospital  Zigong China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Changbin","family":"Liao","sequence":"additional","affiliation":[{"name":"Zigong Third People's Hospital  Zigong China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2024,3,28]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.ASN.0000091585.45723.9E"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1681\/ASN.V86965"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1177\/089686080502500115"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1093\/ndt\/gfp447"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.3747\/pdi.2010.00087"},{"key":"e_1_2_9_7_1","first-page":"ix8","article-title":"European best practice guidelines for peritoneal dialysis. 3 peritoneal access","volume":"20","author":"Dombros N","year":"2005","journal-title":"Nephrol Dial Transplant"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1038\/ki.2013.365"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2011.06.026"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.3747\/pdi.2013.00016"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1177\/089686080502500204"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.4103\/ijn.ijn_176_21"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1177\/089686089001000117"},{"issue":"3","key":"e_1_2_9_14_1","first-page":"169","article-title":"A comparative study on using coiled versus straight swan\u2010neck Tenckhoff catheters in patients undergoing peritoneal dialysis","volume":"33","author":"Hekmat R","year":"2008","journal-title":"Iran J Med Sci"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.3747\/pdi.2011.000298"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2006.08.010"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1177\/089686080302302s26"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1177\/089686089601601S64"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1177\/089686089501500104"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.4103\/ijn.ijn_158_21"},{"key":"e_1_2_9_21_1","first-page":"147","article-title":"Current trends in the use of peritoneal dialysis catheters","volume":"22","author":"Negoi D","year":"2006","journal-title":"Adv Peritoneal Dialysis Conference Peritoneal Dialysis"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1177\/089686089501500412"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1177\/089686089401400114"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1177\/089686089401400320"},{"issue":"3","key":"e_1_2_9_25_1","first-page":"M497","article-title":"A prospective randomized evaluation of chronic peritoneal catheters. Insertion site and intraperitoneal segment","volume":"36","author":"Rubin J","year":"1990","journal-title":"ASAIO Trans"},{"issue":"3","key":"e_1_2_9_26_1","first-page":"S59","article-title":"The CARI guidelines. Evidence for peritonitis treatment and prophylaxis: type of peritoneal dialysis catheter","volume":"9","author":"Caring for Australians with Renal I","year":"2004","journal-title":"Nephrology (Carlton)"},{"key":"e_1_2_9_27_1","article-title":"Catheter type, placement and insertion techniques for preventing peritonitis in peritoneal dialysis patients","volume":"4","author":"Strippoli GF","year":"2004","journal-title":"Cochrane Database Syst Rev"}],"updated-by":[{"DOI":"10.1111\/iwj.70411","type":"retraction","label":"Retraction","source":"retraction-watch","updated":{"date-parts":[[2025,3,21]],"date-time":"2025-03-21T00:00:00Z","timestamp":1742515200000},"record-id":"65484"},{"DOI":"10.1111\/iwj.70411","type":"retraction","label":"Retraction","source":"publisher","updated":{"date-parts":[[2025,3,21]],"date-time":"2025-03-21T00:00:00Z","timestamp":1742515200000}}],"container-title":["International Wound Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/iwj.14800","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,4]],"date-time":"2025-08-04T06:29:05Z","timestamp":1754288945000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/iwj.14800"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,28]]},"references-count":26,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024,4]]}},"alternative-id":["10.1111\/iwj.14800"],"URL":"https:\/\/doi.org\/10.1111\/iwj.14800","archive":["Portico"],"relation":{},"ISSN":["1742-4801","1742-481X"],"issn-type":[{"value":"1742-4801","type":"print"},{"value":"1742-481X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3,28]]},"assertion":[{"value":"2024-01-19","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-02-04","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-03-28","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e14800"}}