{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T14:58:20Z","timestamp":1770821900166,"version":"3.50.1"},"reference-count":14,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2004,5,20]],"date-time":"2004-05-20T00:00:00Z","timestamp":1085011200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Anaesthesiol Scand"],"published-print":{"date-parts":[[2004,7]]},"abstract":"<jats:p><jats:bold>Background:\u2002<\/jats:bold> Insertion of central venous catheters (CVCs) is a procedure associated with a varying risk of complications, depending on the setting and the skill of the clinician who undertakes the procedure. The aim of this study was to monitor the complication rate of CVC insertion and evaluate the value of routine chest X\u2010ray control.<\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold> Anesthesiologists at eight hospitals filled in a questionnaire immediately after insertion of a CVC. The post\u2010procedural clinical evaluation, including expected complications, was compared to actual radiological findings. Chest X\u2010ray was ordered by the anesthesiologist, and described by staff radiologists.<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold> The clinicians had from 2\u2003months to 30\u2003years of experience as anesthesiologists, and trainees inserted 34% and specialists 66% of the catheters, using landmark techniques. Over a period of 2\u2003months, 473 CVC\u2010insertion procedures were included in the investigation.Two patients (0.4%) had a pneumothorax: one was among the 11 cases in which the clinician suspected complications after the procedure, and another was found in a high\u2010risk patient 13\u2003h after CVC insertion. Both patients were treated successfully with chest tubes.The favorite approach was right vena jugularis interna with 324 (69%) catheters; of these patients one had a pneumothorax, catheter\u2010tip placement was correctly predicted in 317 (97%), and no catheters were repositioned.<\/jats:p><jats:p><jats:bold>Conclusion:\u2002<\/jats:bold> In the hands of trained clinicians, insertion of CVCs is a safe procedure. We found no value of routine X\u2010ray control and omission of routine chest X\u2010ray must be considered.<\/jats:p>","DOI":"10.1111\/j.0001-5172.2004.00400.x","type":"journal-article","created":{"date-parts":[[2004,6,11]],"date-time":"2004-06-11T15:51:24Z","timestamp":1086969084000},"page":"685-689","source":"Crossref","is-referenced-by-count":32,"title":["Routine X\u2010ray control of upper central venous lines: Is it necessary?"],"prefix":"10.1111","volume":"48","author":[{"given":"O.","family":"Molgaard","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M. S.","family":"Nielsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B. B.","family":"Handberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. M.","family":"Jensen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Kjaergaard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N.","family":"Juul","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2004,5,20]]},"reference":[{"issue":"1","key":"e_1_2_7_2_2","first-page":"1","volume":"21","author":"ICRP publication 60.","year":"1990","journal-title":"Ann ICRP"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0272-6386(97)90494-7"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9610(00)00498-0"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1053\/jcan.2001.28307"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-199211000-00006"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-199909000-00019"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/85.2.188"},{"key":"e_1_2_7_9_2","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1177\/014107689709000607","article-title":"Complications of 1303 central venous cannulations","volume":"90","author":"Yilmazla A","year":"1997","journal-title":"J Roy Soc Med"},{"key":"e_1_2_7_10_2","first-page":"319","article-title":"Complications and failures of subclavian\u2010vien catheterization","volume":"90","author":"Mansfield PF","year":"1994","journal-title":"N Engl J Med"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-199308000-00008"},{"key":"e_1_2_7_12_2","first-page":"459","article-title":"Cardiac tamponade caused by central venous catheter perforation of the heart: a preventable complication","volume":"181","author":"Collier PE","year":"1995","journal-title":"J Am Coll Surg"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X9802600109"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.101.6.1633"},{"key":"e_1_2_7_15_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00134-001-1154-9","article-title":"Central venous catheter use. Part 1: mecanical complications","volume":"28","author":"Polderman KH","year":"2002","journal-title":"Intensive Care Med"}],"container-title":["Acta Anaesthesiologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.0001-5172.2004.00400.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.0001-5172.2004.00400.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,13]],"date-time":"2023-10-13T13:12:52Z","timestamp":1697202772000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.0001-5172.2004.00400.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,5,20]]},"references-count":14,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2004,7]]}},"alternative-id":["10.1111\/j.0001-5172.2004.00400.x"],"URL":"https:\/\/doi.org\/10.1111\/j.0001-5172.2004.00400.x","archive":["Portico"],"relation":{},"ISSN":["0001-5172","1399-6576"],"issn-type":[{"value":"0001-5172","type":"print"},{"value":"1399-6576","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,5,20]]}}}